Output Event Types
There are approximately fifty different output event types to choose from. Two numbers
designate each output event type. These two numbers need to be programmed into the
appropriate locations of the output being used to indicate when the output should operate.
All reset times are in reference to polarity 1 and 8. Reset times will vary depending on
the polarity used.
00
EDMSAT - Satellite Siren (Output 1 Only)
This output controls all functions of an EDMSAT satellite siren (SS914). The
option of speaker indication beeps will not operate via the EDMSAT for remote
operations. No polarity is required to be programmed for this output event type.
00
EDMSTU – Securitel PCB (Output 2 - Only )
This output controls all functions of an EDMSTU Securitel unit (CS800). The Data
terminal on the securitel unit connects to the STR terminal on the control panel. No
polarity is required to be programmed for this output event type.
01
System Armed
This output will operate when the system is armed in AWAY Mode or STAY Mode.
The output will reset when the system has been disarmed.
02
System Disarmed
This output will operate when the system is in the disarmed state. The output will
reset as soon as the system becomes armed.
03
Armed In STAY Mode
This output will operate when the system has been armed in STAY Mode. The
output will reset when the system is disarmed.
04
Armed In AWAY Mode
This output will operate when the system has been armed in AWAY Mode. The
output will reset when the system is disarmed.
06
Exit Warning With All Zones Sealed Or Entry Warning
This output will operate during exit time when the control panel has been armed in
AWAY Mode or STAY Mode if all zones are sealed. This output event type will
reset once exit time has expired.
The next time this output event type will operate will be during entry time and will
reset once entry time has expired or the system has been disarmed. This output
event type will also operate if a zone has triggered when the system has been armed
in STAY Mode only if the “Entry Guard Timer For STAY Mode” has been
programmed in "LOCATION 216 - 217" on page 129.
07
Exit Warning
This output operates during exit time when the system has been armed in AWAY
Mode or STAY Mode. The output will reset once exit time has expired.
08
Exit Warning Finished
This output operates when the exit time has expired when the system has been
armed in AWAY Mode or STAY Mode. The output will reset when the system has
been disarmed.
09
Kiss-Off After End Of Exit Time
This output will operate after the first successful transmission to the base station
receiver when exit time has expired. The output will reset when the system has been
disarmed.
0
Entry Warning
This output will operate when either Entry Timer 1, Entry Timer 2 or Entry Guard
Timer For STAY Mode are operating. The output will reset when the entry time
expires or the system has been disarmed.
118
Solution 4+4
Installation Manual
ISSUE123.DOC
Electronics Design and Manufacturing Pty Limited
Summary of Contents for Solution 4+4
Page 1: ...Solution 4 4 Installation Manual ISSUE 1 23...
Page 2: ......
Page 4: ......
Page 6: ......
Page 13: ...Introduction This section includes the following Introduction Features Quick Start...
Page 89: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 163: ...Programming Sheets...
Page 169: ...Index...
Page 174: ......