124
Troubleshooting
Rebuilding a physical
disk after one of them is
in a failed state.
If you have configured hot spares, the PERC 6 controller
automatically tries to use one of them to rebuild a physical
disk that is in a failed state. Manual rebuild is necessary if
no hot spares with enough capacity to rebuild the failed
physical disks are available. You must insert a physical disk
with enough storage in the subsystem before rebuilding the
physical disk. You can use the BIOS Configuration Utility
or Dell OpenManage storage management application
to
perform a manual rebuild of an individual physical disk.
For information on rebuilding a single physical disk, see
"Performing a Manual Rebuild of an Individual Physical
Disk" on page 108.
A virtual disk fails during
rebuild while using a
global hot spare.
The global hot spare goes back to
Hotspare
state and the
virtual disk goes to
Failed
state.
A virtual disk fails during
rebuild while using a
dedicated hot spare.
The dedicated hot spare goes to
Ready
state and the virtual
disk goes to
Failed
state.
A physical disk fails
during a reconstruction
process on a redundant
virtual disk that has a
hot spare.
The rebuild operation for the
inaccessible
physical disk
starts automatically after the reconstruction is completed.
A physical disk is taking
longer than expected to
rebuild.
A physical disk takes longer to rebuild when under high
stress. For example, there is one rebuild I/O operation for
every five host I/O operations.
You cannot add a second
virtual disk to a disk
group while the virtual
disk in that disk group is
undergoing a rebuild
The firmware does not allow you to create a virtual disk
using the free space available in a disk group if a physical
disk in a virtual disk group is undergoing a rebuild
operation.
Table 7-5.
Physical Disk Failure and Rebuild Issues
(continued)
Issue
Suggested Solution
Dell_PERC6.2_UG.book Page 124 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...
Page 156: ...156 Glossary ...