Troubleshooting
125
SMART Errors
Table 7-6 describes issues related to the Self-Monitoring Analysis and
Reporting Technology (SMART). SMART monitors the internal performance
of all motors, heads, and physical disk electronics and detects predictable
physical disk failures.
NOTE:
For information about where to find reports of SMART errors that could
indicate hardware failure, see the Dell OpenManage storage management
documentation on the Dell Support website at
support.dell.com
.
Table 7-6.
SMART Errors
Problem
Suggested Solution
A SMART error is
detected on a
physical disk in a
redundant virtual
disk.
Perform the following steps:
1
Force the physical disk offline.
NOTE:
If a hot spare is present, the rebuild starts with the hot
spare after the drive is forced offline.
2
Replace it with a new physical disk of equal or higher capacity.
3
Perform the
Replace Member
operation.
The
Replace Member
operation allows you to copy data from
a source physical disk of a virtual disk to a target physical disk
that is not a part of the virtual disk. For more information
about the
Replace Member
feature, see "Using Replace
Member and Revertible Hot Spares" on page 37.
A SMART error is
detected on a
physical disk in a
non-redundant
virtual disk.
Perform the following steps:
1
Back up your data.
2
Use
Replace Member
or set up a global hot spare to replace
the disk automatically.
For more information about the
Replace Member
feature, see
"Using Replace Member and Revertible Hot Spares" on
page 37.
3
Replace the affected physical disk with a new physical disk of
equal or higher capacity.
4
Restore from the backup.
Dell_PERC6.2_UG.book Page 125 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...
Page 156: ...156 Glossary ...