104
Configuring and Managing RAID
Controller Management Actions
Table 6-6 describes the actions you can perform on the
Ctrl Mgmt
screen.
Foreign Configuration View
When a foreign configuration is present, you can select
Foreign
Configuration View
to display the configuration. This screen shows the
foreign configuration as it would be if you import it. You can preview the
foreign configuration before you decide whether to import it or clear it.
In some cases, a foreign configuration cannot be imported. If a physical disk
in a virtual disk is rebuilding, the physical disk's state is set to
Rebuild
. For the
virtual disks, the text
Importable
or
Not Importable
displays next to
each virtual disk. No virtual disk target ID displays for virtual disks that
cannot be imported.
Table 6-6.
Controller Management Options
Option
Description
Enable Controller
BIOS
Select this option to enable the controller BIOS. If the boot
device is on the RAID controller, the BIOS must be enabled.
Disable the BIOS to use other boot devices.
In a multiple controller environment, you can enable BIOS on
multiple controllers. However, if you want to boot from a
specific controller, then enable the BIOS on that controller
and disable it on the other controllers. The system can then
boot from the BIOS-enabled controller.
Enable Alarm
Select this option to enable or disable the audible alarm on
the controller, if alarm hardware is present. The alarm sounds
to warn you of any problems with the physical disks or the
virtual disks.
Enable BIOS Stop
On Error
Select this option to stop the system BIOS during bootup if
there are BIOS errors. This option enables you to enter the
configuration utility to resolve the problem.
Select Bootable VD
Select this option to specify a virtual disk as the boot disk on
the controller.
This option displays if you have built virtual disks.
Factory Default
Select this option to restore the default settings for the
options in the
Settings
box.
Dell_PERC6.2_UG.book Page 104 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...
Page 156: ...156 Glossary ...