38
About PERC 6 and CERC 6/i Controllers
Automatic Replace Member with Predicted Failure
A
Replace Member
operation can occur when there is a SMART predictive
failure reporting on a drive in a virtual disk. The automatic
Replace Member
is initiated when the first SMART error occurs on a physical disk that is part
of a virtual disk. The target drive needs to be a hot spare that qualifies as
a rebuild drive. The physical disk with the SMART error is marked as
failed
only after the successful completion of the
Replace Member
. This avoids
putting the array in degraded status.
If an automatic
Replace Member
occurs using a source drive that was
originally a hot spare (that was used in a rebuild), and a new drive added for
the
Replace Member
operation as the target drive, the hot spare reverts to the
hot spare state after a successful
Replace Member
operation.
NOTE:
To enable the automatic Replace Member, use the Dell OpenManage
storage management application. For more information on automatic Replace
Member, see "Dell OpenManage Storage Management" on page 77.
NOTE:
For information on manual Replace Member, see "Replacing an Online
Physical Disk" on page 107.
Patrol Read
The
Patrol Read
feature is designed as a preventative measure to ensure
physical disk health and data integrity.
Patrol Read
scans for and resolves
potential problems on configured physical disks. The OpenManage storage
management application can be used to start
Patrol Read
and change its
behavior.
Patrol Read Feature
The following is an overview of
Patrol Read
behavior:
1
Patrol Read
runs on all disks on the controller that are configured as part
of a virtual disk, including hot spares.
2
Patrol Read
does not run on physical disks that are not part of a virtual disk
or are in
Ready
state.
Dell_PERC6.2_UG.book Page 38 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...