About PERC 6 and CERC 6/i Controllers
25
A SMART failure is also referred to as a predicted failure. There are numerous
factors that relate to predicted physical disk failures, such as a bearing failure,
a broken read/write head, and changes in spin-up rate. In addition, there are
factors related to read/write surface failure, such as seek error rate
and excessive bad sectors.
For information on physical disk status, see "Disk Roaming" on page 27.
NOTE:
For detailed information on Small Computer System Interface (SCSI)
interface specifications, see
www.t10.org
and for detailed information on for Serial
Attached ATA (SATA) interface specifications, see
www.t13.org
.
Initializing Virtual Disks
You can initialize the virtual disks as described in the following sections.
Background Initialization
Background Initialization (BGI) is an automated process that writes the
parity or mirror data on newly created virtual disks. BGI assumes that the data
is correct on all new drives. BGI does not run on RAID 0 virtual disks.
NOTE:
You cannot permanently disable BGI. If you cancel BGI, it automatically
restarts within five minutes. For information on stopping BGI, see "Stopping
Background Initialization" on page 108.
You can control the BGI rate in the Dell™ OpenManage™ storage
management application. Any change in the BGI rate does not take effect
until the next BGI run.
NOTE:
Unlike full or fast initialization of virtual disks, Background Initialization does
not clear data from the physical disks.
Consistency Check (CC) and BGI perform similar functions in that they
both correct parity errors. However, CC reports data inconsistencies through
an event notification, but BGI does not (BGI assumes the data is correct, as it
is run only on a newly created disk). You can start CC manually, but not BGI.
Dell_PERC6.2_UG.book Page 25 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...
Page 156: ...156 Glossary ...