About PERC 6 and CERC 6/i Controllers
39
3
Patrol Read
adjusts the amount of controller resources dedicated to
Patrol Read
operations based on outstanding disk I/O. For example, if the
system is busy processing I/O operation, then
Patrol Read
uses fewer
resources to allow the I/O to take a higher priority.
4
Patrol Read
does not run on any disks involved in any of the following
operations:
•
Rebuild
•
Replace Member
•
Full or Background Initialization
•
Consistency Check
•
RAID Level Migration or Online Capacity Expansion
Patrol Read Modes
The following describes each of the modes
Patrol Read
can be set to:
•
Auto
(default)
— Patrol Read
is set to the
Auto
mode by default. In this
mode,
Patrol Read
is enabled to run automatically and start every seven
days on SAS and SATA HDDs.
Patrol Read
is not necessary on SSD and is
disabled by default. You can start and stop
Patrol Read
as well.
•
Manual
— Patrol Read
does not run automatically and you must start it
manually.
•
Disabled
— Patrol Read
is not allowed to start on the controller.
Dell_PERC6.2_UG.book Page 39 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...
Page 156: ...156 Glossary ...