About PERC 6 and CERC 6/i Controllers
29
Migrating Virtual Disks from SAS 6/iR to PERC 6 and CERC 6/i
NOTE:
The supported operating systems listed in "Compatibility With Virtual Disks
Created on SAS 6/iR Controllers" on page 28 contain the driver for the PERC 6
and CERC 6/i controller family. No additional drivers are needed during the
migration process.
1
If virtual disks with one of the supported Linux operating systems listed in
"Compatibility With Virtual Disks Created on SAS 6/iR Controllers" on
page 28 are being migrated, open a command prompt and type the
following commands:
modprobe megaraid_sas
mkinitrd -f --preload megaraid_sas /boot/initrd-
`uname -r`.img `uname -r`
2
Turn off the system.
3
Move the appropriate physical disks from the SAS 6/iR controller to the
PERC 6 and CERC 6/i. If you are replacing your SAS 6/iR controller with a
PERC 6 controller, see the
Hardware Owner’s Manual
shipped with your
system or on the Dell Support website at
support.dell.com
.
CAUTION:
After you have imported the foreign configuration on the PERC 6 or
CERC 6/i storage controllers, migrating the storage disks back to the SAS 6/iR
controller may result in the loss of data.
4
Boot the system and import the foreign configuration that is detected.
You can do this in two ways:
•
Press <F> to automatically import the foreign configuration
•
Enter the
BIOS Configuration Utility
and navigate to the
Foreign
Configuration View
NOTE:
For more information on accessing the
BIOS Configuration Utility
,
see "Entering the BIOS Configuration Utility" on page 79
.
NOTE:
For more information on Foreign Configuration View, see "Foreign
Configuration View" on page 104
5
If the migrated virtual disk is the boot volume, ensure that the virtual disk
is selected as the bootable volume for the target PERC 6 and CERC 6/i
controller. See "Controller Management Actions" on page 104.
Dell_PERC6.2_UG.book Page 29 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...