Configuring and Managing RAID
Table 6-2 shows the parameters that you can configure when defining
virtual disks.
Table 6-2.
Virtual Disk Parameters and Descriptions
Parameter
Description
RAID Level
RAID Level
specifies whether the virtual disk is RAID 0, 1, 5,
6, 10, 50, or 60. The RAID level you select depends on the
number of disks, disk capacity, and the requirements for fault
tolerance and performance. More more information, see
"Summary of RAID Levels" on page 17.
Stripe Element Size
Stripe Element Size
specifies the size of the segments written
to each physical disk in a RAID 0, 1, 5, 6, 10, and 50
virtual disk. You can set the stripe element size to
8 KB
,
16 KB
,
32 KB
,
64 KB
,
128 KB
,
256 KB
,
512 KB
, or
1024 KB
. The
default and recommended stripe element size is
64 KB
.
A larger stripe element size provides better read performance if
your system mostly does sequential reads.
Write Policy
Write Policy
specifies the controller write policy. You can set
the write policy to
Write-Back
or
Write-Through
.
In
Write-Back
caching, the controller sends a data transfer
completion signal to the host when the controller cache has
received all the data in a transaction.
NOTE:
If a Battery Backup Unit (BBU) is present, the default
cache setting is
Write-Back
. If no BBU is present, the default
cache policy default setting is
Write-Through
.
NOTE:
If
Write-Back
is enabled and the system is quickly turned
off and then on, the controller may pause as the system flushes
cache memory. Controllers that contain a battery backup default
to
Write-Back
caching.
In
Write-Through
caching, the controller sends a data transfer
completion signal to the host when the disk subsystem has
received all the data in a transaction.
Write-Back
caching has a performance advantage over
Write-Through
caching.
NOTE:
Certain data patterns and configurations perform better
with
Write-Through
cache policy.
Dell_PERC6.2_UG.book Page 84 Wednesday, June 24, 2009 6:08 PM
Summary of Contents for 6 series
Page 1: ...Dell PowerEdge Expandable RAID Controller PERC 6 i PERC 6 E and CERC 6 i User s Guide ...
Page 10: ...10 Contents ...
Page 40: ...40 About PERC 6 and CERC 6 i Controllers ...
Page 62: ...62 Installing and Configuring Hardware ...
Page 112: ...112 Configuring and Managing RAID ...
Page 132: ...132 Troubleshooting ...
Page 134: ...134 Regulatory Notices ...
Page 136: ...136 Corporate Contact Details Taiwan Only ...
Page 156: ...156 Glossary ...