Maintenance and Repair
MagnaTran 7.1 User’s Manual
End Effector Pad Cleaning Procedure
MN-003-1600-00
Brooks Automation
9-16
Revision 2.2
3.
Once all residues have been removed, use dry cleanroom wipes to dry all sur-
faces.
Cleaning Stainless Steel or Quartz Pads Procedure
DANGER
The MagnaTran 7 may be used in an environment where hazardous
materials are present, and surfaces may be contaminated by those
materials. Refer to the facility’s Material Safety Data Sheets for those
materials to determine proper handling.
1.
Dampen a cleanroom wipe with Isopropyl.
CAUTION
Wipe must be moistened only; squeezing the wipe should not cause
any alcohol to drip.
Do not allow alcohol to come in contact with bearings, seals, etc.
2.
Clean the entire end effector, paying special attention to the pads. Do not
apply excessive pressure or force to the pads while cleaning. Excessive force
may bend the end effector.
3.
Once all residues have been removed, use dry cleanroom wipes to dry all sur-
faces.