MagnaTran 7.1 User’s Manual
Maintenance and Repair
MN-003-1600-00
Power Pak Replacement
Brooks Automation
Revision 2.2
9-65
6.
Install power cables.
Install power cable from +24V OUT of Power Pak to +24V IN or the robot inter-
face panel.
Install power cable from the +24VDC power supply to the +24V IN of the
Power Pak. Power supply must be off while making connections.
7.
Turn on the power supply.
8.
Turn on the Power Pak power switch.
The power to the robot is now controlled by the Power Pak. When the power
switch is turned off, there is a 2 second delay before power is removed from the