MagnaTran 7.1 User’s Manual
Command Reference
MN-003-1600-00
Set Communication
Brooks Automation
Revision 2.2
8-121
Set Communication
Purpose
This command is used to set the serial communications and command execution
modes.
Format
SET COMM [ALL] [M/B mode] [FLOW flow] [LF linefeed] [ECHO echo] [CHECKSUM
checksum] [ERRLVL level] [DREP data_rep]
Arguments
mode:
Specifies the serial I/O communications mode.
MON Monitor mode (: )
PKT
Packet mode (_RDY)
flow:
Specifies the command execution type.
SEQ
Sequential mode
BKG Background mode
BKG+ Background Plus mode
linefeed:
Specifies the linefeed state.
ON
Linefeed enabled
OFF
Linefeed disabled
ECHO:
Specifies the ECHO state.
ON
Echo enabled
OFF
Echo disabled
checksum:
Specifies the checksum option state.
ON
Checksum enabled
OFF
Checksum disabled
data_rep:
Specifies the data reporting flag in VT5 compatibility format only. See
Appendix D: Robot Compatibility on page 11-5
AUT Automatic mode