Maintenance and Repair
MagnaTran 7.1 User’s Manual
I/O Board Replacement
MN-003-1600-00
Brooks Automation
9-48
Revision 2.2
I/O Board Replacement
NOTE:
It is not necessary to remove the robot to perform this repair procedure.
Required Tools
Performing the I/O board replacement procedure requires the following tools:
•
Medium flat head screwdriver
•
M3 hex wrench
Removal Procedure
WARNING
When equipment is off and power is secured per facilities lockout/
tagout procedure, the unit is classified as a Type 1 hazard category.
See
.
1.
Turn off power and disconnect the power and communications connections to
the robot.
DANGER
All power to the unit must be disconnected per the facilities’ lockout/
tagout procedure before servicing to prevent the risk of electrical
shock.
2.
Remove the protective covers as shown in
.
CAUTION
Observe proper ESD precautions when handling any electronic
device.
3.
Loosen the thumbscrews (2 places) that mount the I/O board and panel cover
assembly to the Z Mounting Plate. See