5 Operating the pump controller
86
bplogic intelligent pump controller
18/02/2021
Level 1
Level 2
Level 3
Description
WLAN Server
Sets up a WLAN connection
NTP server
Defines whether the date and time
are based on an NTP server or set
manually
Field bus
General
Field bus
selection
Displays the type of field bus used
BOOL
mapping
PLC
BPL
Defines the parameters for which
values are sent from the machine
controller to the pump controller.
UDINT
mapping
PLC
BPL
REAL
mapping
PLC
BPL
BOOL
mapping
BPL
PLC
Defines the parameters for which
values are sent from the pump
controller to the machine control-
ler.
Field bus
General
UDINT
mapping
BPL
PLC
REAL
mapping
BPL
PLC
Modbus RTU
Sets the Modbus RTU