5 Operating the pump controller
18/02/2021
bplogic intelligent pump controller
235
Fig.159: Selecting the process size for the display in the application oscillo-
scope
1
Defines the number of grid lines by which the curve will be moved in the
application oscilloscope’s coordinate system. In this way, you can move a
curve that is covering another curve.
2
Defines the gaps in the application oscilloscope’s coordinate system. In
this way, you can set the size to which the line diagram for this channel is
scaled.
If you set the “Auto” value, the pump controller determines the scaling
value automatically.
3
Defines whether the configured channel is hidden in the application oscil-
loscope.
4
Fills the channel with this parameter or the process size.
4.
Set the
Offset
for the required parameters or the required process size
5.
Set the
Units per separation
for the required parameters or the required proc-
ess size (Fig.159/2).
6.
Define whether the configured channel is hidden or shown in the application
oscilloscope (Fig.159/3).
7.
Tap the tick at the end of the row for the required parameter or the required
process size in order to fill the channel with this parameter or this process size
(Fig.159/4).
Your selection is saved, and the application oscilloscope is displayed.