![Agilent Technologies Infiniium 90000 Q-Series Programmer'S Manual Download Page 289](http://html1.mh-extra.com/html/agilent-technologies/infiniium-90000-q-series/infiniium-90000-q-series_programmers-manual_2868674289.webp)
Disk Commands
15
Agilent Infiniium 90000 Series Oscilloscopes Programmer's Reference
289
:DISK:SAVE:WAVeform
Command
:DISK:SAVE:WAVeform <source>,"<file_name>" [,<format>[,<header>]]
The :DISK:SAVE:WAVeform command saves a waveform to a disk. If the
source is ALL, all of the currently displayed waveforms are saved to the
file. If you use a file extension as shown below in the <format> variable,
then the type of file saved defaults to the extension type. If no format is
specified and no extension is used, the file is saved in the INTernal
format.
<source>
{ALL | CHANnel<N> | CLOCk | FUNCtion<F> | HISTogram | MTRend |
MSPectrum | EQUalized | WMEMory<N>}
MTRend and MSPectrum sources are only available if the oscilloscope has
the EZJIT option installed and the feature is enabled.
The CLOCk source is only available if the oscilloscope has the High Speed
Serial option installed and the feature is enabled.
The EQUalized source is only available if the oscilloscope has the High
Speed Serial option and the Serial Data Equalization option installed and
the features are enabled. This command uses the Feed- Forward Equalized
(FFE) signal as the source.
<N>
An integer, 1- 4.
<F>
An integer, 1- 16.
<file_name>
A quoted ASCII string with a maximum of 254 characters including the
entire path name, if used. The filename assumes the present working
directory if a path does not precede the file name. The default path is C:\
Document and Settings\All Users\Shared Documents\Infiniium\Data.
<format>
{BIN | CSV | INTernal | TSV | TXT | H5 | H5INt}
The following file name extensions are used for the different formats:
•
BIN = file_name.bin
•
CSV (comma separated values) = file_name.csv
•
INTernal = file_name.wfm
•
TSV (tab separated values) = file_name.tsv
•
TXT = file_name.txt
•
H5, H5INt (HDF5) = file_name.h5
N O T E
See the
":WAVeform:VIEW"
on page 977 command to determine how much data is saved.
Summary of Contents for Infiniium 90000 Q-Series
Page 1: ...s1 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference...
Page 50: ...50 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 2 Setting Up...
Page 274: ...274 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 14 Digital Commands...
Page 292: ...292 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 15 Disk Commands...
Page 318: ...318 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 16 Display Commands...
Page 364: ...364 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 17 Function Commands...
Page 382: ...382 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 19 Histogram Commands...
Page 412: ...412 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 21 Limit Test Commands...
Page 416: ...416 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 22 Lister Commands...
Page 696: ...696 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 25 Measure Commands...
Page 702: ...702 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 26 Pod Commands...
Page 760: ...760 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 29 Self Test Commands...
Page 818: ...818 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 31 System Commands...
Page 830: ...830 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 32 Time Base Commands...
Page 930: ...930 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 33 Trigger Commands...
Page 1018: ...1018 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 37 Error Messages...
Page 1150: ...1150 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference 38 Sample Programs...
Page 1186: ...1186 Agilent Infiniium 90000 Series Oscilloscopes Programmer s Reference Index...