G 01065 - Edition 06 - December 06
1/2
C 10
Operating mode
In local mode, the cover plugs delivered with the machine must be plugged
on J1 and J14 connectors.
In this case of operation, the pump is running as a stand-alone part of
the equipment on which it has been installed. The pump is controlled
by a hand-held remote control, connected in front or at the rear of the
frame, or by both simultaneously connected, one in front, the other at
the rear of the frame.
A second hand-held remote controlcan also be connected in series
with the first one.
Switch configuration
according to the hand-held
remote control layout
Different
control modes
Local mode
According to the monitoring configuration and wiring, the pump can
be:
locally controlled by the hand-held remote control,
remote controlled by serial link,
remote controlled using dry contacts via J 14 connector.
Two switches have to be configurated: the first at the back of hand-
held remote control and the second, S1, located on electrical interface
(see
A 20
).
Use of single hand-held remote control:
1
S1
J4
2
ON
1 2 3 4
ON
Connected at the rear
1
S1
2
ON
1 2 3 4
ON
Connected in front
Use of two hand-held remote control:
1
S1
2
ON
1 2 3 4
ON
2
1
3 4
ON
1
S1
J4
2
ON
1 2 3 4
ON
1 2 3 4
ON
Connected on both sides
Connected in series
For safety reasons, the pump can be controlled only by one hand-held
remote control at the same time.
adixen Vacuum Products - Operating instructions - ADP/ADS Series Two