Electrical connection
G 01055 - Edition 07 - Januar
y 10
Electrical hard wired
connection (continued)
Connect the mains cable to the
I1
main disconnect switch using a
cable with following specifications:
– AWG-12 (2.5 mm
2
) for ADP 122, or
– AWG-10 (4 mm
2
) for ADS 602/1202/ADS 1802.
(cable customer supply)
Connect the ground to the separate terminal bar.
Motor rotation is defined by main power connection.
Uncorrect wiring may cause backwards pump rotating.
Check rotation sense at first start up (see
B 51
).
Check that the cable is correctly protected against ground defects and that
earth wire is longer than the three conducting wires.