G 01052 - Edition 08 - Januar
y 1
0
1/3
B 25
Filling the machine oil housings
The pumps are delivered without an oil charge: the oil is delivered in
separate containers. In the same way, it is recommended to drain the pump
before returning the equipment.
For machines which use lubricants, it is recommended to request for the
safety data sheets from the manufacturer.
Mineral and synthetic oils cannot be used together. Contact the
manufacturer or your service agent before making any changes.
A113 medical safety data sheet is available upon request.
Oil quantities
Oil filling:
Housing : Dry pump
Roots
housing
gears side
Roots
housing
motor
side
Oil
capacity
Nber
of can
0.4 l
ADP 122
0.35
L
0.35
L
x 1
ADS 602
0.35
L
0.45
L
0.25
L
1.05
L
x 3
ADS 1202
0.35
L
1.00
L
0.55
L
1.90
L
x 5
ADS 1802*
0.15
L
1.00
L
0.55
L
1.65
L
x 4
* A300 dry pump of ADS 1802 pump is delivered filling with oil.
The pump is tested using synthetic fluid A113.
We recommend the exclusive use of this fluid.