2/2
C 20
M4 monitoring system parameters
G 01073 - Edition 08 - Januar
y 10
Unit
Thresholds
Initial configuration
Mini.
Maxi.
Alert
Alarm
Mass-flowmeter
slm
0
60 / 120
15
–
mn
0
60
0
disabled
ADP temperature sensor
°C
70
130
140
(ADS 1802)
85
120
Motor power sensor
W
500
5000
2500
4000
E. analogic sensor
mV
0
9950
4000
8000
LI1 logic sensor
mn
0
60
disabled
disabled
LI2 logic sensor
mn
0
60
disabled
disabled
LI3 logic sensor
mn
0
60
disabled
disabled
Auxiliary temperature
°C
0
170
< 20
> 140
disabled
Auxiliary temperature
(Roots temperature on
ADS 602 P and ADS 602 H)
°C
0
170
< 20
> 140
–
Auxiliary temperature
(Temperature control on
ADS 1802 H)
°C
70
100
85
120
Summary table
of monitoring
parameters
Max. and min.
thresholds
Sensor location
At the pump start-up, the monitoring operation will depend on the
programing done at the factory. However, the monitoring system can be
customized at any time according to the running process, by programing
the parameters of the various menus listed in
C 42
with the pump
stopped.
See sheet
D 10
.
adixen Vacuum Products - Operating instructions - ADP/ADS Series Two