2/4
C 43
Use of the M4 monitoring system for
pumping operation
G 01069 - Edition 07 - July 12
Start up the pump by pressing
START
.
The following operations will perform automatically:
inlet valve opens (if preselected),
ADP pump starts up,
data capture and sensor processing,
purge gas valve opens (P version and H version) if option
CMD.PURGE
disabled
Roots pump starts up (if selected).
At the same time the operating
parameters are displayed.
Gain access to other operating
parameters* using
+
or
–
keys.
(*) Only installed and configurated options parameters are displayed.
Note: for thermal regulated pumps, “
THERM ADP
“ water valve opens
when the temperature reaches the ADP temperature set value. It closes
when the temperature decreases -2°C below the ADP temperature set
value.
52H LOC N2
ROOTS
ADP.POWER 1410
W
PRESSURE 940
MBAR
ADP TEMP.
58°C
Pump start-up
During operation, the user is warned of an operating incident by:
one or several faults are displayed on the screen, alternating
with monitoring parameters. When these faults are activated, the
monitoring system triggers the warning phase followed by the
hazard phase. The period of time for these phases can be set.
indicator lights on the front panel and buzzer sounded, if option
selected.
indicator lights on display panel.
the fault contacts on the remote connector J14 at the rear of the
monitoring unit are closed.
pumping is stopped when an hazard threshold or a time is
reached.
A list of incidents is given in the
chapter D
.
Operation monitoring
The pumps are equipped with an exhaust pressure monitoring sensor.
It is the responsibility of the user to prevent the risks related to excess
overpressure.
The user and /or OEM are ultimately responsible for operating the equipment
in a safe manner. The manufacturer has no control over the types of gases
exposed to this pump. This is the user and/or the OEM’s responsibility to follow
the necessary safety requirements.
Frequently process gases are toxic, flammable, corrosive, explosive and/or
otherwise reactive.
Toxic gases can cause serious injury or death. Operators and users must
take the appropriate safety recommendations to prevent injury. Consult the
responsible department for instructions and safety information.
adixen Vacuum Products - Operating instructions - ADP/ADS Series Two