Name
Values (Range)
Unit
Step
Default
Description
OverTrigOp31
Off
On
-
-
Off
Use over level trigger for analog channel
31 (on) or not (off)
OverTrigLe31
0 - 5000
%
1
200
Over trigger level for analog channel 31 in
% of signal
NomValue32
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 32
UnderTrigOp32
Off
On
-
-
Off
Use under level trigger for analog channel
32 (on) or not (off)
UnderTrigLe32
0 - 200
%
1
50
Under trigger level for analog channel 32
in % of signal
OverTrigOp32
Off
On
-
-
Off
Use over level trigger for analog channel
32 (on) or not (off)
OverTrigLe32
0 - 5000
%
1
200
Over trigger level for analog channel 32 in
% of signal
NomValue33
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 33
UnderTrigOp33
Off
On
-
-
Off
Use under level trigger for analog channel
33 (on) or not (off)
UnderTrigLe33
0 - 200
%
1
50
Under trigger level for analog channel 33
in % of signal
OverTrigOp33
Off
On
-
-
Off
Use over level trigger for analog channel
33 (on) or not (off)
OverTrigLe33
0 - 5000
%
1
200
Overtrigger level for analog channel 33 in
% of signal
NomValue34
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 34
UnderTrigOp34
Off
On
-
-
Off
Use under level trigger for analog channel
34 (on) or not (off)
UnderTrigLe34
0 - 200
%
1
50
Under trigger level for analog channel 34
in % of signal
OverTrigOp34
Off
On
-
-
Off
Use over level trigger for analog channel
34 (on) or not (off)
OverTrigLe34
0 - 5000
%
1
200
Over trigger level for analog channel 34 in
% of signal
NomValue35
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 35
UnderTrigOp35
Off
On
-
-
Off
Use under level trigger for analog channel
35 (on) or not (off)
UnderTrigLe35
0 - 200
%
1
50
Under trigger level for analog channel 35
in % of signal
OverTrigOp35
Off
On
-
-
Off
Use over level trigger for analog channel
35 (on) or not (off)
OverTrigLe35
0 - 5000
%
1
200
Over trigger level for analog channel 35 in
% of signal
NomValue36
0.0 - 999999.9
-
0.1
0.0
Nominal value for analog channel 36
UnderTrigOp36
Off
On
-
-
Off
Use under level trigger for analog channel
36 (on) or not (off)
UnderTrigLe36
0 - 200
%
1
50
Under trigger level for analog channel 36
in % of signal
OverTrigOp36
Off
On
-
-
Off
Use over level trigger for analog channel
36 (on) or not (off)
Table continues on next page
Section 14
1MRK 504 135-UEN A
Monitoring
458
Technical manual
Summary of Contents for ret650
Page 1: ...Relion 650 series Transformer protection RET650 Technical manual ...
Page 2: ......
Page 40: ...34 ...
Page 62: ...56 ...
Page 84: ...78 ...
Page 208: ...202 ...
Page 376: ...370 ...
Page 414: ...408 ...
Page 530: ...524 ...
Page 562: ...556 ...
Page 620: ...614 ...
Page 668: ...662 ...
Page 669: ...663 ...