188
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
10.33 DI9Invert (invert digital input 9)
Inversion selection for digital input 9:
0 = Direct
only available with digital extension board
1 = Inverted only available with digital extension board
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.34 DI10Invert (invert digital input 10)
Inversion selection for digital input 10:
0 = Direct
only available with digital extension board
1 = Inverted only available with digital extension board
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.35 DI11Invert (invert digital input 11)
Inversion selection for digital input 11:
0 = Direct
only available with digital extension board
1 = Inverted only available with digital extension board
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
Group 11: Speed reference inputs
11.01 Unused
11.02 Ref1Mux (speed reference 1 selector/multiplexer)
Speed reference 1 selector:
0 = Open
switch for speed ref. 1 is fixed open
1 = Close
switch for speed ref 1 is fixed closed, default
2 = DI1
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
3 = DI2
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
4 = DI3
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
5 = DI4
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
6 = DI5
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
7 = DI6
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
8 = DI7
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
9 = DI8
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0
10 = DI9
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; only
available with digital extension board
11= DI10
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; only
available with digital extension board
12 = DI11
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; only
available with digital extension board
13 = MCW Bit11
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 11
14 = MCW Bit12
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 12
15 = MCW Bit13
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 13
16 = MCW Bit14
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 14
17 = MCW Bit15
1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0;
MainCtrlWord (7.01) bit 15
Int. Scaling: 1 == 1
Type: C
Volatile:
N
O
pen
M
C
W
B
it
15
Cl
o
s
e
-
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...