Group 99: Start-up data
99.01 Language (language)
Select language:
0 = English default
1 = reserved
2 = Deutsch
3 = Italiano
4 = Español
5 = reserved
6 = reserved
7 = Français
Int. Scaling: 1 == 1
Type: C
Volatile:
N
E
ngl
is
h
E
ngl
is
h
E
ngl
is
h
-
99.02 M1NomVolt (nominal DC voltage)
Nominal armature voltage (DC) from the motor rating plate.
Int. Scaling: 1 == 1 V
Type: I
Volatile:
N
5
700
350
V
99.03 M1NomCur (nominal DC current)
Nominal armature current (DC) from the motor rating plate.
Int. Scaling: 1 == 1 A
Type: I
Volatile:
N
0
1000
0
A
99.04 M1BaseSpeed (base speed)
Base speed from the rating plate, usually the field weak point. M1BaseSpeed (99.04) is must be set in the
range of:
−
0.2 to 1.6 times of SpeedScaleAct (2.29).
If the scaling is out of range A124 SpeedScale [AlarmWord2 (9.07) bit 7] is generated.
Int. Scaling: 10 == 1 rpm Type: I
Volatile:
N
10
6500
1500
rp
m
99.05 Unused
99.06 ServiceMode (service mode)
ServiceMode (99.06) contains several test- and auto tuning procedures.
The drive mode is automatically set to NormalMode after an autotuning procedure or after the thyristor
diagnosis is finished or failed. In case errors occur during the selected procedure A121 AutotuneFail
[AlarmWord2 (9.07) bit 4] is generated. The reason of the error can be seen in Diagnosis (9.11).
SetTypeCode is automatically set to NormalMode after the next power up.
0 = NormalMode
normal operating mode depending on OperModeSel (43.01), default
1 = ArmCurAuto
autotuning armature current controller
2 = FieldCurAuto
autotuning field current controller
3 = EMF FluxAuto
autotuning EMF controller and flux linearization
4 = SpdCtrlAuto
autotuning speed controller
5 = SpdFbAssist
test speed feedback, see M1SpeedFbSel (50.03), M1EncPulseNo (50.04) and
M1TachoVolt1000 (50.13)
6 = TachFineTune
tacho fine tuning, see M1TachoAdjust (50.12)
7 = ThyDiagnosis
thyristor diagnosis, the result is shown in Diagnosis (9.11)
8 = FindDiscCur
find discontinuous current limit
9 = SetTypeCode
set type code, releases following parameters:
TypeCode (97.01)
10 = LD FB Config
reserved for future use (load fieldbus configuration file)
Note:
The reference chain is blocked while ServiceMode (99.06)
≠
NormalMode.
Int. Scaling: 1 == 1
Type: C
Volatile:
Y
N
or
m
al
M
od
e
F
indD
is
c
C
ur
N
or
m
al
M
od
e
-
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...