63.01 TensRefIn (tension reference, tension reference input)
Source (signal/parameter) for the tension reference input of the tension reference. The format is xxyy, with:
xx = group and yy = index.
As default, nothing is connected to the input.
Examples:
−
Setting of 516 uses AI2 Val (5.16) as tension reference.
−
Setting of 1901 uses Data1 (19.01) and could be used for reference via fieldbus
−
Setting of 8501 uses Constant1 (85.01) and could be used as constant reference
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
0
-
63.02 TaperDiaActIn (tension reference, actual diameter input)
Source (signal/parameter) for the actual diameter input of the tension reference used for taper tension
calculation. The format is xxyy, with: xx = group and yy = index.
Default setting of 6208 equals DiameterAct (62.08).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
6208
-
63.03 TensValueIn (tension reference, standstill tension value input)
Source (signal/parameter) for the standstill tension reference input of the tension reference. The format is
xxyy, with: xx = group and yy = index. The standstill tension is usually set when the line speed is zero.
As default, nothing is connected to the input.
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
0
-
63.04 TensSetCmd (tension reference, set tension value command)
Source to release the standstill tension reference - see TensValueIn (63.03) - or release the tension reference
- see TensRefIn (63.01):
0 = TensionRef
constant 0; release tension reference
1 = Auto
depending on winder logic and winder macro, see WinderMacro (61.01), default
2 = StanstilTens
constant 1; release standstill tension reference
3 = WindCtrlWord according to WindCtrlWord (61.16) bit 10
4 = DI1
1 = release standstill tension reference; 0 = release tension reference
5 - 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1
Type: C
Volatile:
N
T
ens
ionR
ef
1905B
it
3
Au
to
-
63.05 TaperDia (tension reference, taper diameter)
Diameter of the coil, in percent of the maximum diameter, from where the tension reduction for tapering
begins.
Int. Scaling: 100 == 1 % Type: I
Volatile:
N
0
100
1
%
63.06 TaperTens (tension reference, taper tension)
Diameter dependent tension reduction, in percent of the maximum tension, for tapering. The value of
TaperTens (63.06) is reached at the maximum diameter. Setting TaperTens (63.06) = 0 disables the function.
To reduce the tension linear use positive values. To reduce the tension hyperbolic use negative values.
Int. Scaling: 100 == 1 % Type: I
Volatile:
N
-10
0
100
0
%
63.07 TensRefMin (tension reference, minimum tension reference)
Minimum tension reference in percent of the maximum tension.
Int. Scaling: 100 == 1 % Type: I
Volatile:
N
0
100
1
%
63.08 TensRampTime (tension reference, ramp time)
Ramp time of for the tension reference from zero percent tension to 100 % tension.
Int. Scaling: 1 == 1
Type: C
Volatile:
N
0
300
2
s
TaperDia (63.05)
Max. diameter (= 100 %)
TaperTens (63.06)
63.06>0
63.06<0
TaperDia (63.05)
Max. diameter (= 100 %)
TaperTens (63.06)
TaperDia (63.05)
Max. diameter (= 100 %)
TaperTens (63.06)
63.06>0
63.06<0
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...