1.08 MotTorq (motor torque)
Motor torque in percent of MotNomTorque (4.23):
−
Filtered by means of a 6th order FIR filter (sliding average filter), filter time is 1 mains voltage period.
Notes:
−
The cycle time is 20 ms
−
The value is calculated the following way:
NotUsed
e
UsedFexTyp
M
or
BaseSpeed
M
n
for
FluxMax
fFldWeak
Flux
or
BaseSpeed
M
n
for
MotSpeed
BaseSpeed
M
FluxMax
fFldWeak
Flux
with
MotCur
fFldWeak
Flux
MotTorq
=
≤
=
=
>
=
=
)
12
.
99
(
1
)
04
.
99
(
1
%;
100
)
24
.
3
(
Re
)
04
.
99
(
1
;
)
04
.
1
(
)
04
.
99
(
1
*
)
24
.
3
(
Re
100
)
06
.
1
(
*
)
24
.
3
(
Re
)
08
.
1
(
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
1.09 Unused
1.10 CurRippleFilt (filtered current ripple)
Relative filtered current ripple monitor output in percent of M1NomCur (99.03) filtered with 200 ms.
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
1.11 MainsVoltActRel (relative actual mains voltage)
Relative actual mains voltage in percent of NomMainsVolt (99.10).
Int. Scaling: 100 == 1 % Type: I
Volatile:
Y
-
-
-
%
1.12 MainsVoltAct (actual mains voltage)
Actual mains voltage filtered with 10 ms.
Int. Scaling: 1 == 1 V
Type: I
Volatile:
Y
-
-
-
V
1.13 ArmVoltActRel (relative actual armature voltage)
Relative actual armature voltage in percent of M1NomVolt (99.02).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
1.14 ArmVoltAct (actual armature voltage)
Actual armature voltage filtered with 10 ms.
Int. Scaling: 1 == 1 V
Type: SI
Volatile:
Y
-
-
-
V
1.15 ConvCurActRel (relative actual converter current [DC])
Relative actual converter current in percent of ConvNomCur (4.05).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
1.16 ConvCurAct (actual converter current [DC])
Actual converter current filtered with 10 ms.
Int. Scaling: 1 == 1 A
Type: SI
Volatile:
Y
-
-
-
A
1.17 EMF VoltActRel (relative actual EMF)
Relative actual EMF in percent of M1NomVolt (99.02):
−
EMF VoltActRel (1.17).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
1.18 - 1.19 Unused
1.20 Mot1TempCalc (calculated temperature)
Calculated temperature from motor thermal model in percent - see M1AlarmLimLoad (31.03) and
M1FaultLimLoad (31.04). Used for motor overload protection.
−
M1AlarmLimLoad (31.03)
−
M1FaultLimLoad (31.04)
Int. Scaling: 100 == 1 % Type: I
Volatile:
Y
-
-
-
%
1.21 Unused
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...