In this manner, it is possible to insert up to 16 function blocks from the list to the desktop. The button Change
Block xx changes the selected block. The button Insert Before Block xx inserts the new block before the
selected block. Button Insert After Block xx inserts the new block after the selected block:
Connect function blocks
It is possible to connect function blocks to other blocks or to firmware parameters. To connect use Ctrl + left
mouse button on the red cross at the input. This opens the pop-up window Set Pointer Parameter. This
window provides several connection possibilities:
−
Connect a Parameter from the list and set the bit in case of connecting a packed boolean value:
−
Connect a Constant value to the input: