162
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
3.27 FluxRefEMF (flux reference after EMF controller)
Relative EMF flux reference in percent of nominal flux after EMF controller.
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
3.28 FluxRefSum (sum of flux reference)
FluxRefSum (3.28) = FluxRefEMF (3.27) + FluxRefFldWeak (3.24) in percent of nominal flux.
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
3.29 Unused
3.30 FldCurRefM1 (field current reference)
Relative field current reference in percent of M1NomFldCur (99.11).
Int. Scaling: 100 == 1 % Type: SI
Volatile:
Y
-
-
-
%
Group 4: Information
4.01 FirmwareVer (firmware version)
Name of the loaded firmware version. The format is:
yyy or -yyy
with: yyy = consecutively numbered version and -yyy = single-phase firmware for demo units.
Int. Scaling: -
Type: C
Volatile:
Y
-
-
-
-
4.02 FirmwareType (firmware type)
Type of the loaded firmware version. The format is:
55 = Standard firmware
Int. Scaling: -
Type: C
Volatile:
Y
-
-
-
-
4.03 Unused
4.04 ConvNomVolt (converter nominal AC voltage measurement circuit)
Adjustment of AC voltage measuring channels (SDCS-PIN-F). Read from TypeCode (97.01).
Int. Scaling: 1 == 1 V
Type: I
Volatile:
Y
-
-
-
V
4.05 ConvNomCur (converter nominal DC current measurement circuit)
Adjustment of DC current measuring channels (SDCS-PIN-F). Read from TypeCode (97.01).
Int. Scaling: 1 == 1 A
Type: I
Volatile:
Y
-
-
-
A
4.06 Mot1FexType (type of field exciter)
Field exciter type. Read from M1UsedFexType (99.12):
0 = NotUsed
no or third party field exciter connected
1 = OnBoard
integrated 1-Q field exciter, default
Int. Scaling: 1 == 1
Type: C
Volatile:
Y
-
-
-
-
4.07 - 4.13 Unused
4.14 ConvType (converter type)
Recognized converter type. Read from TypeCode (97.01):
0 = reserved
1 = F1
F1 converter
2 = F2
F2 converter
3 = F3
F3 converter
4 = F4
F4 converter
Int. Scaling: 1 == 1
Type: C
Volatile:
Y
-
-
-
-
4.15 QuadrantType (quadrant type of converter; 1 or 2 bridges)
Recognized converter quadrant type. Read from TypeCode (97.01) or set with S BlockBrdg2 (97.07):
−
Read from TypeCode (97.01) if S BlockBrdg2 (97.07) = 0
−
Read from S BlockBrdg2 (97.07) if S BlockBrdg2 (97.07)
≠
0
0 = BlockBridge2
bridge 2 blocked (== 2-Q operation)
1 = RelBridge2
bridge 2 released (== 4-Q operation), default
Int. Scaling: 1 == 1
Type: C
Volatile:
Y
-
-
-
-
4.16 ConvOvrCur (converter overcurrent [DC] level)
Converter current tripping level. This signal is set during initialization of the drive, new values are shown after
the next power-up.
Int. Scaling: 1 == 1 A
Type: I
Volatile:
Y
-
-
-
A
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...