260
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
90.10 DsetXplus6Val1 (data set X+6 value 1)
Data set 7 value 1 (interval: 3 ms).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
0
-
Group 92: Transmit data sets addresses
Addresses for the transmit data send from the drive to the overriding control.
The format is xxyy, with: xx = group and yy = index.
92.01 DsetXplus1Val1 (data set X+1 value 1)
Data set 2 value 1 (interval: 3 ms)
Default setting of 801 equals MainStatWord (8.01).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
801
-
92.02 DsetXplus1Val2 (data set X+1 value 2)
Data set 2 value 2 (interval: 3 ms).
Default setting of 104 equals MotSpeed (1.04).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
104
-
92.03 DsetXplus1Val3 (data set X+1 value 3)
Data set 2 value 3 (interval: 3 ms).
Default setting of 209 equals TorqRef2 (2.09).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
209
-
92.04 DsetXplus3Val1 (data set X+3 value 1)
Data set 4 value 1 (interval: 3 ms).
Default setting of 802 equals AuxStatWord (8.02).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
802
-
92.05 DsetXplus3Val2 (data set X+3 value 2)
Data set 4 value 2 (interval: 3 ms).
Default setting of 101 equals MotSpeedFilt (1.01).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
1
01
-
92.06 DsetXplus3Val3 (data set X+3 value 3)
Data set 4 value 3 (interval: 3 ms).
Default setting of 108 equals MotTorq (1.08).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
108
-
92.07 DsetXplus5Val1 (data set X+5 value 1)
Data set 6 value 1 (interval: 3 ms).
Default setting of 901 equals FaultWord1 (9.01).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
901
-
92.08 DsetXplus5Val2 (data set X+5 value 2)
Data set 6 value 2 (interval: 3 ms). Data.
Default setting of 902 equals FaultWord2 (9.02).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
902
-
92.09 DsetXplus5Val3 (data set X+5 value 3)
Data set 6 value 3 (interval: 3 ms).
Default setting of 903 equals FaultWord3 (9.03).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
903
-
e.g. DWL
Group
Data words
Overriding control
92
Address
assignment
SDCS-CON-F
Serial communication via
slot 1 of SDCS-CON-F
1
...
10
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...