142
Winder
3ADW000379R0501 DCS550 Manual e e
Indirect tension control
Indirect tension control is an open loop control, since the actual tension is not measured. The tension is controlled via
diameter and pre-set charts for inertia and friction. The speed controller stays active, but is saturated. This structure
provides a very robust control behavior because no physical tension measurement is required. Following parameters are
set when using WinderMacro (61.01) = IndirectTens:
Parameter name
IndirectTens
Factory (default)
Ref1Sel (11.03)
AI1
SpeedRef2301
TorqMaxSPC (20.07)
120 %
325 %
TorqMinSPC (20.08)
-120 %
-325 %
IndepTorqMaxSPC (20.24)
325 %
325 %
IndepTorqMinSPC (20.25)
-10 %
-325 %
SpeedCorr (23.04)
0 rpm
0 rpm
SpeedRefScale (23.16)
100 %
100 %
TorqSel (26.01)
Speed
Speed
TorqMuxMode (26.04)
TorqSel2601
TorqSel2601
LoadComp (26.02)
0 %
0 %
KpPID (40.01)
5
5
TiPID (40.02)
2500
2500
PID Act1 (40.06)
0
0
PID Ref1 (40.13)
0
0
PID OutMin (40.16)
-100 %
-100 %
PID OutMax (40.17)
100 %
100 %
PID OutDest (40.18)
0
0
PID ReleaseCmd (40.23)
Auto
Auto
WriteToSpdChain (61.02)
Auto
Auto
WindUnwindCmd (61.04)
WindCtrlWord
WindCtrlWord
TopBottomCmd (61.05)
WindCtrlWord
WindCtrlWord
WinderOnCmd (61.06)
DI1
Auto
TensionOnCmd (61.07)
Auto
Auto
WindSpdOffset (61.14)
150 rpm, connected to SpeedCorr (23.04)
0
DiaLineSpdIn (62.01)
202 = SpeedRef2 (2.02)
202 = SpeedRef2 (2.02)
DiaMotorSpdIn (62.02)
104 = MotSpeed (1.04)
104 = MotSpeed (1.04)
DiameterSetCmd (62.04)
DI2
NotUsed
AdaptKpDiaActIn (62.10)
6208 = DiameterAct (62.08)
6208 = DiameterAct (62.08)
AdaptKpOutDest (62.13)
2403 = KpS (24.03)
0
AccActIn (62.17)
216 = dv_dt (2.16)
216 = dv_dt (2.16)
InerDiaActIn (62.23)
6208 = DiameterAct (62.08)
6208 = DiameterAct (62.08)
InerAccActIn (62.24)
6221 = AccActAdjust (62.21)
6221 = AccActAdjust (62.21)
InerReleaseCmd (62.28)
Auto
Auto
TensRefIn (63.01)
516 = AI2 ValScaled (5.16)
0
TaperDiaActIn (63.02)
6208 = DiameterAct (62.08)
6208 = DiameterAct (62.08)
TensValueIn (63.03)
0
0
TensSetCmd (63.04)
Auto
Auto
TensRampHoldCmd (63.09)
RelTensRamp
RelTensRamp
TensPulseCmd (63.13)
Auto
Auto
TTT Ref1In (63.18)
0
0
TTT Ref2In (63.19)
6315 = TensionRef (63.15)
6315 = TensionRef (63.15)
TTT Ref3In (63.20)
0
0
TTT DiaActIn (63.22)
6208 = DiameterAct (62.08)
6208 = DiameterAct (62.08)
FrictMotorSpdIn (63.31)
104 = MotSpeed (1.04)
104 = MotSpeed (1.04)
FrictReleaseCmd (63.32)
Auto
Auto
Add1OutDest (64.01)
2024 =IndepTorqMaxSPC (20.24)
0
Add1In1 (64.02)
6324 = TensToTorq (63.24)
6324 = TensToTorq (63.24)
Add1In2 (64.03)
0
0
Add1ReleaseCmd (64.04)
Auto
Auto
Add2OutDest (64.08)
2602 = LoadComp (26.02)
0
Add2In1 (64.09)
6230 = InertiaComp (62.30)
6230 = InertiaComp (62.30)
Add2In2 (64.10)
6334 = FrictionComp (63.34)
6334 = FrictionComp (63.34)
Add2ReleaseCmd (64.11)
Auto
Auto
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...