241
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
62.04 DiameterSetCmd (diameter calculation, set initial diameter value command)
Source for command to set the initial diameter of the coil:
0 = NotUsed
constant 0; no action, default
1 = reserved
2 = Set
constant 1; read DiameterValue (62.03) and connect it to DiameterAct (62.08)
3 = WindCtrlWord according to WindCtrlWord (61.16) bit 7
4 = DI1
1= read DiameterValue (62.03) and connect it to DiameterAct (62.08); 0 = calculate
diameter and connect it to DiameterAct (62.08)
5 - 23 see WriteToSpdChain (61.02)
Int. Scaling: 1 == 1
Type: C
Volatile:
N
No
tUs
e
d
1905B
it
3
No
tUs
e
d
-
62.05 DiameterMin (diameter calculation, minimum diameter)
Minimum diameter of the coil in percent of the maximum diameter.
Int. Scaling: 100 == 1 % Type: I
Volatile:
N
1
100
10
%
62.06 DiaRampTime (diameter calculation, ramp time)
Filter time for the diameter calculation to adapt the initial diameter to the actual diameter.
−
The slope is dependent on a PT1-filter using positive times.
−
The slope of the ramp is diameter dependent using negative ramp times.
Int. Scaling: 100 == 1 s
Type: I
Volatile:
N
-300
300
10
s
62.07 DiaMotorSpdLev (diameter calculation, motor speed level)
As soon as the motor speed reaches the level set by DiaMotorSpdLev (62.07) the diameter calculation is
released.
Internally limited from:
rpm
to
rpm
)
29
.
2
(
0
Int. Scaling: (2.29)
Type: I
Volatile:
N
0
1000
20
rp
m
62.08 DiameterAct (diameter calculation, actual diameter output)
Output of the diameter calculation. Calculated actual diameter in percent of the maximum diameter. This value
is automatically written to SpeedRefScale (23.16) in case WinderMacro (61.01) = VelocityCtrl, IndirectTens,
DirectTens or DancerCtrl and WriteToSpdChain (61.02) is high.
Int. Scaling: 100 == 1 % Type: I
Volatile:
Y
-
-
-
%
62.09 Unused
Use the p-part adaption to adapt the speed controller p-part according to actual diameter of the coil. It is variable between
minimum diameter and maximum diameter. Use the smallest p-part with minimum diameter. With maximum diameter,
send the largest p-part to the speed controller.
Commissioning hint:
−
AdaptKpMin (62.11) has to be determined by manual tuning of the speed controller. Only the spool is on the winder
and set WinderMacro (61.01) = NotUsed.
−
AdaptKpMax (62.12) has to be determined by manual tuning of the speed controller. The largest coil (maximum
diameter and maximum width) has to be on the winder and set WinderMacro (61.01) = NotUsed.
62.10 AdaptKpDiaActIn (speed controller p-part adaption, actual diameter input)
Source (signal/parameter) for the actual diameter input of the speed controller adaption. The format is xxyy,
with: xx = group and yy = index.
Default setting of 6208 equals DiameterAct (62.08).
Int. Scaling: 1 == 1
Type: I
Volatile:
N
0
9999
6208
-
62.11 AdaptKpMin (speed controller p-part adaption, minimum p-part)
Proportional gain of the speed controller with minimum diameter (spool).
Int. Scaling: 100 == 1
Type: I
Volatile:
N
0
325
5
-
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...