187
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
m
in.
ma
x.
def
.
uni
t
10.22 DynBrakeAck (dynamic braking acknowledge)
The drive sets A105 DynBrakeAck [AlarmWord1 (9.06) bit 4] if a digital input for dynamic braking is selected
and the acknowledge (dynamic braking active) is still present when On [UsedMCW (7.04) bit 3] is set.
Selections see MainContAck (10.21).
A105 DynBrakeAck [AlarmWord1 (9.06) bit 4] should prevent the drive to be started while dynamic braking is
active.
Int. Scaling: 1 == 1
Type: C
Volatile:
N
No
tUs
e
d
DI
1
1
No
tUs
e
d
-
10.23 DC BreakAck (DC breaker acknowledge)
The drive sets A103 DC BreakAck [AlarmWord1 (9.06) bit 2] if a digital input for the DC-breaker is selected
and the acknowledge is missing. Selections see MainContAck (10.21).
The motor will coast if A103 DC BreakAck [AlarmWord1 (9.06) bit 2] is set.
Int. Scaling: 1 == 1
Type: C
Volatile:
N
No
tUs
e
d
DI
1
1
No
tUs
e
d
-
10.24 Unused
10.25 DI1Invert (invert digital input 1)
Inversion selection for digital input 1:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.26 DI2Invert (invert digital input 2)
Inversion selection for digital input 2:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.27 DI3Invert (invert digital input 3)
Inversion selection for digital input 3:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.28 DI4Invert (invert digital input 4)
Inversion selection for digital input 4:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.29 DI5Invert (invert digital input 5)
Inversion selection for digital input 5:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.30 DI6Invert (invert digital input 6)
Inversion selection for digital input 6:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.31 DI7Invert (invert digital input 7)
Inversion selection for digital input 7:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
10.32 DI8Invert (invert digital input 8)
Inversion selection for digital input 8:
0 = Direct
1 = Inverted
Int. Scaling: 1 == 1
Type: C
Volatile:
N
Di
re
c
t
Inv
er
ted
Di
re
c
t
-
Summary of Contents for DCS550 Series
Page 1: ... DCS550 Manual DCS550 Drives 20 A to 1000 A ...
Page 141: ...141 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 143: ...143 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 145: ...145 Winder 3ADW000379R0501 DCS550 Manual e e ...
Page 147: ...147 Winder 3ADW000379R0501 DCS550 Manual e e ...