16-43
IM 701210-06E
Ethernet Interface (Optional)
16
• Sending Commands (*Command IEEE 488.2)
Entering the Transmission Commands
Enter the commands in the transmission command entry area.
Maximum number of input characters: Up to 50,000 (50 KB).
Sending Commands
Click
Send
to send the commands in the transmission command entry area
collectively in the order displayed in the area.
Clearing the Entered Commands (Clear Command Area)
Click
Clear Command Area
to clear all the commands in the transmission command
entry area.
• Displaying the Responses from the DL750/DL750P (*Response)
The responses from the DL750/DL750P against the commands (queries) sent to the
DL750/DL750P using the control script function can be received and displayed.
Clearing the Responses (Clear Response Area)
Click
Clear Response Area
to clear all the responses received from the DL750/
DL750P that are displayed in the response display area.
• Sending Commands Periodically and Displaying Responses
The commands in the transmission command entry area can be sent periodically. If
commands (queries) that request responses from the DL750/DL750P are sent, the
responses from the DL750/DL750P are displayed in the response display area.
Setting the Transmission Interval
Select the command transmission interval from the following:
2 s, 5 s, 10 s, 30 s, and 60 s
Starting Periodic Transmission (Start)
Click
Start/Stop
. The indicator illuminates in yellow, and the command transmission
and response display start at the specified transmission interval.
Stopping Periodic Transmission (Stop)
Click
Start/Stop
while the periodic transmission is in progress. The indicator turns
OFF, and the command transmission and response reception/display stop. However,
if the last command before stopping the periodic transmission was a query command,
the response to that command is displayed in the response display area.
Note
•
If a wrong command is sent, the error message is not automatically displayed in the
Control Script window. The error code and message are displayed by entering the
“
:status:error?
” command in the transmission command entry area and sending the
command. You can also confirm the error on the screen image displayed using the data
capture function and also on the DL750/DL750P screen.
•
Binary data cannot be received or displayed.
•
The transmission timeout is 30 s. Transmission and reception exceeding 30 s results in a
timeout error. If all the commands specified in the transmission command entry area is
sent, and the responses to the commands are not received within 30 s, a timeout error
occurs.
16.7 Using the Web Server Function