YOKOGAWA ScopeCorder DL750 Скачать руководство пользователя страница 15

Part 2:xiv

IM 701210-06E

Contents

Chapter 6

Triggering

6.1

Setting the Trigger Mode .......................................................................................... 6-1

6.2

Setting the Trigger Position ...................................................................................... 6-3

6.3

Setting the Trigger Delay ......................................................................................... 6-5

6.4

Setting the Hold Off Time ......................................................................................... 6-6

6.5

Setting the Edge Trigger (SIMPLE) .......................................................................... 6-8

6.6

Setting the External Trigger (SIMPLE) ................................................................... 6-11

6.7

Generating Triggers on the Power Signal (SIMPLE) ............................................. 6-12

6.8

Setting the Timer Trigger (SIMPLE) ....................................................................... 6-13

6.9

Setting the Logic Trigger (SIMPLE) ....................................................................... 6-15

6.10

Setting the A -> B(N) Trigger (ENHANCED) .......................................................... 6-17

6.11

Setting the A Delay B Trigger (ENHANCED) ......................................................... 6-20

6.12

Setting the Edge on A Trigger (ENHANCED) ......................................................... 6-23

6.13

Setting the OR Trigger (ENHANCED) .................................................................... 6-27

6.14

Setting the B > Time, B < Time, or B TimeOut (Pulse Width) Trigger

(ENHANCED) ........................................................................................................ 6-30

6.15

Setting the Period Trigger (ENHANCED) ............................................................... 6-34

6.16

Setting the Window Trigger (ENHANCED) ............................................................ 6-37

6.17

Setting the Wave Window Trigger (ENHANCED) .................................................. 6-40

6.18

Setting the Action-on-Trigger ................................................................................. 6-45

6.19

Setting Manual Triggers ......................................................................................... 6-48

Chapter 7

Acquisition and Display

7.1

Starting/Stopping Waveform Acquisition .................................................................. 7-1

7.2

Setting the Record Length ....................................................................................... 7-3

7.3

Setting the Acquisition Mode .................................................................................... 7-5

7.4

Acquiring Data Using Box Average .......................................................................... 7-8

7.5

Acquiring Data Using the Sequential Store Function (Single (N) Mode) ............... 7-10

7.6

Using the Dual Capture Function ........................................................................... 7-11

7.7

Realtime Recording to the Internal Hard Disk (Optional) ....................................... 7-16

7.8

Setting the Action When Waveform Display Is Updated (Action-on-Stop) ............. 7-20

7.9

Using the Voice Memo Function ............................................................................ 7-23

7.10

Using the Acquisition Memory Backup Function .................................................... 7-29

Chapter 8

Display

8.1

Changing the Display Format .................................................................................. 8-1

8.2

Setting the Display Interpolation Method ................................................................. 8-3

8.3

Changing the Graticule ............................................................................................ 8-5

8.4

Accumulated Waveform Display .............................................................................. 8-6

8.5

Zooming the Waveform ............................................................................................ 8-8

8.6

Displaying X-Y Waveforms .................................................................................... 8-12

8.7

Using the Snapshot Function and Clear Trace Function ....................................... 8-15

8.8

Turning Translucent Mode ON/OFF ....................................................................... 8-16

8.9

Turning the Scale Value Display ON/OFF .............................................................. 8-17

8.10

Setting Waveform Labels ....................................................................................... 8-18

8.11

Turning the Extra Window ON/OFF ....................................................................... 8-19

8.12

Turning the Level Indicator and Numeric Value Display ON/OFF .......................... 8-21

8.13

Displaying Channel Information/Displaying Waveforms on a Full Screen

(Expanding the Waveform Area) ............................................................................ 8-22

Содержание ScopeCorder DL750

Страница 1: ...ScopeCorder IM 701210 06E 4th Edition Part 1 Part 2 ...

Страница 2: ...eproducing all or any part of the contents of this manual without the permission of Yokogawa Electric Corporation is strictly prohibited The TCP IP software of this product and the document concerning the TCP IP software have been developed created by YOKOGAWA based on the BSD Networking Software Release 1 that has been licensed from University of California Trademarks Microsoft Internet Explorer ...

Страница 3: ...veform Display and Information Display Chapter 9 Recording in Recorder Mode Realtime Recording DL750P Only Index Common to Part 1 and Part 2 User s Manual Part 2 IM701210 06E DL750 DL750P ScopeCoder User s Manual Part 2 Contains chapters 10 to 19 and appendix of the DL750 DL750P User s Manual Mainly describes operations after waveform acquisition and optional functions Contents Chapter 10 Waveform...

Страница 4: ...waveforms Setup Menu Items DL750 DL750P ScopeCoder Operation Guide IM701210 07E Communication Interface User s Manual B8023YZ A manual in PDF format that is stored in the accompanying CD ROM Describes the functions of each communication interface on the DL750 DL750P and commands Contents Chapter 1 Overview of the GP IB Interface Chapter 2 Overview of the Serial RS 232 Interface Chapter 3 Overview ...

Страница 5: ...rted display on the strain module Page 2 14 and section 5 12 Support for current probe 701931 Page 2 9 and section 3 6 G3 Support for enhanced trigger OR trigger and window trigger on Pages 2 22 and 2 26 DSP channels chapter 15 Knocking filter Section 15 6 3 10 or later Standard Added Korean to the menu languages Added Korean German Section 17 1 French and Italian to message languages 4 01 or late...

Страница 6: ...mage when all waveform display Section 13 13 section 11 1 Display Mode All is selected in the history memory function DL750P only Added a function for switching the screen display font size large Chapter 17 or small G2 Added DUTYH and DUTYL to the user defined computation Section 10 5 Applicable to DL750s on which USB Storage Yes is displayed on the overview screen that appears when you press the ...

Страница 7: ...saving data to the network drive 2 File operation Changing the file attribute deleting copying files changing the directory file name on the storage medium and creating directories 3 In the User s Manual Part 1 Printing the Screen Image Data Printing the Screen Image Data Printing on the Built in Printer Sections 12 1 and 12 2 Printing on a USB Printer Section 12 3 Printing on a Network Printer Se...

Страница 8: ...ing the USB keyboard language Section 17 3 Setting the screen color and intensity Section 17 4 Setting the backlight Section 17 5 Locking the keys Section 17 6 Ethernet interface and other operations do not have to be configured in order from previous chapter They can be configured independently The functions below that are not covered in the flow of operations in this section are not explained in...

Страница 9: ...form Parameters 11 50 11 10 Using the GO NO GO Determination I O Function 11 55 Chapter 12 Printing the Screen Image Data 12 1 Loading the Roll Paper and Paper Feeding 12 1 12 2 Printing on the Built in Printer 12 4 12 3 Printing Screen Image Data to a USB Printer 12 14 12 4 Printing the Screen Image Data on a Network Printer 12 18 Chapter 13 Saving and Loading Data 13 1 Floppy Disks Zip Disks PC ...

Страница 10: ...the Network 16 1 16 2 Setting up the TCP IP 16 3 16 3 Saving Loading Data to a Network Drive FTP Client Function 16 8 16 4 Setting up the Network Printer 16 12 16 5 Sending Periodic Mail or Action Mail SMTP Client Function 16 14 16 6 Accessing the DL750 DL750P from a PC or Workstation FTP Server Function 16 20 16 7 Using the Web Server Function 16 23 16 8 Setting the Time Difference from GMT Green...

Страница 11: ...ulate the Area of a Waveform App 7 Appendix 4 ASCII Header File Format App 9 Appendix 5 User Defined Computation App 14 Appendix 6 DSP Channel Computation Optional App 23 Appendix 7 List of Defaults App 46 Appendix 8 Assignment of Keys on the USB Keyboard App 49 Appendix 9 Waveform Acquisition Operation When the Power Supply Recovers after a Power Failure App 53 Appendix 10 Basic Defining Equation...

Страница 12: ...on Backing Up the Acquisition Memory Display Format and Waveform Mapping Display Interpolation All Point Display and Decimation Display Graticule Accumulated Display Extra Window Scale Values Waveform Labels Level Indicators and Numeric Values Translucent Mode Display Displaying the Channel Information and Expanding the Waveform Display Area X Y Waveform Display Zooming in on the Waveform Horizont...

Страница 13: ...255 701260 701261 701262 701265 or 701275 5 1 Turning Channels ON OFF 5 1 5 2 Setting T div 5 2 5 3 Setting V div 5 3 5 4 Setting the Vertical Position of Waveforms 5 5 5 5 Setting the Input Coupling 5 7 5 6 Setting the Probe Type 5 9 5 7 Setting the Bandwidth 5 10 5 8 Zooming Vertically by Setting the Zoom Rate 5 12 5 9 Zooming Vertically According to the Upper and Lower Limits of the Display Ran...

Страница 14: ...ration Measurement 5 38 Frequency Number of Rotations Period Duty Cycle Power Supply Frequency Pulse Width Pulse Integration and Velocity Measurement On the 701280 5 1 Turning Channels ON OFF 5 1 5 2 Setting T div 5 2 5 4 Setting the Vertical Position of Waveforms 5 5 5 8 Zooming Vertically by Setting the Zoom Rate 5 12 5 9 Zooming Vertically According to the Upper and Lower Limits of the Display ...

Страница 15: ...arting Stopping Waveform Acquisition 7 1 7 2 Setting the Record Length 7 3 7 3 Setting the Acquisition Mode 7 5 7 4 Acquiring Data Using Box Average 7 8 7 5 Acquiring Data Using the Sequential Store Function Single N Mode 7 10 7 6 Using the Dual Capture Function 7 11 7 7 Realtime Recording to the Internal Hard Disk Optional 7 16 7 8 Setting the Action When Waveform Display Is Updated Action on Sto...

Страница 16: ...Printer 9 1 9 2 Selecting the Recorder Mode 9 4 9 3 Setting the Record Conditions of T Y Waveform Recording 9 6 9 4 Setting the Recording Format of T Y Waveform Recording 9 8 9 5 Recording T Y Waveforms T Y Waveform Recording 9 12 9 6 Recording Numeric Values 9 14 9 7 Recording X Y Waveforms X Y Waveform Recording 9 17 9 8 Reprinting on the Built in Printer 9 21 9 9 Creating a PDF File of the Repr...

Страница 17: ...tart Point 4 Turn the jog shuttle to set the computation start point 5 Likewise set the End Point Setting the Computation 6 Press the Setup soft key The Math1 to Math8 setup dialog boxes appear 7 Use the jog shuttle and SELECT to select the Math waveform you wish to set The corresponding Math waveform setup dialog box appears Setting the Computing Operation 8 Use the jog shuttle and SELECT to set ...

Страница 18: ...nd SELECT to enter the Label according to the procedure given in section 4 2 For a description of the Label display see section 8 10 Setting Waveform Labels Turning ON OFF the Math Waveform Display 16 Use the jog shuttle and SELECT to set Display to ON or OFF As necessary set Math2 to Math8 in a similar fashion Executing the Computation 17 Press the Exec soft key Above is the menu when the user de...

Страница 19: ... The upper and lower limits are set according to the computed result Manual The upper and lower limits can be set arbitrarily The range is from 9 9999E 30 to 9 9999E 30 Setting the Unit Unit can be set arbitrarily using up to four characters The specified characters are applied to the scale values Linear Scaling When performing computation on a channel that has linear scaling set the computation i...

Страница 20: ...Start Point End Point soft key to set the jog shuttle control to Start Point 4 Turn the jog shuttle to set the computation start point 5 Likewise set the End Point Setting the Computation 6 Press the Setup soft key The Math1 to Math8 setup dialog boxes appear 7 Use the jog shuttle and SELECT to select the Math waveform you wish to set A MathX setup dialog box opens Setting the Computing Operation ...

Страница 21: ... 10 Setting Waveform Labels Turning ON OFF the Math Waveform Display 15 Use the jog shuttle and SELECT to set Display to ON or OFF Setting the Threshold Level 16 On models with the user defined computation option press the Next 1 2 soft key 17 Press the Threshold soft key 18 Use the jog shuttle and SELECT to set the trace channel on which to assign the threshold level 19 Use the jog shuttle and SE...

Страница 22: ... 11 5 Selectable Range of Cursor Position Setting the Unit Unit can be set arbitrarily using up to four characters The specified characters are applied to the scale values Linear Scaling When performing computation on a channel that has linear scaling set the computation is performed on the scaled value Notes When Performing Computation Computation is not performed again when you change Start Poin...

Страница 23: ...Turn the jog shuttle to set the computation start point 5 Likewise set the End Point Setting the Computation 6 Press the Setup soft key The Math1 to Math8 setup dialog boxes appear 7 Use the jog shuttle and SELECT to select the Math waveform you wish to set A MathX setup dialog box opens Setting the Computing Operation 8 Use the jog shuttle and SELECT to set Operation to PS S1 Selecting the Channe...

Страница 24: ...k 2k 5k 10k 20k 50k or 100k Selecting the Time Window 18 While the jog shuttle control is set to FFT Points press the FFT Points FFT Window soft key again The FFT Window selection menu appears 19 Select the time window from Rect Hanning FlatTop and Exponential You can select Exponential only when the user defined computation option is installed 20 If you selected Exponential press the Exponential ...

Страница 25: ... of FFT points to 50k or greater only Math1 and Math2 can be used In this case Math3 to Math8 cannot be used even in computations other than FFT Example 1 Math1 C1 C2 Math2 PS LOGMAG M1 Math3 C3 C4 Math1 to Math3 The number of FFT points is 50k Computes only Math1 and Math2 Example 2 Math1 C1 Math2 C2 Math3 The number of FFT points is 50k Computes only Math1 and Math2 Selecting the Time Window Sel...

Страница 26: ...creen shows Rms overall value For details on the automated measurement of waveform parameters see section 11 6 For details on the overall value see page App 19 PSD is available only on models with the user defined computation option see section 10 5 Note If Window is set to Exponential the overall value is not displayed Linear Scaling When performing computation on a channel that has linear scalin...

Страница 27: ...hem If you select ON proceed to step 3 Setting the Computation Start and End Points 3 Press the Start Point End Point soft key to set the jog shuttle control to Start Point 4 Turn the jog shuttle to set the computation start point 5 Likewise set the End Point Setting the Computation 6 Press the Setup soft key The Math1 to Math8 setup dialog boxes appear 7 Use the jog shuttle and SELECT to select t...

Страница 28: ...n the user defined computation option is installed The menu on models without the option is as follows 1 Phase Shift 2 Threshold 3 Start Point End Point 4 Exec If the time base is set to internal clock If the time base is set to external clock the setup menu used to set the number of data points for shifting the phase appears Turning ON OFF the Math Waveform Display 13 Use the jog shuttle and SELE...

Страница 29: ...ution 1 sample rate The sample rate varies depending on the record length or T div setting For details see appendix 1 Relationship between the Time Axis Setting Sample Rate and Record Length When the Time Base Is Set to External Clock Selectable range record length 2 to record length 2 Resolution 1 When a Waveform That Results by Offsetting the CH1 Waveform by 5 ms Is Set to Math1 Phase Shift CH1 ...

Страница 30: ...to set the jog shuttle control to Start Point 4 Turn the jog shuttle to set the computation start point 5 Likewise set the End Point Setting the Computation 6 Press the Setup soft key The Math1 to Math8 setup dialog boxes appear 7 Use the jog shuttle and SELECT to select the Math waveform you wish to set A MathX setup dialog box opens Setting the Computing Operation 8 Use the jog shuttle and SELEC...

Страница 31: ...ect Auto you cannot set Upper and Lower Setting the Unit 14 Use the jog shuttle and SELECT to set the Unit using up to four characters according to the procedure given in section 4 2 Setting the Label 15 Use the jog shuttle and SELECT to enter the Label according to the procedure given in section 4 2 For a description of the Label display see section 8 10 Setting Waveform Labels Turning ON OFF the...

Страница 32: ... or FILT2 in the equation set the digital filter 22 Press the Filter soft key The filter setup dialog box appears 23 Use the jog shuttle and SELECT to set Filter Select to FILT1 or FILT2 24 Use the jog shuttle and SELECT to select Filter Type from Gauss Sharp and IIR 25 Press the Filter Band soft key to select Low Pass High Pass or Band Pass 26 Use the jog shuttle and SELECT to set CutOff If you s...

Страница 33: ... constants K1 to K8 Setting Average and Peak Computation 31 Press the Average soft key The average setup dialog box appears 32 Use the jog shuttle and SELECT to select Average Mode from OFF Linear Exp Cycle and Peak If you select Peak the operation ends here When Linear or Exp Is Selected 33 Use the jog shuttle and SELECT to set Average Domain to Time or Freq 34 Use the jog shuttle and SELECT to s...

Страница 34: ...e phase of each waveform If the time base is set to internal clock Int set the time for shifting the phase If the time base is set to external clock Ext set the number of data points for shifting the phase Executing the Computation 38 Press the Exec soft key DSP1 to DSP6 are optional If the time base is set to internal clock If the time base is set to external clock the setup menu used to set the ...

Страница 35: ...s the C1 2 C2 2 of the specified waveform FV FV C1 Displays the inverse of the PWHH of the pulse width PWHH PWHH M1 Displays the pulse width computation from the rising edge to the next rising edge PWHL PWHL C2 Displays the pulse width computation from the rising edge to the next falling edge PWLH PWLH C1 Displays the pulse width computation from the falling edge to the next rising edge PWLL PWLL ...

Страница 36: ... of the two specified waveforms coherence function Waveforms and Variables to Be Computed CH waveforms C1 to C16 DSP channel waveform DSP1 to DSP optional Math waveform M1 to M7 variable T the total number of data points in the time direction is defined to be T It is displayed as a rising line on the screen Combinations of Computing Equations That Are Not Allowed An equation of a large number cann...

Страница 37: ...le Count in the range 10 to 1800 This number is applied to the data from the start to the end of the computed data but the remaining data that cannot be divided by the Cycle Count are ignored Cycle average cannot be performed on an FFT waveform For peak computation the maximum value at each point of the computed data is determined and the waveform is displayed For each computation the new computed...

Страница 38: ...scription of the FFT refer to points FFT frequency band and window in Section 10 3 Performing Power Spectrum Computation FFT For details on digital filters and the FFT refer to Appendix 5 Phase Shift The phase of a specified waveform is shifted The amount of shift is specified in the phase shift setup menu The selectable range is Time div 5 the resolution is 1 sample rate Linear Scaling When perfo...

Страница 39: ...3 DSP 4 EXP GO NO GO ACTION FILE SHIFT Recalling Data from the History Memory 1 Press HISTORY 2 Press the Select Record soft key 3 Turn the jog shuttle to set the record No you wish to recall Set the record No in the range of Start Record to End Record 4 Press the Display Mode soft key to select One Data Accumulation Display 5 Press the Start Record End Record soft key to set the jog shuttle contr...

Страница 40: ...5 to 7 are displayed averaged To abort the average display press the Display Mode soft key to select One Displaying a List of Time Stamps 13 Press the Show Map soft key A list of acquired data numbers and the time at acquisition end are displayed 14 Turn the jog shuttle to select the data you wish to display and press SELECT Clearing the History Memory 15 Press the History Clear soft key All the w...

Страница 41: ...ed Show Map A List of Time Stamps You can list the number of the waveform data stored in the acquisition memory and the time at acquisition end One screen displays 75 data points of information You can scroll through the data by using the jog shuttle Clearing the History Memory Clears all the waveforms in the acquisition memory Cleared waveforms cannot be recovered Notes When Setting the History M...

Страница 42: ...ntent remains unchanged after acquisition is restarted However for average display computation is not performed again when you specify a different record The time displayed in Show Map is the waveform trigger time The information varies depending on the trigger mode as follows Trigger Mode Condition Time Displayed in Show Map Auto Auto Level Roll mode Stop time Single Roll mode trigger not activat...

Страница 43: ...DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press HISTORY 2 Press the Search Mode soft key The search mode menu appears 3 Press the Zone soft key Setting the Search Zone 4 Press the Search Setup soft key The search setup menu appears 5 Press the Select Zone soft key The search condition selection menu appears 6 Press any of the Zone1 to Zone4 soft keys to select the search condition Setting the S...

Страница 44: ...ge of the search window 15 Repeat steps 5 to 13 to set Zone1 to Zone4 Setting the Search Logic 16 Press the Logic soft key to select AND or OR Executing the Search 17 Pressing the Search Exec soft key to execute the search While search is in execution is displayed at the upper left corner of the screen Displaying the Waveform That Are Found 18 Press the ESC to return to the HISTORY menu 19 Press t...

Страница 45: ...ls are also displayed Vertical Range of Search Window Upper Lower The selectable range is 5 divisions The resolution is 0 01 divisions Upper must always be greater than or equal to Lower Horizontal Range of Search Window Left Right The selectable range is 5 divisions The resolution is 10 division display record length Right must always be greater than or equal to Left Logic AND Searches for wavefo...

Страница 46: ...IC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press HISTORY 2 Press the Search Mode soft key The search mode menu appears 3 Press the Parameter soft key Setting the Search Zone 4 Press the Search Setup soft key The search setup menu appears 5 Press the Select Param soft key The search condition selection menu appears 6 Press any of the Param1 to Param4 soft keys to select the sea...

Страница 47: ...e measuring range Pressing RESET resets the value to default 19 Press the Time Range1 Time Range2 soft key to set the jog shuttle control to Time Range2 20 Turn the jog shuttle to set the right edge of the measuring range Pressing RESET resets the value to default Executing the Search 21 Pressing the Search Exec soft key to execute the search While search is in execution is displayed at the upper ...

Страница 48: ...The channels that can be specified are CH1 to CH16 and DSP1 to DSP6 optional Waveforms of other channels are also displayed Condition Range Upper Lower Set the range that defines the specified parameter s condition Logic AND Searches for waveforms that meet all search conditions from Param1 to Param4 OR Searches for waveforms that meet any one of the search conditions from Param1 to Param4 Paramet...

Страница 49: ...Type 2 Press the Type soft key The search type selection menu appears 3 Press the Edge soft key Setting the Search Condition 4 Press the Setup soft key The search condition setup dialog box appears Turn the jog shuttle to set the parameter Setting the Search Source Channel 5 Use the jog shuttle and SELECT to select Source Setting the Level 6 Use the jog shuttle and SELECT to set Level Pressing RES...

Страница 50: ...indow soft key to select Z1 or Z2 Executing the Search 14 Pressing the Exec soft key to execute the search The Exec soft key changes to Abort To abort the search press the Abort soft key The search results are displayed in the zoomed waveform display position selected in step 11 You can search 1000 times using the same conditions While search is in execution is displayed at the upper left corner o...

Страница 51: ...ition of the Search Results When Mode in the ZOOM Menu Is Set to Z1 Z2 or Main Z1 Z2 5 Press the Result Window soft key to select Z1 or Z2 Changing the Magnification and Display Position 6 As with the zoomed waveform you can change the zoom rate of Z1 and Z2 by pressing the Z1 Mag Z2 Mag soft key and turning the jog shuttle 7 As with the zoomed waveform you can move the section that is being zoome...

Страница 52: ...using the jog shuttle Setting the Display Position of the Search Result Window When Mode in the ZOOM menu is set to Z1 Z2 or Main Z1 Z2 6 Press the Result Window soft key to select Z1 or Z2 Executing the Search 7 Press the Exec soft key The search is executed The Exec soft key changes to Abort To abort the search press the Abort soft key The search results are displayed in the zoomed waveform disp...

Страница 53: ...the number of times the waveform passes from below the specified level to above the specified level Search by the number of times the waveform passes from above the specified level to below the specified level Hysteresis Set the hysteresis Count Set the number of times or is to be met The selectable range is 1 to 1000000 Start Point Set the start position of the search The selectable range is from...

Страница 54: ...steresis In addition in the determination of logic waveforms the determination is performed two points after the detected position Search start position When the edge is set to rising Detection position Detection position Search restart position Not detected here Detection position Auto Scroll Set the scroll speed using 10 levels from 1 to 10 The speed increases as the number gets larger You can o...

Страница 55: ... 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press CURSOR Selecting the Cursor Type 2 Press the Type soft key The cursor type selection menu appears 3 Press the Horizontal soft key Selecting the Waveform to Be Measured 4 Press the Trace soft key The trace selection menu appears 5 Press the soft key corresponding to the desired wa...

Страница 56: ...asured to All LogicA LogicB or LogicA LogicB proceed to step 6 If not proceed to step 9 Setting the Logic When Trace Is Set to All LogicA LogicB or LogicA LogicB 6 Press the Logic Setup soft key The logic setup menu appears Selecting the Notation of Cursor Measurement Values 7 Use the jog shuttle and SELECT to set Format to Binary or Hexa Note The notation selected in step 7 applies to the notatio...

Страница 57: ...3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press CURSOR Selecting the Cursor Type 2 Press the Type soft key The cursor type selection menu appears 3 Press the Marker soft key Selecting the Marker 4 Press the Select soft key to select the desired marker from M1 to M4 Selecting the Waveform to Be Measured 5 Press the Trace soft key The trace selection menu appears 6 Press the soft key corresponding to...

Страница 58: ...the Waveform to Be Measured 4 Press the Trace soft key The trace selection menu appears 5 Press the soft key corresponding to the desired waveform to select the waveform to be measured Moving the Cursor 6 Press the Cursor1 Cursor2 soft key to set the jog shuttle control to Cursor1 7 Turn the jog shuttle to move Cursor1 8 Likewise move Cursor2 If the jog shuttle control is set to both Cursor1 and C...

Страница 59: ...O ACTION FILE SHIFT 1 Press CURSOR Selecting the Cursor Type 2 Press the Type soft key The cursor type selection menu appears 3 Press the H V soft key Selecting the Waveform to Be Measured 4 Press the Trace soft key 5 Press the soft key corresponding to the desired waveform to select the waveform to be measured Moving the Cursor 6 Press the Cursor1 Cursor2 soft key to set the jog shuttle control t...

Страница 60: ...ARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Follow steps 1 3 on the previous pages to set the Type to Vertical Marker or Degree Setting Jumps 2 Press the Cursor Jump soft key A menu for selecting the cursor to be jumped and the jump destination appears 3 Press the soft key corresponding to the type of jump to select th...

Страница 61: ...OR Selecting the Cursor Type 2 Press the Type soft key The cursor type selection menu appears 3 Press the Horizontal soft key Selecting the Waveform to Be Measured 4 Press the Trace soft key 5 If X Axis of the X Y menu is set to Single use the jog shuttle and SELECT to select the trace If X Axis is set to Quad press the soft key corresponding to the X Y waveform XY1 to XY4 to select the waveform t...

Страница 62: ...he cursor type selection menu appears 3 Press the Vertical soft key Selecting the Waveform to Be Measured 4 Press the Trace soft key 5 If X Axis of the X Y menu is set to Single the channel specified by X trace of the X Y menu is displayed Since this setting is for viewing purpose only you cannot change it If X Axis is set to Quad press the soft key corresponding to the X Y waveform XY1 to XY4 to ...

Страница 63: ...s the Type soft key The cursor type selection menu appears 3 Press the H V soft key Selecting the Waveform to Be Measured 4 Press the Trace soft key 5 If X Axis of the X Y menu is set to Single use the jog shuttle and SELECT to select the trace If X Axis is set to Quad press the soft key corresponding to the X Y waveform XY1 to XY4 to select the waveform to be measured Moving the Cursor 6 Press th...

Страница 64: ...g the Cursor Type 2 Press the Type soft key The cursor type selection menu appears 3 Press the Marker soft key Selecting the Waveform to Be Measured 4 Press the Trace soft key 5 If X Axis of the X Y menu is set to Single use the jog shuttle and SELECT to select the trace If X Axis is set to Quad press the soft key corresponding to the X Y waveform XY1 to XY4 to select the waveform to be measured M...

Страница 65: ...etween the Y axis values of M1 and M3 Y4 The difference between the Y axis values of M1 and M4 X1 to X4 The X axis values of M1 to M4 X2 The difference between the X axis values of M1 and M2 X3 The difference between the X axis values of M1 and M3 X4 The difference between the X axis values of M1 and M4 Angle Cursor Degree Set the measurement zero point position of reference cursor Ref1 and the en...

Страница 66: ...laying the X Y Waveform H Cursor Can be set in the range from 5 to 5 divisions from the center of the screen The resolution is 0 01 divisions V Cursor Marker Cursor and Angle Cursor Can be set in the range from 5 to 5 divisions from the center of the screen The resolution is T div 10 display record length Movement Range of the Cursors When Displaying the X Y Waveform H Cursor V Cursor and H V Curs...

Страница 67: ...order is A1 A8 B1 B8 Binary Y1 01001010 Y2 10110010 Hexa Y1 4A Y2 B2 When the order is B8 B1 A8 A1 Binary Y1 01010010 Y2 01001101 Hexa Y1 52 Y2 4D When LogicA or LogicB is measured by itself and OFF bits exist Cursor 1 Cursor 2 0 1 3 4 6 7 When the order is A1 A8 B1 B8 Binary Y1 01 01 10 Y2 10 10 10 Hexa Y1 16 Y2 2A When the order is B8 B1 A8 A1 Binary Y1 01 10 10 Y2 01 01 0 Hexa Y1 1A Y2 15 When ...

Страница 68: ...n the acquisition memory not on the displayed data Since 1001 points along the time axis are used to displayed the waveform the number of acquired data points is equal to record length 1 001 If the record length is set to 10 kW the number of acquired data points is 10010 Therefore if the record length is set to 10 kW 10 points of measured data will exist at the same position on the screen The curs...

Страница 69: ...NO GO ACTION FILE SHIFT 1 Press MEASURE 2 Press the Mode soft key and press the ON soft key Selecting the Measurement Parameter 3 Press the Item Setup soft key The measurement parameter setup dialog box appears Selecting the Waveform to Be Measured 4 Press the Trace soft key The trace selection menu appears 5 Use the jog shuttle and SELECT to select waveform to be measured Selecting the Measuremen...

Страница 70: ...the jog shuttle and SELECT to set Polarity under Measure to rising edge or falling edge 13 Use the jog shuttle and SELECT to set Edge Count under Measure 14 Use the jog shuttle and SELECT to select whether the trace or the trigger is to be the reference If you select Trace proceed to step 15 15 Use the jog shuttle and SELECT to set Trace under Reference 16 Use the jog shuttle and SELECT to set Pol...

Страница 71: ... soft key 23 Press the Trace soft key The trace selection menu appears 24 Press the soft key corresponding to the desired waveform to select the target waveform Setting the Distal Mesial and Proximal Unit 25 Press the Dist Prox Mode soft key to set the unit for distal mesial and proximal points to or Unit If the target waveform was set to DSP1 to DSP6 optional in steps 23 and 24 only is selectable...

Страница 72: ...age V Low Level Voltage V Amplitude High Low V MAX MIN 2 P P Max Min Rms1 Avg Sdev SDv 2 Ovr shoot Ovr 1 Ovr shoot Ovr 1 High Low Amp Mid 1 If Rms is ON on the channels Math1 to Math8 on which power spectrum computation PS or PSD is selected the screen shows Rms overall value For details on the power spectrum computation see sections 10 3 and 10 5 For details on the overall value see page App 19 2...

Страница 73: ...x 3 How to Calculate the Area of a Waveform Setting the Delay The time difference between the rising or falling edges of trace waveforms or trigger points is called the delay between channels Reference Waveform Measurement Waveform 1 count N1 count 1 count N2 count Delay between Channels Edge Polarity Edge Count Setting Example of Reference Waveform Setting Example of Measurement Waveform Measurem...

Страница 74: ...is analogous to the concept of the selectable range of cursor display position in cursor measurement For details see section 11 5 Selectable Range of Cursor Position Setting the Distal Mesial and Proximal Unit Dist Prox Mode Select the method of assigning the three levels that are used as references in measurements such as the rise and fall times The distal mesial and proximal values are set in te...

Страница 75: ...ssible If there are two or more cycles of a waveform in the measurement range the measurement is made on the first waveform Automated measurement is not possible on logic waveforms If automated measurement is made on waveforms that are measured using the realtime recording function the execution of the automated measurement takes a long period due to the hard disk access Depending on the condition...

Страница 76: ... MEASURE 2 Press the Mode soft key to select Statistics 3 Press the Item Setup soft key The measurement parameter dialog box and the measurement channel menu appear 4 Press the Trace soft key and use the jog shuttle and SELECT to select the measurement channel 5 Turn the jog shuttle to move the cursor to the parameter you wish to turn ON 6 Press SELECT to turn on the parameter selected in step 5 Y...

Страница 77: ...ll Clear You can copy the current parameter settings to all traces by selecting Copy to All Trace 7 Repeat steps 4 to 6 as many times as necessary Press ESC 8 Press the Cycle Trace soft key The cycle trace menu appears 9 Press the soft key corresponding to the channel to be used to determine the cycle If Own is specified the cycle is determined on each waveform for statistical processing The setti...

Страница 78: ...s SELECT to turn on the parameter selected in step 5 You can turn OFF all parameters at once by pressing the All Clear You can copy the current parameter settings to all traces by selecting Copy to All Trace 7 Repeat steps 4 to 6 as many times as necessary Press ESC The setting of other parameters is the same as the automated measurement of waveform parameters see step 8 and following steps in sec...

Страница 79: ...ent parameter the maximum minimum average standard deviation and the number of measured values used in the statistical processing are displayed at the bottom section of the screen The result of statistical processing that can be displayed is three parameters of automated measurement If you selected four or more parameters for automated measurement the first three parameters in the automated measur...

Страница 80: ...ame fashion as the Period for the waveform parameter You can select whether to apply the cycle of the specified waveform to all waveforms or determine the cycle for each waveform CH Math DSP Performs automated measurement of waveform parameters on all target waveforms per cycle of the specified channel and performs statistical processing Own Determines the cycle for each target waveform performs a...

Страница 81: ...d The maximum and minimum values of each waveform parameter are displayed using maximum and minimum If there are multiple points that are of the same value the maximum and minimum values are marked on the oldest data The number of data points that can be listed is 48000 If this value is exceeded the most recent 48000 points of automated measurement parameters of history waveforms or data are displ...

Страница 82: ...etermination Zone 4 Press the Edit Zone soft key 5 Press any of the Zone1 to Zone6 soft keys to select the Zone 6 Press the New soft key A menu for selecting the reference waveform for creating the zone appears 7 Press the soft key corresponding to the reference waveform The zone edit menu appears Editing the Entire Zone 8 If Edit is not set to Whole press the Edit soft key to select Whole 9 Press...

Страница 83: ... destination for registering the zone 22 Press the Store Exec soft key to confirm the registration Correcting a Preexisting Determination Zone 23 Select the determination zone you wish to correct according to steps 4 and 5 24 Correct the zone according to steps 8 to 22 Setting the Determination Waveform 25 Press the ESC or carry out an equivalent operation to return to the GO NO GO menu 26 Press t...

Страница 84: ... ASCII or Float Setting the Determination Range 39 Press the Time Range1 Time Range2 soft key to set the jog shuttle control to Time Range1 40 Turn the jog shuttle to set the determination start point 41 Likewise set Time Range2 determination end point Executing the GO NO GO Determination 42 Press the Exec soft key to execute the GO NO GO determination The soft key changes to Abort Waveform acquis...

Страница 85: ...t be made if the target waveform is set to strain or temperature Setting the Determination Conditions Setup Selecting the Target Waveform Trace Select the waveform from CH1 to CH16 and Math waveforms Setting the Determination Mode IN GO condition when all the applicable waveforms enter the determination zone NO GO if any of the waveforms exists the determination zone OUT GO condition when all the ...

Страница 86: ...ng format to the destination FD Zip disk PC card internal HD optional SCSI device USB storage device specified in the FILE menu The save format is synchronized to data type see section 13 7 on the FILE menu Buzzer Sounds a buzzer Send Mail Sends an e mail message to a specified address when the Ethernet interface option is installed For the procedure in setting the address see section 16 5 Sending...

Страница 87: ...ng is in progress or when waveforms are being acquired using the dual capture function If any of the following actions is activated while the DL750 DL750P is being accessed through the FTP server function or the Web server function the action is not executed until the access is finished Printing saving of the screen image data and saving of the waveform data Notes When Action Is Set to Save to Fil...

Страница 88: ...tion mode appears 3 Press the Parameter soft key Setting the Determination Conditions 4 Press the Setup soft key A criteria setup dialog box appears Use the jog shuttle or arrow keys to move the cursor to the item you wish to set Selecting the Target Waveform 5 Use the jog shuttle and SELECT to set Trace of number 1 Selecting the Determination Criteria 6 Use the jog shuttle and SELECT to set Mode ...

Страница 89: ...e Time Range1 Time Range2 soft key to set the jog shuttle control to Time Range1 20 Turn the jog shuttle to set the determination start point 21 Likewise set Time Range2 determination end point Executing the GO NO GO Determination 22 Press the Exec soft key to execute the GO NO GO determination The soft key changes to Abort Waveform acquisition stops automatically when determination is finished To...

Страница 90: ...f the parameter conditions 1 to 16 types is met Action Condition ActCondition Always Always executes the action Failure Execute the action when the GO condition is not met Success Execute the action when the GO condition is met When Always is selected the operation specified by Action is executed each time the trigger occurs This function is useful such as when you wish to print the screen image d...

Страница 91: ...The save format is synchronized to data type see section 13 7 on the FILE menu Buzzer Sounds a buzzer Send Mail Sends an e mail message to a specified address when the Ethernet interface option is installed For the procedure in setting the address see section 16 5 Sending Periodic Mail or Action Mail Setting the Determination Range Time Range1 Time Range2 By default the determination range is 5 di...

Страница 92: ...ge The determination period is synchronized to the trigger However triggers are not accepted while the action after determination is being carried out Determination is not possible when realtime recording is in progress or when waveforms are being acquired using the dual capture function If any of the following actions is activated while the DL750 DL750P is being accessed through the FTP server fu...

Страница 93: ...s wire the pins according to the following figure I O Level Within 0 to 5 V threshold level TTL Pin Arrangement 6 1 1 Pin No Signal Name 2 3 4 5 6 NC no connection START IN GO OUT GO NO GO NOGO OUT IN Connector on the DL OUT OUT Start at low Active low Active low GND SPEAKER Input Signal START IN Negative Logic This signal is used when performing GO NO GO determination by synchronizing to an exter...

Страница 94: ...or more Remains at low output until the next determination can be accepted The time is extended while outputting to the built in printer or internal storage medium When Remote Start is OFF START IN is not used GO OUT and NO GO OUT are output using the internal determination timing GO NO GO Cable 366973 Sold Separately Use this cable only for the GO NO GO determination on the DL750 DL750P See the f...

Страница 95: ...ool dry and dark place After opening the package use it quickly If the paper is left in contact with plastic film such as a vinyl chloride film or Scotch tape containing plasticizers for an extended time the paper will lose some of its ability to reproduce color If you are going to store the paper in a folder for example use a folder made of polypropylene When using glue on the paper do not use gl...

Страница 96: ...e of the roll paper evenly in the space between the roller and the black guide then rotate the paper feed knob away from you until about 10 cm of the paper is showing from the top of the roller 4 Move the release arm to the FREE position and straighten out the paper Then move the release arm to the HOLD position The printing will fail with an error message if the release arm is in the FREE or MAN ...

Страница 97: ...to the steps given below If the paper is not being fed evenly continue to feed the paper for approximately 30 cm The paper will straighten out Feeding the Paper You can feed the paper to check whether the roll paper has been loaded properly or to skip dirty sections Procedure FILE SHIFT HELP MISC NUM KEY PROTECT VOICE MEMO IMAGE SAVE PRINT SNAPSHOT CLEAR TRACE MENU MENU 1 Press SHIFT PRINT 2 Press...

Страница 98: ...5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT Selecting the Printer 2 Press the Print to soft key The printer selection menu appears Net Print appears only when the Ethernet interface option is installed 3 Press the Printer soft key Setting the Output Format 4 Press the Format soft key The output format selection menu appears 5 Press the Normal Fi...

Страница 99: ...to step 10 Zoom Print When Zoom Print Is Selected in Step 5 Setting Zoom Box Z2 6 Press the Z2 Mag Z2 Position soft key to set the jog shuttle control to Time Z2 Mag 7 Turn the jog shuttle to set the zoom rate of the Z2 zoom box 8 Likewise set the zoom position of the Z2 zoom box with Z2 Position Proceed to step 10 Note In zoom print the range of zoom box Z2 10 divisions is printed The Z2 Mag Z2 P...

Страница 100: ...omment setting is linked with the PRINT menu Comment setting DL750P 10 Press the Print Setup soft key Setting the Print Format 11 Use the jog shuttle and SELECT to select Format from Single 1 division to Hexadecimal 16 divisions Note The print format setting is linked with the DISPLAY menu Format setting Setting the Extra Area 12 Use the jog shuttle and SELECT to set Extra Area to ON or OFF DL750 ...

Страница 101: ... Scale 18 Use the jog shuttle and SELECT to set Width to 1div or 10mm Proceed to step 19 Note The grid setting is linked with the DISPLAY menu Graticule setting However if OFF is selected the DISPLAY menu is set to Setting Details Setting the Print Interval of Scale Values 19 Use the jog shuttle and SELECT to set Scale to OFF 200mm 400mm or 800mm Setting the Print Interval of Channel Labels 20 Use...

Страница 102: ...dure in section 4 2 Setting a Comment 26 Use the jog shuttle and SELECT to select Comment Then enter the comment text you wish to print using up to 20 characters according to the procedure in section 4 2 Note The comment setting is linked with the PRINT menu Comment setting Previewing the Print Image 27 Press the Preview soft key The print image is displayed on the screen Turn the jog shuttle to c...

Страница 103: ...ges as shown below Normal waveform Print example Page 1 Page 2 Page 3 Zoom Print The range of zoom box Z2 of the zoom function see section 8 5 is magnified and printed Zoom box Z2 TIME DIV 10 ms div ZOOM menu Z2 Mag 5 ms div Z2 Position 0 5 div PRINT menu Mag 2 ms div Z2 Zoom waveform Main Normal waveform Print example Page 1 Page 2 Page 3 Waveform in Z2 is magnified to 2 ms div Printed on 3 pages...

Страница 104: ...ilt in printer Single 1 division Quad 4 divisions Dual 2 divisions Octal 8 divisions Triad 3 divisions Hexadecimal 16 divisions The format setting is linked with the DISPLAY menu Format setting Extra Area The extra area can be set only when the format is set to Single Dual Triad or Quad When the Format Is Single If extra area is turned ON the top 16 cm of the print area 20 cm is used to print wave...

Страница 105: ...he graticule lines that are printed see page 9 10 1div Graticule obtained by dividing the print zone into 10 areas 10mm mm graticule type Details Print Interval of Scale Values Scale Select the interval for the scale printed at the top and bottom edges of the print area from OFF 200 mm 400 mm or 800 mm If OFF is selected the scale is not printed Print Interval of Channel Labels CH Label Select the...

Страница 106: ...een the grids Note If all of the conditions below are met only up to 67 characters of CH Message are printed Format Single Dual Triad Quad Extra Area OFF Scale Other than OFF Comment A comment string of up to 20 characters can be printed at the top section of the print area The comment setting is linked with the PRINT menu Comment setting Preview A preview of the print image data can be displayed ...

Страница 107: ...12 13 IM 701210 06E Printing the Screen Image Data 12 Examples of Fine Print and Zoom Print DL750 Trigger time T div Comment DL750P Trigger time T div Comment 12 2 Printing on the Built in Printer ...

Страница 108: ...cable For details see the explanation in the next section Selecting the Printer 2 Press SHIFT PRINT 3 Press the Print to soft key The printer selection menu appears Net Print appears only when the Ethernet interface option is installed 4 Press the USB soft key Confirming the Printer That Is Connected 5 Press the Select soft key The USB Device List appears Check the printer that is connected Note Y...

Страница 109: ...mment string according to the procedure given in section 4 2 Setting the Print Resolution When Format Is BJ 11 Press the Resolution soft key The print resolution setup menu appears 12 Press any of the soft keys corresponding to 180 dpi 300 dpi 360 dpi and 600 dpi Executing the Print Operation 13 Press PRINT The screen image data is printed on the USB printer To abort printing press PRINT while pri...

Страница 110: ...type B connector to the printer When the power switch is ON the printer is detected and enabled approximately 6 s after it is connected USB connection USB printer DL750 DL750P FILE SHIFT HELP MISC NUM KEY PROTECT VOICE MEMO IMAGE SAVE PRINT ESC MEASURE CURSOR RESET SELECT CH ALL CH MODE POSITION SIMPLE ENHANCED ACQ START STOP SETUP DISPLAY ZOOM DUAL CAPTURE HISTORY MATH 1 CH 2 CH 3 CH 4 CH 5 CH 6 ...

Страница 111: ...nu Comment setting Color Select from the following ON Print the data using colors similar to the screen No background color and grid printed in black OFF Prints the image using the same colors as the image printed using the built in printer Notes When Printing on the USB Printer Images may not print properly on some printers Use USB printers that have been tested for compatibility For details on U...

Страница 112: ...twork printer according to the procedures given in section 16 2 Configuring the TCP IP and section 16 4 Configuring the Network Printer Selecting the Printer 2 Press SHIFT PRINT 3 Press the Print to soft key The printer selection menu appears Net Print appears only when the Ethernet interface option is installed 4 Press the Net Print soft key Selecting the Output Format 5 Press the Format soft key...

Страница 113: ... printer formats are supported ESC P ESC P2 LIPS3 PCL5 BJ PostScript Output Resolution When Printing Using the BJ Format When printing the screen image data to a BJ printer select the output resolution from 180 dpi 300 dpi 360 dpi and 600 dpi Comment A comment string of up to 20 characters can be printed at the bottom right section The comment setting is linked with the PRINT menu Comment setting ...

Страница 114: ...disk from the side with the shutter Insert the disk until the eject button pops out Removing the Disk from the Floppy Disk Drive Check that the access indicator is turned OFF and press the eject button Label side Eject button Access indicator CAUTION Removing the floppy disk while the access indicator is blinking can damage the magnetic head of the floppy disk drive or destroy the data on the flop...

Страница 115: ... Zip Drive With the label facing toward you insert the disk from the side with the shutter Removing the Zip Disk from the Zip Drive With the DL750 turned ON check that the access indicator is OFF and press the eject button If you need to use the Zip disk again wait at least three seconds after removing it before reinserting it into the drive Eject button Access indicator Label side 13 1 Floppy Dis...

Страница 116: ...750 is installed using the stand For the installation position see section 3 2 When turning ON OFF the DL750 have the Zip disk removed from the drive Do not insert the Zip disk into the drive or remove the Zip disk from the drive while the DL750 is starting up after turning ON the power see section 3 4 Power Up Operation Doing so can damage the disk The access indicator illuminates immediately aft...

Страница 117: ... properly Check it beforehand Inserting the PC Card With the label side of the PC card facing toward you insert the PC card into the drive The PC card drive is located on the left side panel of the DL750 DL750P Ejecting the PC Card Check that the PC card is not being accessed and press the PC card ejection button to the right of the drive Eject button Label side CAUTION The DL750 DL750P may malfun...

Страница 118: ... 06E Saving and Loading Data 13 General Handling Precautions of PC Cards For the general handling precautions of the PC card read the instruction manual that came with the PC card 13 1 Floppy Disks Zip Disks PC Cards ...

Страница 119: ... FILE SHIFT HELP MISC NUM KEY PROTECT VOICE MEMO IMAGE SAVE PRINT SNAPSHOT CLEAR TRACE MENU MENU 1 Press MISC 2 Press the Next 1 2 soft key 3 Press the Others soft key 4 Press the HDD Motor soft key to select ON or OFF Explanation You can turn ON OFF the motor rotation of the internal hard disk on the DL750 DL750P If you turn OFF the internal hard disk motor the internal hard disk cannot be access...

Страница 120: ...4 Port 2 Pin No Signal Name 1 VBUS 5 V 2 D Data 3 D Data 4 GND Ground Connecting the USB Storage Device When connecting a USB storage device directly connect the printer to the DL750 DL750P using a USB cable as shown below You can connect the USB cable regardless of whether the power switch on the DL750 DL750P is ON or OFF supports hot plugging When the power switch is ON the USB storage device is...

Страница 121: ...be connected simultaneously to the two ports CAUTION Do not remove the USB storage device or turn OFF the power when the USB storage device is being accessed If you do the data on the USB storage device may be destroyed An access icon is displayed at the upper left corner of the screen while the USB storage device is being accessed General Handling Precautions of USB Storage Devices For the genera...

Страница 122: ...n the left side panel of the DL750 DL750P 2 Turn ON the SCSI device and the DL750 DL750P in that order To format the disk follow the procedure described in the section 13 5 Formatting the Storage Medium Connectable SCSI Devices SCSI devices that can be connected to the DL750 DL750P are MO disk drives and Zip drives For details on which devices can be connected contact your nearest YOKOGAWA dealer ...

Страница 123: ... CH 8 CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 DELAY MANUAL TRIG V DIV TIME DIV TRIGGER TRIG D VERTICAL HORIZONTAL CAL X Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the Utility soft key The Utility setup menu and the File List window appear Selecting the Storage Medium to Be Formatted 3 Pre...

Страница 124: ... shuttle to set the number of partitions Proceed to step 9 Note The number of partitions is 1 for removable disks such as SCSI and Zip disks Selecting the Number of Partitions of the Internal Hard Disk Optional Selecting the Number of Partitions 6 Press the Format soft key The format selection menu appears 7 Press the Partition soft key 8 Turn the jog shuttle to set the number of partitions to 2 o...

Страница 125: ...e medium is being formatted an icon corresponding the medium FD Zip disk PC card external SCSI device internal HD or USB storage device being formatted is displayed at the upper left corner of the screen Select Cancel and press SELECT to cancel the format operation Viewing the Media Information Select the storage medium according to steps 1 to 5 Press the Media Info soft key The information about ...

Страница 126: ...tting an External SCSI Device The formats of the disk that are connected via the SCSI option are as follows MO Semi IBM format Handled as a removable disk Zip FDISK 1 partition Handled as a fixed disk Formatting the Internal Hard Disk Optional Selecting the Number of Partitions You can set the number of partitions to 2 or 3 Setting the Realtime Recording Area You can set the realtime recording are...

Страница 127: ...disk It takes a few seconds to format a PC card It takes approximately 30 s to 1 minute to format the internal hard disk optional You cannot format a floppy disk if the write protect is ON Do not format a disk while the DL750 DL750P and a PC is connected via a SCSI cable Floppy disks that are formatted to formats other than those listed in this section cannot be used If an error message is display...

Страница 128: ...enu appears Changing the ID Number of the DL750 DL750P 3 Press the Own ID soft key 4 Turn the jog shuttle to select a value in the range of 0 to 7 Changing the ID Number of the Internal Hard Disk 5 Press the Internal ID soft key 6 Turn the jog shuttle to select a value in the range of 0 to 7 Executing the ID Number Change 7 Press the Initialize SCSI soft key The SCSI ID is changed to the selected ...

Страница 129: ...rd disk optional can be set in the range of 0 to 7 The default value is 4 Notes When Setting the ID Number If you change the ID number make sure to press the Initialize SCSI soft key Do not set the same SCSI ID number for the external SCSI device and the internal hard disk of the DL750 DL750P The SCSI ID numbers of external SCSI devices are automatically detected when the DL750 DL750P is turned ON...

Страница 130: ...A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the File Item soft key The File Item setup menu appears 3 Press the Waveform soft key Selecting the Data Type 4 Press the Data Type soft key The data type selection menu appears 5 Press the Binary ASCII or Float soft key to select the data type Note Binary files can be saved and loaded ASCII and Float files can only be...

Страница 131: ... and Saving Decimating the Data and Saving Decimating the Data and Saving When Data Type Is Set to ASCII 12 Press the Save Interval soft key Turn the jog shuttle to set the save interval from OFF Per5 to Per5000 Compressing the Data and Saving When Data Type Is Set to Binary 12 Press the P P Comp soft key to select ON compress and save or OFF do not compress and save If P P Comp is turned ON when ...

Страница 132: ...Directory Perform this operation when directories are present on the medium 16 Turn the jog shuttle to select the save destination directory indicated by 17 Press SELECT to confirm the directory The selected medium directory is displayed in Path located above and to the left of the File List window Select to move to the parent directory Note If History is set to All MATH channels are not saved If ...

Страница 133: ...HD or USB storage device is displayed at the upper left corner of the screen Note The voice memo function section 7 9 can be used to record voice memos while waveforms are being acquired when in roll mode display The voice memo is saved along with the waveform data Voice memo can be attached only to waveform data in binary format wvf extension and realtime recorded waveform data wdf extension In a...

Страница 134: ...ect the file Executing the Load Operation 9 Press the Load Exec soft key A dialog box appears showing the module information of the selected waveform data and the current module information of the DL750 DL750P 10 Press the Load Exec soft key again The selected file is read from the directory indicated in Path At the same time the Load Exec soft key changes to an Abort soft key Note Waveform data o...

Страница 135: ... waveform data is loaded You cannot load only the sub waveform data file Do not delete only the main waveform data file or only the sub waveform data file ASCII The units of the sampled data in the acquisition memory are converted per the specified range and saved in ASCII format The data can be used to analyze the waveform on a PC The file cannot be loaded to the DL750 DL750P The extension is CSV...

Страница 136: ...set History to One You can also save only the results obtained by searching the history memory data For a description of searching the history memory data see section 11 2 For a description of snapshot waveforms see section 13 9 Selecting the Range of the Waveform to Be Saved Select the range region of the waveform from the following list of choices Only the data that has been saved by selecting B...

Страница 137: ...a common name up to four characters specified by File Name that is placed before the number Date Files are automatically named using 8 characters base 36 consisting of 0 to 9 and A to Z based on the date and time The file name specified by File Name is void Year Month Day Hour Time in unit of 100 ms 0 ms 0000 100 ms 0001 59 min 50 s 900 ms 0RRZ 0 hour 0 9 hour 9 10 hour A 23 hour N 1 day 1 10 day ...

Страница 138: ... be used when using the FTP server function network printer function or the Web server function Waveform wvf and header hdr files are saved as file pairs If you specify for the files to be displayed Filter on the File List and manipulate individual files Delete Rename or Copy the file can no longer be loaded Files that do not have an archive attribute are not displayed in the File List window Do n...

Страница 139: ...X Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the File Item soft key The File Item setup menu appears 3 Press the Setup soft key Selecting Save Destination Medium 4 Press the Save soft key The save setup menu appears 5 Press the File List soft key The File List window appears 6 Turn the jog shutt...

Страница 140: ...ress the Save Exec soft key The data is saved to the directory indicated by Path At the same time the Save Exec soft key changes to an Abort soft key While the data is being saved an icon corresponding the save destination medium FD Zip disk PC card external SCSI device internal HD or USB storage device is displayed at the upper left corner of the screen Aborting the Save Operation 18 Press the Ab...

Страница 141: ... 9 in Saving the Setup Data Selecting the File to Be Loaded 6 Turn the jog shuttle to select the file Executing the Load Operation 7 Press the Load Exec soft key A dialog box appears showing the module information of the selected setup data and the current module information of the DL750 DL750P 8 Press the Load Exec soft key again The selected file is read from the directory indicated in Path At t...

Страница 142: ...ecify the file name using up to 16 characters The characters that can be used are 0 9 A Z _ and Auto Naming Select from the following three types OFF The name specified by File Name is attached Numbering Files are automatically named with four digit numbers from 0000 to 4999 You can specify a common name up to four characters specified by File Name that is placed before the number Date Files are a...

Страница 143: ...ng and Loading is not possible while data acquisition is in progress If you change the extension of the file such as on a PC the file can no longer be loaded Up to 36 characters can be displayed in Path File names are not case sensitive Comments are case sensitive In addition the following five file names cannot be used due to limitations of MS DOS AUX CON PRN NUL CLOCK COM1 to COM9 and LPT1 to LP...

Страница 144: ...AL HORIZONTAL CAL X Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the File Item soft key The File Item setup menu appears 3 Press the Snap soft key Selecting Save Destination Medium 4 Press the Save soft key The save setup menu appears 5 Press the File List soft key The File List window appears 6 T...

Страница 145: ...ec soft key The data is saved to the directory indicated by Path At the same time the Save Exec soft key changes to an Abort soft key Aborting the Save Operation 18 Press the Abort soft key The save operation is aborted At the same time the Abort soft key changes to a Save Exec soft key While the data is being saved an icon corresponding the save destination medium FD Zip disk PC card external SCS...

Страница 146: ...g the Load Source Medium Directory 4 Press the Load soft key The load setup menu and File List window appear 5 Select the load source directory according to steps 4 to 9 in Saving Snapshot Waveforms Selecting the File to Be Loaded 6 Turn the jog shuttle to select the file Executing the Load Operation 7 Press the Load Exec soft key The selected file is read from the directory indicated in Path At t...

Страница 147: ...d in the File List window and properties are the same as those for saving loading normal waveform data For details see section 13 7 Saving Loading the Waveform Data Clearing the Waveform The loaded snapshot waveform is cleared when CLEAR TRACE or initialization is performed Note An error occurs if a key other than the Abort key is pressed while saving or loading a file This function cannot be used...

Страница 148: ... TRIG D VERTICAL HORIZONTAL CAL X Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the File Item soft key The File Item setup menu appears 3 Press the Measure soft key Selecting Save Destination Medium 4 Press the Save soft key The save setup menu appears 5 Press the File List soft key The File List w...

Страница 149: ...me time the Save Exec soft key changes to an Abort soft key While the data is being saved an icon corresponding the save destination medium FD Zip disk PC card external SCSI device internal HD or USB storage device is displayed at the upper left corner of the screen Aborting the Save Operation 18 Press the Abort soft key The save operation is aborted At the same time the Abort soft key changes to ...

Страница 150: ...y waveforms bytes Data Extension The extension is CSV The selection of the medium and directory file name comments auto naming function specification of the files to be displayed in the File List window and properties are the same as those for saving loading normal waveform data For details see section 13 7 Saving Loading the Waveform Data Note An error occurs if a key other than the Abort key is ...

Страница 151: ...t Setting the Color When Format Is PNG JPEG or BMP 4 Press the Color soft key to select ON ON Revers ON Gray or OFF Setting the Compression Format When Format Is BMP and Color Is Not OFF 5 Press the Compression soft key to select ON or OFF Setting a Comment 5 Press the Comment soft key 6 Enter the comment using up to 20 characters according to the procedure given in section 4 2 Selecting Save Dest...

Страница 152: ...g to the procedure given in section 4 2 Note If Auto Naming is set to Numbering the first four characters are valid If Auto Naming is set to Date the file name is invalid You can set up to 16 characters for the file name but only 15 characters are displayed on the setup menu When saving screen image data voice comment data can be saved along with the screen image data For details see section 13 19...

Страница 153: ...r ON GRAY Output the data using a tint of 16 gray levels OFF Output in black and white Setting the Compression Format When Format Is BMP and Color Is Not OFF When the output format is set to BMP the data can be output by compressing using RLE However data compression is not possible if the color is OFF Setting a Comment A comment of up to 20 characters can be added to the lower section of the scre...

Страница 154: ...0RRZ Year Month Day Hour 0 hour 0 9 hour 9 10 hour A 23 hour N 1 day 1 10 day A 31 day V 1 month 1 10 month A 11 month B 12 month C 2000 year 0 2010 year A 2035 year Z Note Up to 16 characters can be entered for the common name Characters exceeding 16 characters are void Notes When Saving Screen Image Data The maximum number of files that can be saved when auto naming is enabled is 5000 If the tot...

Страница 155: ... the soft key corresponding to the save format of the screen image data of which you wish to display the thumbnails from PNG to PostScript Displaying the Thumbnails of the Specified Screen Image Data 4 Press the File List soft key The File List window appears 5 Turn the jog shuttle to select the screen image data file in the File List window 6 Press SELECT The thumbnail of the selected screen imag...

Страница 156: ...ied in step 3 are displayed 9 thumbnails 3 3 in the waveform display area 7 If there are more than 9 thumbnails you can scroll the screen using the jog shuttle To scroll the files upward turn the jog shuttle counter clockwise To scroll the files downward turn the jog shuttle clockwise The files scroll three files at a time 8 To clear the list of thumbnails press ESC Note If you set Path FD floppy ...

Страница 157: ... 6 Press the Utility soft key The File List window appears 7 Turn the jog shuttle to select the screen image data file file with png jpg bmp and ps extensions on the File List window 8 Press SELECT The thumbnail of the selected screen image data file is displayed at the lower right section of the File List window When screen image data that has voice comment data is selected the voice comment is p...

Страница 158: ...right and top to bottom Scrolling the Thumbnail Screen If the number of thumbnails exceeds the maximum number of thumbnails that can be displayed 9 the thumbnail screen can be scrolled one row three thumbnails at a time To scroll the files upward turn the jog shuttle counter clockwise To scroll the files downward turn the jog shuttle clockwise Thumbnails on the File List When you select a screen i...

Страница 159: ...int destination selection menu appears Net Print appears only when the Ethernet interface option is installed 3 Press the PDF soft key When displaying T Y waveforms proceed to step 4 When displaying X Y waveforms proceed to step 8 Selecting the Section to Be Output to the PDF File Only When Displaying the T Y Waveform 4 Press the Time Range1 Time Range2 soft key 5 Use the jog shuttle and SELECT to...

Страница 160: ...e Flexible Zone Only When Displaying the T Y Waveform 11 Use the jog shuttle and SELECT to select Setup in Flexible Zone 12 Use the jog shuttle and SELECT to set Mode to OFF or ON 13 Use the jog shuttle and SELECT to set Upper Lower of the waveform to be recorded Setting the Graticule Setting the Grid 14 Use the jog shuttle and SELECT to set Type to OFF or Setting Dark Light 15 Use the jog shuttle...

Страница 161: ...t the type of annotation to be printed in the right column of Type to CH Information CH Message or CH Data If CH Message is selected proceed to step 22 If CH Information or CH Data is selected proceed to step 23 22 Use the jog shuttle and SELECT to select Setup Then enter the message you wish to print for the channel using up to 80 characters according to the procedure in section 4 2 Setting Comme...

Страница 162: ...e of the PDF file using up to 30 characters and the keyword using up to 90 characters according to the procedure given in section 4 2 Setting the Color 29 Use the jog shuttle and SELECT to set Color to OFF or ON Enabling Disabling Compression 30 Use the jog shuttle and SELECT to set Compression to ON or OFF Setting Auto Naming 31 Use the jog shuttle and SELECT to select Auto Naming from OFF Number...

Страница 163: ...ne and Graticule Scale The items other than graticule can be specified only when displaying T Y waveforms The format extra area flexible zone and graticule scale settings are the same as the settings when performing fine print or zoom print on the built in printer For details see page 12 10 Details Time Print Gauge Print Can be specified only when displaying T Y waveforms The time print and gauge ...

Страница 164: ...Landscape 1 to 25 1 to 20 A5 Portrait 1 to 10 1 to 10 A5 Landscape 1 to 20 1 to 15 Document Information Title Author Sub Title and KeyWord As necessary enter the title author sub title and keyword of the PDF file to be created Color The PDF file is created in color if ON is selected and monochrome if OFF is selected Compression Select whether to compress the file If ON is selected the file is comp...

Страница 165: ...e File name Scale value of the vertical scale Scale value of the vertical scale V div Value div Annotation CH information Page Scale value of the time axis Scale value of the time axis Scale value of the Y axis Sample rate Date Time File name Scale value of the X axis Scale value of the X axis 13 13 Creating PDF files of the printed image DL750P only ...

Страница 166: ...LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the File Item soft key The File Item setup menu appears 3 Press the Waveform soft key Selecting the Data Type 4 Press the Data Type soft key The data type selection menu appears 5 Press the Real Time soft key Selecting the Load Source Medium Directory 6 Press the Load soft key The load setup menu and File List wi...

Страница 167: ...e Abort soft key changes to a Load Exec soft key Specifying the Files to Be Displayed in the File List Window and Displaying Properties 12 Carry out steps 27 to 29 in Saving the Waveform Data in section 13 7 Note Files with WDF extension in the RealTime area and User area of the internal hard disk optional can be loaded Converting the Realtime Recorded Waveform Data to Binary ASCII or Float Format...

Страница 168: ... number of channels 1 1 05 to 1 15 bytes RealTime Drive The WDF data that is created by the realtime recording is saved to the RealTime drive The RealTime drive appears only when Data Type is set to Real Time If you wish to manage the files on the RealTime drive set Data Type to Real Time You can set the size of the RealTime drive in the range of 30 to 70 of the entire capacity of the internal har...

Страница 169: ...1 CH 12 CH 13 CH 14 CH 15 CH 16 DELAY MANUAL TRIG V DIV TIME DIV TRIGGER TRIG D VERTICAL HORIZONTAL CAL X Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the Utility soft key The Utility setup menu and the File List window appear Selecting Media and Directories 3 Select the medium and directory accor...

Страница 170: ...he left of every file in the directory containing the selected file or directory to indicate that they will be deleted At the same time the All Set soft key changes to an All Reset soft key 12 Press the All Reset soft key Asterisks are removed from the left of every file in the directory containing the selected file or directory to indicate that they will not be deleted At the same time the All Re...

Страница 171: ... the file Selecting the Files to Be Deleted You can delete all files that have an asterisk to the left of the file name There are two methods in selecting the files to be deleted Selecting the Files One at a Time Set Reset Place an asterisk to the left of the file names one at a time using the Set Reset soft key Selecting All the Files at Once All Set Places an asterisk to the left of all the file...

Страница 172: ...s after the error occurrence are not deleted You cannot change a directory attribute This function cannot be used when using the FTP server function network printer function or the Web server function The screen image data and thumbnail data are saved in pairs of files If you specify for the files to be displayed Filter on the File List and manipulate individual files Delete Rename or Copy the thu...

Страница 173: ...Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the Utility soft key The Utility setup menu and the File List window appear 3 Press the Function soft key The file function selection menu is displayed 4 Press the Copy soft key Selecting Media and Directories 5 Select the medium and directory according...

Страница 174: ...ng the selected file or directory to indicate that they will not be copied At the same time the All Reset soft key changes to an All Set soft key Selecting the Copy Destination 11 Press the Dest Dir soft key The copy execution menu and the copy destination File List window appears Selecting Copy Destination Medium and Directory 12 Select the copy destination medium and directory according to steps...

Страница 175: ...te the file was saved the attribute the comment etc Note Files cannot be copied while the data acquisition is in progress If an error occurs while copying multiple files the files after the error occurrence are not copied You cannot change a directory attribute You cannot copy files if files with the same file name exist at the copy destination You cannot copy the same files to another directory a...

Страница 176: ...DSP 4 EXP GO NO GO ACTION FILE SHIFT 1 Press FILE 2 Press the Utility soft key The Utility setup menu and the File List window appear 3 Press the Function soft key The file function selection menu is displayed 4 Press the Rename soft key Selecting Media and Directories 5 Select the medium and directory according to steps 4 to 9 in section 13 8 Saving Loading the Setup Data Changing the File Attrib...

Страница 177: ... File List window appear 3 Press the Function soft key The file function selection menu is displayed 4 Press the Make Dir soft key Selecting Media and Directories 5 Select the medium and directory according to steps 4 to 9 in section 13 8 Saving Loading the Setup Data Creating Directories 6 Turn the jog shuttle to select a medium or directory 7 Press the Dir Name soft key A keyboard appears 8 Ente...

Страница 178: ...sible R Read only Cannot write to the file or delete the file Changing the Directory File Name of the Storage Medium Rename Number of characters and types that can be used Item Number of Characters Characters That Can Be Used Directory name 1 to 16 characters 0 to 9 A to Z _ File name 1 to 16 characters 0 to 9 A to Z _ However a directory name that starts with ND ND000 for example is not allowed C...

Страница 179: ... file cannot be renamed If a directory with the same name already exists in the same directory the directory cannot be created This function cannot be used when using the FTP server function network printer function or the Web server function The screen image data and thumbnail data are saved in pairs of files If you specify for the files to be displayed Filter on the File List and manipulate indi...

Страница 180: ...n changing the ID see section 13 6 Changing the ID Number of the Internal Hard Disk Drive Set the ID number of the internal hard disk drive so that it does not overlap with the IDs of other SCSI devices For the procedure in changing the ID see section 13 6 CAUTION Make sure to follow the procedures exactly as written in Connecting the instrument to the PC described below Otherwise drives of other ...

Страница 181: ...erate properly Other drives are used to save other types of data such as waveforms that can be recalled later The waveforms that can be used on the PC are saved on this drive Newly Created File During Connection If a file is created with the DL750 DL750P while it is connected to the PC the new file is not recognized by the PC If the PC is running Windows 98 98 SE Me the following procedures allow ...

Страница 182: ... Before connection C HDD D HDD After connection C HDD D HDD E DL750 DL750P Actually this may vary depending on how the hard disk is partitioned and the type of interface IDE SCSI etc and drive Note The internal hard disk of the DL750 DL750P has a built in terminator When the DL750 DL750P is connected to a PC it is recommended that the DL750 DL750P be connected to the end of the SCSI chain Note tha...

Страница 183: ...OR RESET SELECT CH ALL CH MODE POSITION SIMPLE ENHANCED ACQ START STOP SETUP DISPLAY ZOOM DUAL CAPTURE HISTORY MATH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 DELAY MANUAL TRIG V DIV TIME DIV TRIGGER TRIG D VERTICAL HORIZONTAL CAL X Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT ...

Страница 184: ... for saving the screen image data are the same as those in section 13 11 For details see section 13 11 Playing of the Voice Comment The saved voice comment can be played from the File List window of the IMAGE and FILE menus 6 Open the File List window according to steps 1 to 4 on page 13 42 or steps 1 to 6 on page 13 44 7 Turn the jog shuttle to select the screen image data file in the File List w...

Страница 185: ...To erase only the voice comment of the saved screen image data erase the relevant voice comment data on the File List window of the FILE menu For the procedure of displaying the File List window see steps 1 to 7 on page 13 44 For the procedure of erasing the data see section 13 15 Playing a Voice Comment Confirmation before Saving the Data Play You can play the recorded voice comment to check the ...

Страница 186: ...ger Note By using the trigger output function the operation of two DL750 DL750Ps can be synchronized TRIG OUT No 1 TRIG IN No 2 DL750 DL750P FILE SHIFT HELP MISC NUM KEY PROTECT VOICE MEMO IMAGE SAVE PRINT ESC MEASURE CURSOR RESET SELECT CH ALL CH MODE POSITION SIMPLE ENHANCED ACQ START STOP SETUP DISPLAY ZOOM DUAL CAPTURE HISTORY MATH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 CH 9 CH 10 CH 11 CH 12 CH...

Страница 187: ...d rises after completing acquisition Output delay time Within 1 µs 1 sample period Output hold time 200 ns or more Trigger Output Circuit Diagram and Timing Chart LCX14 or equivalent EXT TRIG OUT EXT CLK IN 100 Ω 5 V HC245 or equivalent 4 7 kΩ 100 pF Trigger occurrence time of trigger position Trigger Output Internal trigger Output hold time Output delay time Low Level High Level Hold Time H L Tri...

Страница 188: ...Terminal TRIG OUT EXT CLK IN Use this terminal if you wish to operate the DL750 DL750P using an external clock signal This terminal is shared with the trigger output terminal TRIG OUT Specifications Connector type RCA jack Input Level TTL 0 to 5 V Valid edge Rising edge Minimum pulse width 400 ns or more for high and low External clock frequency range 1 MHz maximum External Clock Input Circuit Dia...

Страница 189: ...put to a monitor through the video signal output Connectable monitors are multi sync monitors capable of displaying SVGA Specifications Connector type 15 pin D SUB Output type Analog RGB output Output resolution SVGA output 800 600 dots 60 Hz Vsync 6 11 1 5 15 10 D Sub 15 pin receptacle Pin No Signal Name Specifications 1 Red 0 7 VP P 2 Green 0 7 VP P 3 Blue 0 7 VP P 4 5 6 GND 7 GND 8 GND 9 10 GND...

Страница 190: ...Turn OFF the DL750 DL750P and the monitor 2 Connect the DL750 DL750P and the monitor using an analog RGB cable 3 Turn ON the DL750 DL750P and the monitor 4 Press the MISC soft key 5 Press the Next 1 2 soft key 6 Press the Others soft key 7 Press the Video Out soft key to select ON The screen of the DL750 DL750P is displayed on the monitor Select OFF to stop the display on the monitor ...

Страница 191: ...GO menu Specifications Modular jack RJ 11 Use the optional accessory 366973 sold separately for the cable 6 1 1 Pin No Signal Name 2 3 4 5 6 NC no connection START IN NC no connection GO NO GO NC no connection Connector on the DL Start on the low edge Stop on the high edge GND SPEAKER Input level TTL 0 to 5 V External Start Stop Input Circuit Diagram 5 V 120 Ω LCX14 4 7 kΩ 100 pF 2 Pin No High Low...

Страница 192: ... Digital Filters Gauss Sharp IIR Butterworth and Moving Average See section 15 3 Using Filters DSP Channels Differentiation and Integration See section 15 4 Performing Differentiation and Integration DSP Channels Addition Subtraction Multiplication and Division and with Coefficients between Channels See section 15 5 Performing Addition Subtraction Multiplication and Division with Coefficients DSP ...

Страница 193: ...knob 1 2 5 steps 10 00E 21 Value Div to 500 0E 18 Value Div Variable Setting When variable is set to OFF zooming in or out by setting the zoom rate Zoom rate The following zoom rates are available 0 1 0 111 0 125 0 143 0 167 0 2 0 25 0 33 0 4 0 5 0 556 0 625 0 667 0 714 0 8 0 833 1 1 11 1 25 1 33 1 43 1 67 2 2 22 2 5 3 33 4 5 6 67 8 10 12 5 16 7 20 25 40 50 and 100 Zoom position The waveform is zo...

Страница 194: ...le and SELECT to set Operation to S1 S2 S1 S2 S1 S2 or S1 S2 Selecting the Channel on Which to Perform Computation 4 Use the jog shuttle and SELECT to select Source1 5 Likewise select Source2 Setting Value Div 6 Turn the V DIV knob to set the Value Div value You can also set Value Div by pressing the Value Div soft key and turning the jog shuttle Note There are 123 selectable range 10 00E 21 Value...

Страница 195: ...Vertically According to the Upper and Lower Limits of the Display Range 8 Press the Variable soft key to select ON 9 Press the Upper Lower soft key to set the jog shuttle control to Upper 10 Turn the jog shuttle to set the upper limit 11 Press the Upper Lower soft key to set the jog shuttle control to Lower 12 Turn the jog shuttle to set the lower limit Proceed to step 13 Setting the Waveform Labe...

Страница 196: ...e Div soft key and turning the jog shuttle Automatically Selecting the Optimum Value Div Setting When you press the Optimize Value Div soft key the optimum range is automatically selected from the 123 Value Div settings and the waveform is displayed using the selected setting Zooming in on the Waveform Zooming in or out Vertically by Setting the Zoom Rate For details see section 5 8 Zooming Vertic...

Страница 197: ...etup dialog box opens 3 Use the jog shuttle and SELECT to set Operation to Filt S1 Selecting the Channel on Which to Perform Computation 4 Use the jog shuttle and SELECT to select Source1 Setting the Filter 5 Use the jog shuttle and SELECT to set the Filter Type to Sharp Gauss IIR or Mean When Sharp or IIR Is Selected 6 Press the Filter Band soft key to select Low Pass High Pass or Band Pass 7 Use...

Страница 198: ...mize Value Div soft key appears only when Variable is OFF When using a filter the range is set to the same range as the computed channel Zooming in on the Waveform The procedure of Zooming in or out Vertically by Setting the Zoom Rate and Zooming Expanding Vertically According to the Upper and Lower Limits of the Display Range is the same as the procedure described in section 15 2 Performing Addit...

Страница 199: ...ion slope is between SHARP and GAUSS LPF IIR Butterworth Not linear phase and group delay not constant HPF No ripple in either passband or stopband BPF Close to the characteristics of an analog filter Cutoff frequency can be set lower than SHARP GAUSS 1 LPF HPF and BPF denote low pass filter high pass filter and bandpass filter respectively The cutoff frequency center frequency and pass band can b...

Страница 200: ... the Display Range For details see section 5 9 Zooming Vertically According to the Upper and Lower Limits of the Display Range and Notes Concerning Display in section 15 1 Setting the Unit Unit can be set arbitrarily using up to four characters The specified characters are applied to the scale values Notes When Using Filters The following limitations exist depending on the acquisition mode setting...

Страница 201: ...og box opens 3 Use the jog shuttle and SELECT to set Operation to Diff S1 differentiation or Integ S1 integration Selecting the Channel on Which to Perform Computation 4 Use the jog shuttle and SELECT to select Source1 Setting Differentiation and Integration When Diff S1 Is Selected 5 Use the jog shuttle and SELECT to set Filter to ON or OFF 6 Use the jog shuttle and SELECT to set the CutOff in th...

Страница 202: ...erring to the range of the computed channel It does not select the optimum Value Div setting for the output waveform after computation For easy viewing of the waveform after computation select the approximate range using Optimize Value Div and then use the V DIV knob or Value Div soft key to adjust to the optimum range Zooming in on the Waveform The procedure of Zooming in or out Vertically by Set...

Страница 203: ...edge at the zero crossing point Zero Cross to Negative Reset when the target channel produces a negative edge at the zero crossing point Setting Value Div Like V div Value Div is set using 1 2 5 steps The selectable range is 10 00E 21 Value Div to 500 0E 18 Value Div with 123 settings Turn the V DIV knob to set the Value Div value You can also set Value Div by pressing the Value Div soft key and t...

Страница 204: ...For a description of turning ON OFF the DSP see section 5 1 For a description of setting the vertical position see section 5 4 For a description of zooming vertically by setting the zoom rate see section 5 8 For a description of setting waveform labels see section 8 10 Setting the Computation Definition 2 Press the Setup soft key A setup dialog box opens 3 Use the jog shuttle and SELECT to set Ope...

Страница 205: ...r the output waveform after computation For easy viewing of the waveform after computation select the approximate range using Optimize Value Div and then use the V DIV knob or Value Div soft key to adjust to the optimum range Zooming in on the Waveform The procedure of Zooming in or out Vertically by Setting the Zoom Rate and Zooming Expanding Vertically According to the Upper and Lower Limits of ...

Страница 206: ...21 Value Div to 500 0E 18 Value Div with 123 settings Turn the V DIV knob to set the Value Div value You can also set Value Div by pressing the Value Div soft key and turning the jog shuttle Automatically Selecting the Optimum Value Div Setting When you press the Optimize Value Div soft key the optimum range is automatically selected from the 123 Value Div settings and the waveform is displayed us...

Страница 207: ...ft key A setup dialog box opens 3 Use the jog shuttle and SELECT to set Operation to KnockFlt S1 Selecting the Channel on Which to Perform Computation 4 Use the jog shuttle and SELECT to select Source1 Setting the Filter 5 Use the jog shuttle and SELECT to set the Filter Type to Sharp IIR or Diff When Sharp or IIR Is Selected 6 Use the jog shuttle and SELECT to set the Filter Band to High Pass or ...

Страница 208: ...e Optimize Value Div soft key appears only when Variable is OFF When using the knocking filter the range is set to the same range as the computed channel Zooming in on the Waveform The procedure of Zooming in or out Vertically by Setting the Zoom Rate and Zooming Expanding Vertically According to the Upper and Lower Limits of the Display Range is the same as the procedure described in section 15 2...

Страница 209: ...ber smaller than itself can be specified Digital Filter That Can Be Used in the Knocking Filter The following three digital filters can be specified For details see appendix 6 Sharp IIR Butterworth and Diff differentiation Filter Format Characteristics Filter Type Computation Type SHARP Attenuation slope of the frequency response is HPF FIR steep 40 dB per octave Linear phase and constant group de...

Страница 210: ...Level Set the reference level for noise elimination The selectable range and resolution of the elimination level are the same as those of the trigger level See section 6 5 Setting Value Div Like V div Value Div is set using 1 2 5 steps The selectable range is 10 00E 21 Value Div to 500 0E 18 Value Div with 123 settings Turn the V DIV knob to set the Value Div value You can also set Value Div by pr...

Страница 211: ...e sampling frequency For example if the sampling frequency is 100 kHz and you set the cutoff frequency to 10 the cutoff frequency is set to 10 kHz If the sampling frequency exceeds 100 kHz the sampling frequency of DSP channels is decimated to 100 kHz Therefore if the sampling frequency exceeds 100 kHz the specified frequency is a percentage of 100 kHz regardless of the actual sampling frequency W...

Страница 212: ...ps max Communication protocol TCP IP Supported services FTP server FTP client network drive LPR client network printer SMTP client mail transmission DHCP DNS and Web server Connector type RJ 45 connector ETHERNET 100BASE TX port RJ 45 modular jack 100BASE TX LINK ACT ACT LED Blinks when packet transmission is being carried out normally LINK LED Illuminates when the link between the port on the DL7...

Страница 213: ...d the PC or workstation 2 Connect one end of the UTP or STP cable to the ETHERNET 100BASE TX terminal on the left side panel 3 Connect the other end of the UTP or STP cable to a hub or router 4 Likewise connect the PC or workstation to a hub or router 5 Turn ON the DL750 DL750P Hub or router that supports 100BASE TX UTP cable or STP cable Straight cable DL750 DL750P FILE SHIFT HELP MISC NUM KEY PR...

Страница 214: ...ON or OFF If you DHCP to OFF proceed to step 5 If the DHCP is set to ON you do not have to set the IP address subnet mask and default gateway To set up the DNS proceed to step 11 If you do not wish to set up the DNS check the network cable connection and restart the DL750 DL750P The IP address subnet mask and default gateway are automatically configured Setting the IP Address Set the IP address if...

Страница 215: ...lect Domain Name 10 Enter the domain name according to the procedure given in section 4 2 Setting the DNS Server 11 Use the jog shuttle and SELECT to set DNS Server1 primary DNS server Enter using values in the range of 0 to 255 12 Likewise set the secondary DNS server in DNS Server2 Setting the Domain Suffix 13 Use the jog shuttle and SELECT to set Domain Suffix1 primary domain suffix 14 Likewise...

Страница 216: ...mputers on the network Consult your network administrator for the subnet mask value You may not need to set the value The setting is automatically configured in environments using DHCP Default Gateway Set the IP address of the gateway default gateway used to communicate with other networks The default setting is 0 0 0 0 The default gateway has control functions that handle protocol exchanges when ...

Страница 217: ...ned ON with the DHCP function enabled without an Ethernet cable connected communications and file functions may not operate properly In this case turn DHCP OFF and power cycle the DL750 DL750P Configuring the TCP IP Settings of the PC Communication parameters such as the IP address must also be specified on the PC side Communication parameters are specified for each Ethernet NIC that is installed ...

Страница 218: ...16 7 IM 701210 06E Ethernet Interface Optional 16 4 Set the parameters such as the IP address according to the table on the previous page and click OK 16 2 Setting up the TCP IP ...

Страница 219: ...ive Setup soft key The Net Drive setup menu appears Setting the FTP Server 4 Use the jog shuttle and SELECT to select FTP Server 5 Enter the IP address of the FTP server according to the procedure given in section 4 2 When using DNS section 16 2 you can specify the address by name Setting the Login Name and Password 6 Use the jog shuttle and SELECT to select Login Name 7 Enter the login name using...

Страница 220: ...en press SELECT to close the connection The displayed at the upper right corner of the screen disappears Saving Loading the Screen Image Waveform and Setup Data Saving Loading the screen image data 12 Press SHIFT IMAGE SAVE 13 Press the File List soft key The File List window appears 14 Use the jog shuttle to select Network in the File List window 15 The succeeding procedure is the same as the pro...

Страница 221: ...indow 15 The succeeding procedure is the same as the procedure described in section 13 8 Saving Loading the Setup Data and section 13 7 Saving Loading the Waveform Data In addition waveform data with a voice memo attached can be saved loaded For details see section 7 9 Using the Voice Memo Function 16 3 Saving Loading Screen Images Waveforms and Setup Data to a Network Drive FTP Client Function ...

Страница 222: ...If you are disconnected by the server when using the FTP client you will be automatically reconnected if you perform a file operation This also hold true if the network drive is selected for Save to File when using an action trigger or GO NO GO Explanation You can save the screen image data waveform data and setup data to network drives via the Ethernet network in the same fashion as with the flop...

Страница 223: ... the LPR Server 4 Use the jog shuttle and SELECT to select LPR Server 5 Enter the IP address of the printer server according to the procedure given in section 4 2 If you are using DNS you can specify the printer server by name Setting the Printer Name 6 Use the jog shuttle and SELECT to select LPR Name 7 Enter the printer name according to the procedure given in section 4 2 Note For keyboard soft ...

Страница 224: ...tting the Network Printer Net Print Setup LPR Server Specify the IP address of the network printer server On networks supporting DNS you can specify the host and domain by name instead of the IP address Printer Name LPR Name Specify the name of the printer on which screen image data will be printed Selecting the Output Format The following six printer formats are supported ESC P ESC P2 LIPS3 PCL5 ...

Страница 225: ...tting the Recipient Mail Address 6 Use the jog shuttle and SELECT to select Mail Address 7 Enter the recipient mail address using up to 40 characters according to the procedure given in section 4 2 Setting a Comment 8 Use the jog shuttle and SELECT to select Comment 9 As necessary enter the comment using up to 30 characters according to the procedure given in section 4 2 Setting the Time When the ...

Страница 226: ... 9 CH 10 CH 11 CH 12 CH 13 CH 14 CH 15 CH 16 DELAY MANUAL TRIG V DIV TIME DIV TRIGGER TRIG D VERTICAL HORIZONTAL CAL X Y SEARCH 7 DSP 1 8 9 DSP 2 6 5 4 1 0 2 3 ENTER m DSP 6 DSP 5 LOGIC A LOGIC B EVENT DSP 3 DSP 4 EXP GO NO GO ACTION FILE SHIFT FILE SHIFT HELP MISC NUM KEY 1 Set items according to steps 1 to 9 in Sending Periodic E mail Messages You do not have to set MailBaseTime and Interval for...

Страница 227: ...GO NO GO operation When a specified condition occurs a mail is sent to the specified address While mail transmission is in progress is indicated at the upper left corner of the screen Note The mail recipient is the address specified in Mail Address of Network Mail Setup in the MISC menu The sender From address of the e mail messages sent by the DL750 DL750P is the same as the specified recipient a...

Страница 228: ...hing Image Data Attached Image File Version 4 01 or Later The screen image shown at the time of mail transmission can be attached to the mail The data format of the screen image data is the format specified in section 13 11 Saving Screen Image Data The file name differs between periodic mail and action mail File name of periodic mail DL_image png File name of action mail DL_nnnn png where nnnn is ...

Страница 229: ...orm parameters see section 11 8 is executed The maximum number of measurement results of waveform parameters that are sent is the same as the maximum number 24 of measurement results displayed on the DL750 DL750P Sample Periodic Mail Comment aaaaaa ACQ Status Stopped 162 GO NOGO Status Success 140 Fail 21 Max C1 4 16667V SDv C2 697 941mV Freq C3 500 0000kHz Wd C4 1 00us ErrNo 004 Exit from GO NO G...

Страница 230: ...Information of GO NO GO Only when GO NO GO determination is executed see sections 11 8 and 11 9 Results of Waveform Parameter Measurement Only when automated measurement of waveform parameters see section 11 6 or GO NO GO determination using waveform parameters see section 11 8 is executed Fail Cause Only when GO NO GO determination is executed see sections 11 8 and 11 9 Sample Action Mail Comment...

Страница 231: ... the procedure given in section 4 2 Specify anonymous if you wish to allow access to all users To restrict access enter the user name using up to 15 characters Setting the Password 6 Use the jog shuttle and SELECT to select Password 7 Enter the password using up to 15 characters according to the procedure given in section 4 2 If you select the ENT key on the soft keyboard or press the ENT soft key...

Страница 232: ...FF The DL750 DL750P supports two clients but file operations cannot be performed simultaneously When the DL750 DL750P is being accessed from a PC or workstation logged in is displayed in the lower right part of the screen This function cannot be used when using the FTP client function network printer function or the Web server function or when performing file operations To use this function config...

Страница 233: ...yboard Password Enter the password using up to 15 characters The characters that can be used are all the ASCII characters on the keyboard Time Out The connection to the network is automatically closed if there is no access to the DL750 DL750P for the specified time Note It is recommended that the timeout be set to 600 s when using the FTP server function through a dedicated FTP client When using t...

Страница 234: ...ion See page 16 47 Overview of the Web Server Function FTP Server Function On the Web Browser View the list of files stored on the storage media of the DL750 DL750P internal hard disk or built in storage medium and transfer files to the PC Data Capture The following operations can be carried out Change the display format of the DL750 DL750P and display data that is acquired in the history memory D...

Страница 235: ...inting device supported by the OS indicated above Files Required for the Web Browser Of the Web server functions the following files are required when using the data capture measurement trend or command script function For the installation procedure on the PC see Installing Files Required for the Web Browser page 16 28 Msvbvm60 dll cmdlgjp dll comdlg32 ocx Combinations of OS and Application Softwa...

Страница 236: ... Web browser The Web server function contains software programs that have not been authenticated Therefore the following dialog box may appear In such case click Yes and install the software You cannot open multiple Internet Explorer windows on the same PC and use the same function of the Web server function simultaneously When using the storage function of the FTP server function on the Web brows...

Страница 237: ...munication means Setting up the TCP IP 5 Set the TCP IP on the PC and the DL750 DL750P For the procedure on the DL750 DL750P see section 16 2 Setting the User Account Used to Access the DL750 DL750P 6 Set the user account used to access the DL750 DL750P from the PC For the procedure see section 16 6 Note The User Account in the menu that appears after step 4 is the user account that is used to con...

Страница 238: ...mple 192 168 0 101 or the host name of the DL750 DL750P for example dl750 1 if a DNS server is available on the network Enter the IP address http 192 168 0 101 Enter the host name http dl750 1 4 Press the ENTER key on the PC keyboard A network password entry dialog box opens 5 Enter the user name and password Enter the user account see section 16 6 used to access the DL750 DL750P In the example be...

Страница 239: ...re already installed in the PC when using the Web server function for the first time step 7 is no required 7 When the data capture measurement trend or command script function of the Web server function is used for the first time three files Msvbvm60 dll cmdlgjp dll and comdlg32 ocx are automatically downloaded from the Microsoft Web site and installed in the PC At this point a dialog box for conf...

Страница 240: ...tioned three files starts Follow the instructions to install the files Checking the Web Browser Internet Explorer Security Settings Check the security settings on the Internet Explorer The settings indicated in the table on the next page are defaults If the settings on your browser do not match set them back to the settings in the table on the next page Otherwise the Web server function cannot be ...

Страница 241: ...ox opens 13 Set the security settings as shown in the following table Item Security Level Run ActiveX controls and plug ins Enable Script ActiveX controls marked safe for scripting Enable Download signed ActiveX controls Prompt 14 Click OK 16 7 Using the Web Server Function ...

Страница 242: ...h button on the Web browser A login dialog box opens Log in The storage media view window appears Web Server Window Storage Media View Window Internal hard disk Real Time Area used by realtime recording HD0 HD1 Storage area for waveform and setup data the number of displayed items varies depending on the number of partitions Built in storage media Depending on the product specifications one of the...

Страница 243: ...e FTP server function or realtime recording the Web server function cannot be used To use the FTP server on a Web browser a network user account on the DL750 DL750P must be configured For the procedure of setting user accounts see steps 1 to 8 in section 16 6 An authentication login dialog box may appear on the Web browser when the FTP icon on the Web server window is clicked In such case enter th...

Страница 244: ...ow Stop Click Stop to turn off the update indicator and stop the updating of the screen image Update The screen image is updated when you click Update Interval Set the display update interval to 10 s 30 s or 60 s Update indicator Selecting the Display Color of the Screen Image Color Select the display color from ON OFF Reverse and Gray For a description of the displayed information for each settin...

Страница 245: ...n the PC Capture Data Type Select the type of data to be saved from Waveform Binary Waveform ASCII Waveform Float Setup and Measure For details on the settings see the explanations in section 13 7 13 8 and 13 10 Capture Exec Using the dialog box that appears when you click Capture Exec set the save destination and file name and save the data Abort To abort the save operation while data is being sa...

Страница 246: ...he data save operation when there is no waveform data or waveform parameter an error is displayed on the DL750 DL750P screen and a 0 byte file is saved Controlling the DL750 DL750P Instrument Control You can use the PC to set the display format and the data save conditions of the DL750 DL750P The settings entered here apply to the display format and save conditions used to save the data on the pre...

Страница 247: ...waveforms to be saved from the following All all waveforms 1 to 16 channels 1 to 16 DSP1 to DSP6 optional Math 1 to Math 8 computed waveforms PodA to PodB logic waveforms and Event event waveform Selecting the Save Area Range Select the area in which the target waveform to be saved is displayed from the following Main Z1 and Z2 For the meanings of the selections see the explanation in section 13 7...

Страница 248: ...t would cause the screen image to change Clear the check box to not update automatically Note You cannot set the history data display when the DL750 DL750P is making measurements Setting the history data display when there is no history data results in error The timeout time on the PC when controlling the DL750 DL750P is 30 s Depending on the DL750 DL750P condition a timeout may occur preventing y...

Страница 249: ...ement values and trend Microsoft Excel 97 or later must be installed on the PC Set the time axis setting of the DL750 DL750P to 100 ms div or less faster This function cannot be used on time axis settings that exceed 100 ms div If the measured value of a waveform parameter is not a normal number Not A Number the cell displaying the measured value on Microsoft Excel is set to blank The retrieve int...

Страница 250: ...od PNUMBER Pulse BWIDTH1 Burst1 POVERSHOOT OShot BWIDTH2 Burst2 PTOPEAK P P DELAY Delay For a detail setting use Delay Setup on the DL750 DL750P DUTYCYCLE Duty PWIDTH Width FALL Fall RISE Rise FREQUENCY Freq RMS Rms HIGH High SDEVIATION Sdev LOW Low TY1INTEG Int1TY MAXIMUM Max TY2INTEG Int2TY Marker M1 2 M1 2 XY1INTEG Int1XY marker cursor for cursor measurements MIDDLE Mid XY2INTEG Int2XY Setting ...

Страница 251: ...Marker Position and Range that are set on the control Panel of the measurement trend window to match the newest setup conditions of the DL750 DL750P Starting Stopping the Trend Display of the Measured Values of the Waveform Parameters Start Click Start Stop The indicator illuminates in yellow and retrieval of the measured values of waveform parameters starts at the specified retrieve interval At t...

Страница 252: ...e Optional 16 Display Example of Measured Values Trend Graphs and Statistics Newest measured value Newest measured value Statistics Statistics Trend graph Graph2 Trend graph Graph1 List of measured values 16 7 Using the Web Server Function ...

Страница 253: ...ntrol Script icon on the Web server window The Control Script window used to send communication commands see the Communication Interface User s Manual IM701210 18E to the DL750 DL750P and display the responses from the DL750 DL750P appears Web Server Window Control Script Window Indicator Transmission command entry area Response display area 16 7 Using the Web Server Function ...

Страница 254: ... Setting the Transmission Interval Select the command transmission interval from the following 2 s 5 s 10 s 30 s and 60 s Starting Periodic Transmission Start Click Start Stop The indicator illuminates in yellow and the command transmission and response display start at the specified transmission interval Stopping Periodic Transmission Stop Click Start Stop while the periodic transmission is in pr...

Страница 255: ...Server Window Log Window Displaying the Log Selecting the Log Type Select Kind of Log From the list box select the item for displaying the log from the following Error log of errors that occurred on the DL750 DL750P Go Nogo log of GO NO GO determination For the setup procedure for the GO NO GO determination see sections 11 8 and 11 9 Action Trigger log of action on triggers For the setup procedure...

Страница 256: ...ows Partition number or LUN logical unit number Address number FD0 Floppy disk ZP0 Zip disk CA0 PC card SC5 SCSI device with the ID number set to 5 SC5 1 Partition 1 of a SCSI device whose ID number is 5 ND0 Network drive when the Ethernet interface option is installed US USB storage device When a SCSI device whose ID number is 5 is connected Note When the DL750 DL750P is printing operating files ...

Страница 257: ...Network see page 16 26 Click the Information icon on the Web server window The Information window that displays the DL750 DL750P model Model the maximum record length available Record Length the module configuration Module the storage media type Media the presence of options Option ROM version firmware version Soft Version and other information appears Web Server Window Information Window ...

Страница 258: ...view the Web page for the DL750 DL750P Web Server Window Web Page Example English Web Page Note To use the link function the PC must be connected to the Internet If the message language of the DL750 DL750P is set to English the English Web page is displayed if the message language is set to Japanese the Japanese Web page is displayed if the message language is set to Chinese the Chinese Web page i...

Страница 259: ...ey The Others setup menu appears Setting the Time Difference from GMT 4 Use the jog shuttle and SELECT to set the Time Hour of Time Difference From GMT in the range of 12 to 13 5 Likewise set the Minute of Time Difference From GMT in the range of 0 to 59 Note Minute can be specified only if Time Hour is set in the range of 11 to 12 Minute cannot be specified if Time Hour is set to 12 or 13 Setting...

Страница 260: ... site at the following URL http www worldtimeserver com Note The DL750 DL750P does not support daylight savings time To set the daylight savings time adjust the time difference from GMT Setting the SNTP When turning ON the power to the instrument the instrument s time is synchronized with that of the SNTP server connected to the network Note If a time difference from world standard time Greenwich ...

Страница 261: ...m in the overview screen this indicates that the Ethernet interface is installed The number indicated to the right is the MAC address MAC 000064_839_065 in the following screen Note Ether Yes is displayed only if the Ethernet interface option is installed If XXXXXX_XXX_XXX is displayed for the MAC address contact your nearest YOKOGAWA dealer Explanation You can check the presence of the Ethernet i...

Страница 262: ...uttle and SELECT to set SMTP Time Out Explanation Special settings related to the FTP client LPR and SMTP are entered Normally these parameters do not need to be specified Turning ON OFF FTP Passive Mode Turn this function ON when using the DL750 DL750P behind a firewall that requires the passive mode The default setting is OFF A firewall is furnished on a system that has security features It prev...

Страница 263: ...unction to enter TCP IP and user account settings then connect to the network Setting the PC 1 Open Entire Network Places 2 Choose Map Network Drive under Tools on the menu bar The Map Network Drive dialog box appears 3 Select the drive to assign in the drive selection area 4 Enter the instrument s IP address in the folder input area using the format http instrument s IP address dav 5 Click Finish...

Страница 264: ...files You cannot use the WebDAV function simultaneously with the Web server function Available Characters This function uses the Windows WebDAV client function and the instrument s WebDAV server function The characters that can be used with the WebDAV server function on this instrument are as follows 0 to 9 A to Z a to z _ Therefore please make note of the following Files and folders whose names c...

Страница 265: ...lanation Setting the Menu Language You can set the menu screen to English ENG Japanese JPN Chinese CHN or Korea Setting the Message Language A message appears when an error occurs or when you press the HELP key You can set the language of the messages to English ENG Japanese JPN Chinese CHN Korea KOR German GER French FRN or Italian ITL The messages codes are common in all languages For a descript...

Страница 266: ...form display area the scale values of the vertical axis and the trace labels waveform labels are shown using a large font Waveform display area Trace Label Waveform label Scale values of the vertical axis Waveform label Trace Label Waveform label Scale values of the vertical axis Waveform label Waveform display area The font size in the area enclosed by changes Scale values of the vertical axis Sc...

Страница 267: ...ILE SHIFT FILE SHIFT HELP MISC NUM KEY 1 Press MISC 2 Press the USB soft key 3 Press the USB Keyboard soft key to select ENG or JPN Explanation Setting the USB Keyboard Language The language of the USB keyboard that is used to enter items such as file names and comments see section 4 2 is specified The following keyboards conforming to USB Human Interface Devices HID Class Ver1 1 can be used ENG 1...

Страница 268: ...ttle and SELECT to select the item you wish to change the color The color selection menu appears 5 Use the jog shuttle and SELECT to select the color Note The items that you can change the color are as follows CH1 to CH16 DSP1 to DSP6 optional Math waveforms Logic A Logic B Event Background Capture Area sub waveform window of the dual capture function Menu Base Color menu screen In addition the se...

Страница 269: ...rm color Logic A Logic B Waveform color Event Waveform color Back Ground Background color of the waveform display area Capture Area Sub waveform window of the dual capture function Menu Base Color Menu Brightness Intensity You can set the brightness for the following items from 1 to 15 steps Wave Waveform Menu Back Ground Background Capture Area Sub waveform window of the dual capture function Sna...

Страница 270: ...5 Press the Auto OFF Time soft key 6 Turn the jog shuttle to set the time when the backlight will automatically turn OFF Setting the Backlight Brightness 7 Press the Brightness soft key 8 Turn the jog shuttle to set the backlight brightness Turning ON OFF the Backlight 9 Press the LCD OFF Exec soft key The backlight turns OFF Press any key to return to the measurement screen Explanation Turning ON...

Страница 271: ...The LED above the key illuminates and the keys are locked 2 To release the lock press PROTECT again Explanation This function locks the operation keys so that the current DL750 DL750P condition is not changed accidentally When keys are locked all keys other than the PROTECT key cannot be used Note When keys are locked operations using the USB mouse and USB keyboard are also disabled ...

Страница 272: ... values are not Insufficient warm up Warm up the DL750 for 30 minutes correct after turning on the power Not calibrated Perform a calibration 4 6 The probe s phase has not been Correct the phase properly 3 7 corrected The probe attenuation is not correct Set an appropriate value 5 6 An offset voltage is added Set the offset voltage to 0 V 5 10 Other causes Perform a calibration In addition 4 6 sel...

Страница 273: ... excitation voltage or the gauge factor was changed Carry out automatic balancing before use 66 Automatic balancing is running 67 Automatic balancing is complete 68 Test SUCCESS 69 Calibration is running 4 6 70 Calibration is complete 4 6 71 Completed action on trigger 6 17 73 Release the Preview mode 12 2 75 Aborted the search 11 2 to 11 4 76 Executed the search but no record was found that match...

Страница 274: ...the input signal 4 6 716 Realtime recording to the internal hard disk is valid when the sampling rate is slower than the values 7 7 shown below 1 2 CH 100 kS s 3CH 50 kS s 4 5CH 20 kS s 6 11CH 10 kS s 12 18CH 5 kS s 717 Too many channels for the current T div setting to realtime record 7 7 Decrease the number of channels by turning them OFF 718 Too many channels to realtime record at the current r...

Страница 275: ...ot set accumulate during roll mode display Turn Off accumulate 5 2 8 4 757 Cannot be executed when the acquisition mode is set to average Change the mode 7 3 758 Cannot copy if 50 pages is exceeded Change the multiplier or range 12 2 759 Realtime recording to the internal hard disk is valid when the record length is longer than 1 M 7 2 7 7 760 Cannot set the current drive on a realtime partition u...

Страница 276: ...egal date time Set the correct date and time 3 5 801 Illegal file name The file name contains characters which are not allowed or the file name is not a Chapter 13 valid MS DOS file name Enter another file name 803 Turn off accumulate mode to enter history menu It is not possible to activate the history menu by 8 4 pressing the HISTORY key during accumulation 804 Cannot change this parameter while...

Страница 277: ...aveform does not exist 11 9 865 Zones determination is not possible in the following cases 11 9 When the main window is not displayed When the relevant waveform is not displayed When the zone waveform does not exist 867 Conflict in the waveform display plane 11 9 Set the Mode to something other than Zone using the GO NO GO menu 868 Processing statistics 11 7 To perform other operations abort the s...

Страница 278: ...M failure Maintenance service is required 906 Fan stopped Power off immediately Maintenance service is required 907 Backup battery is flat Maintenance service is required to replace the back up battery 3 4 908 Internal temperature is too high Power off immediately Maintenance service is required 3 4 909 Illegal SUM value Maintenance service is required 3 4 910 RAM read write error Maintenance serv...

Страница 279: ...sk Chapter 13 If the same message still appears maintenance service is required 1019 File system failure Check using another disk Chapter 13 If the same message still appears maintenance service is required 1020 File system failure Check using another disk Chapter 13 If the same message still appears maintenance service is required 1021 File is damaged Check the file Chapter 13 1022 File system fa...

Страница 280: ...hapter 13 1048 Media failure Check the medium Chapter 13 1049 Media failure Check the medium Chapter 13 1050 Media failure Check the medium Chapter 13 1051 Media failure Check the medium Chapter 13 1052 Media failure Check the medium Chapter 13 1053 Media failure Check the medium Chapter 13 1054 Media failure Use a floppy disk of a format supported by the instrument 13 1 13 5 1055 Turn the HDD mot...

Страница 281: ...directory Chapter 13 1138 Cannot save at the current PDF setting 9 9 13 13 Change the settings A file of size exceeding 2 GB cannot be created 1139 Cannot create PDF files on the network drive when the history waveform display format is set to All 9 9 13 13 Create the file on the local drive and then copy it to the network drive Printer Errors 1200 to 1299 Code Message and Corrective Action Sectio...

Страница 282: ...or Client Handle Chapter 16 Confirm the network settings and connection 1315 FTP Error Others Chapter 16 Confirm the network settings and connection 1335 Cannot send data to a network printer Confirm the network settings and connection 12 4 16 4 1336 Cannot send a mail Confirm the network settings and connection 16 5 1345 Test Error Chapter 16 1346 Test Success Chapter 16 1348 Failed to initialize...

Страница 283: ...e changed during X Y recording 9 7 1607 Cannot use wave window trigger when the recorder mode is set to chart or X Y Chapter 9 1608 Cannot be specified when the print style is Numeric 9 6 1609 Cannot Set or Execute on the DL750 Chapter 9 Other Errors 9999 Code Message and Corrective Action Section 9999 This error No is not defined Note If servicing is required initialize the instrument once for co...

Страница 284: ...tem to be tested Proceed to step 5 for the memory test step 7 for the key test step 12 for the printer test and step 14 for the floppy disk drive test Zip disk drive test PC card drive test internal HDD test or SCSI test Executing the Memory Test 5 In step 4 select Memory 6 Press the Test Exec soft key to execute the memory test Executing the Key Test 7 In step 4 select Key Board 8 Press the Test ...

Страница 285: ...key 16 Turn the jog shuttle to set Test Type to 1 17 Press the Test Exec soft key to execute the test selected in step 14 Note Insert a floppy disk a Zip disk or a PC card before executing the floppy disk drive Zip disk drive or PC card drive test Note the following points when performing a SCSI test Connect the SCSI device Only test unpartitioned SCSI devices Set the SCSI ID to 1 Test Item Calib ...

Страница 286: ...ecution Internal Hard Disk Drive Optional or SCSI Test HDD SCSI Tests whether the internal hard disk drive or SCSI is operating correctly If there is an error Fail is displayed after the test execution Printer Test Tests whether the built in printer is operating properly If the tint is printed correctly the operation is normal If there is an error the printing will not be correct If an Error Occur...

Страница 287: ...nly Product ID Unique number attached to each instrument Required when expanding the instrument with options sold separately 1 The 701265 TEMP HPV and the 701280 FREQ are equipped with a CPU and firmware inside the modules On the channels in which these modules are inserted the version of the firmware installed in the module is also displayed on the screen 701265 TEMP HPV TEMP HPV 701265 X XX X XX...

Страница 288: ...uilt in printer DL750 Under normal usage 500 rolls of paper part No B9988AE Built in printer DL750P Under normal usage 1500 rolls of paper part No 701966 LCD backlight Approx 55000 hours under normal use Parts Name Warranty Period Internal hard disk One year after purchase data is excluded The following items are expendable items It is recommended that the parts be replaced according to the period...

Страница 289: ...waveform of cursor measurements and automated measurement of waveform parameters Can be used as a target channel for the dual capture function 19 2 Trigger Section Item Specifications Trigger mode Auto auto level normal single single N log and repeat only during Chart Recorder mode on the DL750P Trigger level range CH1 to CH16 10 div around 0 Trigger hysteresis When observing voltage Select 0 1 di...

Страница 290: ...r occurs when the period of condition T is outside a specified time range Specified time Time1 100 ns to 10 s Time2 200 ns to 10 s resolution is 100 ns Window Trigger occurs when the trigger source enters or exits the range specified by two points Window OR of multiple channels is possible Logic bits can also be included in the edge OR condition Wave Window Trigger for monitoring the power supply ...

Страница 291: ... 3 4 8 16 analog waveform windows Display interpolation Display samples using dot display sine interpolation or linear interpolation Graticule Select from three graticule types Auxiliary display ON OFF Turn ON OFF scale values waveform labels extra window level indicator numeric display X Y display Select the X axis and Y axis from CH1 to CH16 DSP1 to DSP6 MATH1 to MATH8 up to 4 Accumulation Accum...

Страница 292: ...P P Amp Max Min High Low Avg Mid Rms Sdev OvrShoot OvrShoot Rise Fall Freq Period Width Width Duty Pulse Burst1 Burst2 AvgFreq AvgPeriod Int1TY Int2TY Int1XY Int2XY Delay between channels Statistical processing Applicable items Automated measured values of waveform parameters described above Statistics Max Min Avg Sdv and Cnt Maximum number of cycles 48000 cycles when the number of parameters is 1...

Страница 293: ...ff characteristics 3 0 f fc 2 dB f frequency fc cutoff frequency Phase Linear phase characteristics IIR Butterworth filter Filter format IIR Butterworth Filter type LPF HPF BPF Filter order 4th order Characteristics Characteristics close to an analog filter flat pass band and overshoot LPF Cutoff frequency 0 2 to 30 of fs 0 2 resolution fs sampling frequency HPF Cutoff frequency 0 2 to 30 of fs 0 ...

Страница 294: ...umber smaller than itself can be specified The maximum sample rate of analog channels is 5 MS s when a DSP channel is turned ON Recorder Mode DL750P only Item Specifications Realtime recording on T Y waveform recording numeric value recording Output to the chart in realtime the built in printer X Y waveform recording Starts data acquisition with START and generates X Y waveforms in realtime Output...

Страница 295: ... preset message string Data Prints numeric measured values Select the print interval from OFF 200 400 and 800 mm During X Y waveform recording Prints the scale value Shot recording Automatically stops when the specified length is recorded after the start of measurement or after the trigger condition is met Shot recording length Continuous 20 cm 50 cm 1m or 2 m External start stop Shared with the G...

Страница 296: ... as an action for GO NO GO determination and action on trigger Calibration Auto calibration and manual calibration available System settings Sets the screen color date time message language and click sound ON OFF Probe compensation Outputs a signal rectangular signal of approx 1 VP P and approx 1 kHz from the probe signal output compensation output terminal on the front panel Overview Shows system...

Страница 297: ...B FAT32 2 partitions by factory default File name Supports long file names ANK16 characters Function Mount the internal HD via the SCSI port External Storage Interface SCSI Item Specifications Standard SCSI Small Computer System Interface ANSIX3 131 1986 Connector Half pitch 50 pins Connector pin assignment Unbalanced single ended USB Storage Device Item Specifications Compatible USB mass USB USB ...

Страница 298: ...vices whose maximum current consumption exceeds 100 mA cannot be connected simultaneously to the two ports 19 9 Auxiliary I O Section Logic Input Item Specifications Number of inputs 8 bits 2 Connector type 26 pin half pitch connector 2 Maximum sample rate 10 MS s Compatible probes Non isolated 700986 8 bits or isolated 700987 8 bits External Trigger Input Item Specifications Connector type RCA ja...

Страница 299: ...KOGAWA 366973 1 The terminal is also used as a GO NO GO Terminal COMP Output Rectangular Signal Output for Probe Compensation Item Specifications Output frequency 1 kHz 1 Output amplitude 1 V 10 Voice Input Output VOICE IN OUT SW 1 Item Specification Compatible earphone microphone Earphone microphone with a PUSH switch YOKOGAWA 701951 Dynamic inner earphone Input impedance 32Ω Frequency range 100 ...

Страница 300: ...mination I O terminal Probe Power Output Optional Item Specifications Number of output terminals 4 Output voltage 12 V 2 outputs up to a total of 800 mA Probes that can be used Current probe 700937 15 A up to 4 probes Current probe 701930 150 A up to 2 probes Current probe 701931 500 A 1 probe Current probe 701933 30 A up to 2 probes For details on the usage conditions of each probe see Relationsh...

Страница 301: ...eceptacle Electrical and mechanical Conforms to USB Rev 1 1 specifications Data rate 12 Mbps max Number of ports 1 Supported service Remote control2 PC system supported PCs with standard USB ports running Windows 98 SE or Windows 2000 A separate driver1 is required for connecting to a PC Ethernet Connector Optional 1 Item Specifications Number of communication 1 ports Electrical and mechanical Con...

Страница 302: ...supply and ground External dimensions 355 mm W 250 mm H 180 mm D excluding the handle and other projections Weight DL750 Approx 6 6 kg only the DL750 with all options M3 C8 C10 P4 options without the chart paper Approx 10 6 kg DL750 eight High Speed 10 MS s 12 Bit Isolation Modules DL750P Approx 7 8 kg only the DL750P with all options M3 C8 C10 P4 options without the chart paper Approx 11 8 kg DL7...

Страница 303: ...than approx 18 V Withstand voltage 30 VAC for one minute between the DC power input terminal and earth terminal Insulation resistance 10 MΩ or more at 500 VDC between the DC power terminal and earth External dimensions 355 mm W 250 mm H 200 mm D DL750 with the DC option installed excluding the handle and other projections Weight Approx 7 4 kg only the DL750 with all options M3 C8 C10 P4 DC options...

Страница 304: ...50 DL750P side SCSI interface connector Use shielded SCSI cable4 and attach a ferrite core TDK ZCAT2035 0930A YOKOGAWA A1190MN on one end DL750 DL750P side USB peripheral connector Use shielded USB cables4 USB interface connector When connecting a USB keyboard or mouse using a shielded cable or when connecting to a USB printer use shielded USB cables4 GO NO GO I O terminal Use a dedicated GO NO GO...

Страница 305: ...input filter with the tip of the probe 700929 10 1 shorted 701280 25 kS s envelope mode Frequency 0 1 Hz div no input filter User 1 V threshold level 0 V hysteresis 1 with the tip of the probe 700929 10 1 shorted Test Item 1 Electrostatic discharge EN61000 4 2 Air discharge 8 kV contact discharge 4 kV criteria B 2 Radiated immunity EN61000 4 3 80 MHz to 1 GHz 1 4 GHz to 2 GHz 10 V m Criteria A 3 C...

Страница 306: ...ned with the 701901 701954 1 1 5 400 Vrms CAT I 300 Vrms CAT II Direct input or cable not complying with the safety standard7 42 V DC ACpeak CAT I and CAT II 30 Vrms DC offset 5 div maximum selectable range Vertical voltage axis accuracy DC accuracy1 for 5 mV div to 20 V div 0 5 of 10 div Input connector BNC connector isolated type Input impedance 1 MΩ 1 approx 35 pF 3 dB point when AC 10 Hz or le...

Страница 307: ...rd operating conditions section 19 11 H L Combined with the 700929 2 3 700929 H L 701901 701954 4 Combined with the 701901 701954 H L Direct input cable not complying with the safety standard 6 7 BNC 5 Withstand voltage 1500 Vrms for 1 minute Allowable transient surge voltage 2100 Vpeak between earth and input 8 The typical value is a representative or standard value It is not strictly warranted W...

Страница 308: ...1 701954 1 1 5 400 Vrms CAT I 300 Vrms CAT II Direct input or cable not complying with the safety standard7 42 V DC ACpeak CAT I and CAT II 30 Vrms DC offset maximum 5 div selectable range Vertical voltage axis accuracy DC accuracy1 For 5 mV div to 20 V div 0 25 of 10 div 2 mV div 0 3 of 10 div 1 mV div 0 5 of 10 div Input connector BNC connector isolated type Input impedance 1 MΩ 1 approx 35 pF 3...

Страница 309: ...ard operating conditions section 19 11 H L Combined with the 700929 2 3 700929 H L 701901 701954 4 Combined with the 701901 701954 H L Direct input cable not complying with the safety standard 6 7 BNC 5 Withstand voltage 1500 Vrms for 1 minute Allowable transient surge voltage 2100 Vpeak between earth and input 8 The typical value is a representative or standard value It is not strictly warranted ...

Страница 310: ...el 400 mV or 0 06 div whichever is greater typical4 Input section shorted A D conversion resolution 12 bit 150 LSB div Temperature coefficient Zero point 5 mV div to 20 V div 0 05 of 10 div C typical4 Gain 0 02 of 10 div C typical4 Bandwidth limit Select from OFF 500 kHz 50 kHz 5 kHz and 500 Hz Cut off characteristics 18 dB OCT typical4 Probe attenuation setting Voltage probe 1 1 10 1 100 1 1000 1...

Страница 311: ...e earth grounding of the DL750 DL750P To prevent the possibility of electric shock be sure to fasten the module screws The module screws must be fastened for the module to function as a non isolation module In addition all electrical and mechanical protection functions are activated only when the screws are fastened The maximum input voltage of the module is valid only when all the screws are fast...

Страница 312: ...nput or cable not complying with the safety standard9 30 Vrms 42 VDC ACpeak across the input terminal H or L and earth DC offset 5 div maximum selectable range Vertical voltage axis accuracy1 Waveform observation mode DC accuracy 0 25 of 10 div RMS observation mode DC accuracy 1 0 of 10 div AC accuracy when a sine wave is input 1 5 of 10 div At frequency of AC accuracy when the crest factor is 2 o...

Страница 313: ...age 3700 Vrms for 1 minute 10 Typical value represents a typical or average value It is not strictly warranted WARNING When applying high voltage using this module use the 1 1 safety cable combination of 701901 and 701954 or the isolated probe 700929 The Measurement Category of the direct input of this module is 400 Vrms CAT II on the low side and 700 Vrms CAT II on the high side Use caution becau...

Страница 314: ...C 0 1 of reading 1 5 C E 200 to 800 C Except 0 2 of reading 1 5 C for 200 C to 0 C J 200 to 1100 C T 200 to 400 C L 200 to 900 C U 200 to 400 C N 0 to 1300 C R 0 to 1700 C 0 1 of reading 3 C S 0 to 1700 C Except 0 to 200 C 8 C 200 to 800 C 5 C B 0 to 1800 C 0 1 of reading 2 C Except 400 to 700 C 8 C Effective range is 400 to 1800 C W 0 to 2300 C 0 1 of reading 3 C Au7Fe3 0 to 300K 0 to 50K 4K 50 t...

Страница 315: ... 40 Hz Cutoff characteristics 12 dB OCT typical6 setting other than AUTO Cutoff frequency fc when set to AUTO 701262 only Sample Rate Cutoff Frequency fc 100 kHz or higher 40 kHz 100 Hz to 50 kHz 40 of the sample rate 50 Hz or less 20 Hz Cutoff characteristics for AUTO 65 dB at 2 fc typical6 Table of cutoff frequency characteristics of the anti aliasing filter AAF When the filter is set to Auto th...

Страница 316: ...age or allowable common mode input voltage To prevent the possibility of electric shock be sure to furnish protective earth grounding of the DL750 DL750P To prevent the possibility of electric shock be sure to fasten the module screws Otherwise the electrical and mechanical protection functions will not be activated ...

Страница 317: ...g 2 C However for400 to 700 C 8 C Effective range is 400 to 1800 C W 0 to 2300 C 0 1 of reading 3 C Au7Fe3 0 to 300 K 0 to 50K 4 K 50 to 300K 2 5 K Frequency characteristics1 3 dB point when a sine wave of amplitude of 3 divisions is input Voltage measurement DC to 100 Hz Temperature measurement DC to 100 Hz Maximum input voltage4 at a frequency of 1 kHz or less For both temperature and voltage in...

Страница 318: ... 1 Value measured under standard operating conditions section 19 11 2 Does not include the reference junction temperature compensation accuracy 3 This module supports Au7Fe with 0 07 metal content with respect to gold H L 5 4 6 The typical value is a representative or standard value It is not strictly warranted WARNING Do not apply input voltage exceeding the maximum input voltage or allowable com...

Страница 319: ...STR 10000 µ STR to 10000 µ STR 20000 µ STR 20000 µ STR to 20000 µ STR When using mV V range Measurement Range FS Measurement Range 0 25 mv V 0 25 mV V to 0 25 mV V 0 5 mV V 0 5 mV V to 0 5 mV V 1 mV V 1 mV V to 1 mV V 2 5 mV V 2 5 mV V to 2 5 mV V 5 mV V 5 mV V to 5 mV V 10 mV V 10 mV V to 10 mV V DC accuracy1 0 5 of FS 5 µ STR Maximum input voltage Between Input and Input 10 V DC ACpeak At 1 kHz ...

Страница 320: ...56 is used the connector shell cable shield and the bridge head case are all connected to the case potential of the DL750 DL750P When a bridge head 701955 or 701956 is used the floating GND is connected to the bridge head case inside the bridge head Be sure to execute balancing again when you change the range or the bridge voltage 1 Value measured under standard operating conditions section 19 11 ...

Страница 321: ...10000 µ STR 10000 µ STR to 10000 µ STR 20000 µ STR 20000 µ STR to 20000 µ STR When using mV V range Measurement Range FS Measurement Range 0 25 mv V 0 25mV V to 0 25 mV V 0 5 mV V 0 5mV V to 0 5 mV V 1 mV V 1mV V to 1 mV V 2 5 mV V 2 5mV V to 2 5 mV V 5 mV V 5mV V to 5 mV V 10 mV V 10mV V to 10 mV V DC accuracy1 0 5 of FS 5 µ STR Maximum input voltage Between Input and Input 10 V DC ACpeak At 1 kH...

Страница 322: ...is used the connector shell cable shield and the bridge head case are all connected to the case potential of the DL750 DL750P When a bridge head 701957 or 701958 is used the floating GND is connected to the bridge head case inside the bridge head Be sure to execute balancing again when you change the range or the bridge voltage 1 Value measured under standard operating conditions section 19 11 2 T...

Страница 323: ...pled Low0 4 Hz or less 0 04 Hz or less when using the 701940 typical4 frequency attenuation point Common mode rejection ratio 80 dB 50 60 Hz or more typical4 Residual noise level 100 µ V or 0 01 div whichever is greater typical4 Input section shorted A D conversion resolution 16 bits 2400 LSB div Temperature coefficient When in waveform measurement mode excluding AUTO filter Zero point 0 02 of 10 ...

Страница 324: ...measured under standard operating conditions section 19 11 H L 2 3 BNC Combined with the 10 1 passive probe 701940 Direct input cable not complying with the safety standard H L 2 3 4 Typical value represents a typical or average value It is not strictly warranted WARNING Do not apply input voltage exceeding the maximum input voltage withstand voltage or allowable surge voltage To prevent the possi...

Страница 325: ... frequency 0 001 Hz Input frequency of 2 kHz to 10 kHz 0 1 of the input frequency Input frequency of 10 kHz to 20 kHz 0 3 of the input frequency Input frequency of 20 kHz or higher 0 5 of the input frequency When in power supply frequency mode7 When the center frequency is 50 60 Hz 0 03 Hz 0 01 Hz resolution When the center frequency is 400 Hz 0 3 Hz 0 01 Hz resolution Input set to AC100V or AC200...

Страница 326: ...when pulse input is detected When overdriven Illuminates in red when the input voltage exceeds the range Compatible probes cables Connection cable 1 1 Recommended 1 366926 Voltage probe 10 1 safety probe Recommended 2 700929 10 1 safety probe 20 to 45 pF For measuring 1000 V DC ACpeak or less 1 Value measured under standard operating conditions section 19 11 H L Combined with the 700929 2 3 700929...

Страница 327: ...r negative pulse Minimum resolution 0 01 Power supply frequency Measurable frequency range 30 Hz to 70 Hz when the center frequency is 50 Hz 40 Hz to 80 Hz when the center frequency is 60 Hz 380 Hz to 420 Hz when the center frequency is 400 Hz Selectable vertical axis sensitivity range 0 1 Hz div to 2 Hz div 0 01 Hz resolution Center frequency setting Select 50 Hz 60 Hz or 400 Hz Minimum resolutio...

Страница 328: ...ed time Specified time 0 1 to 1000 ms 0 1 ms resolution Can be specified on all measurement parameters Pulse average Performs frequency measurement per specified number of pulses When fluctuation exists periodically in the pulse interval the fluctuation can be eliminated Specified number of pulses 1 to 4096 Can be specified when measuring the frequency RPMs RPSs power supply frequency period pulse...

Страница 329: ...n of AC type of 80 VAC to 250 VAC 50 60 Hz Threshold level During DC input 6 V 50 Hi level 10 to 250 VDC Lo level 0 to 3 VDC During AC input 50 VAC 50 Hi level 80 to 250 VDC Lo level 0 to 20 VAC Response time During DC input within 1 ms During AC input within 20 ms Input impedance approx 100 kΩ Maximum input voltage 250 Vrms1 CAT I and II across H and L of each bit Maximum allowable 250 Vrms1 CAT ...

Страница 330: ... IM 701210 06E 19 14 External Dimensions DL750 Unit mm 355 13 5 180 21 8 2 250 4 8 180 8 2 DC Power Model 8 20 If not specified the tolerance is 3 However in cases of less than 10 mm the tolerance is 0 3 mm ...

Страница 331: ...6E Specifications 19 DL750P Unit mm 13 5 355 250 8 225 9 4 ACQ MEMORY BACKUP BATTERIES Rear View If not specified the tolerance is 3 However in cases of less than 10 mm the tolerance is 0 3 mm 19 14 External Dimensions ...

Страница 332: ...h Resolution 1 MS s 16 Bit Isolation Module 701251 High Speed 10 MS s 12 Bit Non Isolation Module 701255 High Voltage 100 kS s 16 Bit Isolation Module with RMS 701260 Universal Voltage Temp Module 701261 Universal Voltage Temp Module with AAF 701262 Temperature High Precision Voltage Isolation Module 701265 Strain Module NDIS 701270 Frequency Module 701280 Acceleration Voltage Module with AAF 7012...

Страница 333: ...100 k 50 k 20 k 10 k 5 k 2 k 1 k 500 200 100 100 100 50 50 50 20 10 5 50 100 200 500 1 k 2 k 5 k 5 k 4 k 5 k 5 k 4 k 5 k 5 k 4 k 5 k 5 k 4 k 5 k 5 k 4 k 3 k 4 k 5 k 3 k 4 k 5 k 4 k 3 k 3 k Record Length 1 kW 2 5 kW 5 kW Sample Rate S s Sample Rate S s Display Record Length Word Display Record Length Word Display Record Length Word Sample Rate S s 10 M 10 M 10 M 10 M 10 M 10 M 10 M 10 M 5 M 2 M 1 M...

Страница 334: ... 10 M 10 M 5 M 2 M 1 M 500 k 200 k 100 k 50 k 20 k 20 k 20 k 10 k 10 k 10 k 5 k 2 k 1 k 500 500 200 200 200 200 200 100 100 100 100 50 20 10 5 5 5 50 100 200 500 1 k 2 k 5 k 10 k 20 k 50 k 100 k 200 k 500 k 1 M 1 M 1 M 1 M 1 M 1 M 1 M 1 M 600 k 800 k 1 M 600 k 800 k 1 M 1 M 600 k 600 k 600 k 900 k 480 k 600 k 720 k 840 k 960 k 540 k 600 k 720 k 900 k 900 k 720 k 720 k 540 k 720 k 900 k Record Leng...

Страница 335: ...200 k 100 k 50 k 20 k 20 k 20 k 10 k 10 k 10 k 10 k 5 k 5 k 5 k 5 k 2 k 1 k 500 200 200 200 200 100 100 100 100 100 50 20 10 50 100 200 500 1 k 2 k 5 k 10 k 20 k 50 k 100 k 200 k 500 k 1 M 2 M 5 M 10 M 20 M 50 M 50 M 40 M 30 M 40 M 50 M 30 M 40 M 50 M 40 M 30 M 30 M 24 M 36 M 48 M 30 M 36 M 42 M 48 M 27 M 30 M 36 M 45 M 36 M 36 M 36 M 21 6 M 28 8 M 36 M 43 2 M 25 2 M 28 8 M 32 4 M 36 M 43 2 M 43 2...

Страница 336: ...00 M 900 M 480 M 600 M 720 M 840 M 960 M 540 M 600 M 720 M 900 M 900 M 720 M 720 M 540 M 720 M 900 M 432 M 504 M 576 M 648 M 720 M 864 M 864 M 864 M 518 4 M Record Length 500 MW 1 GW Sample Rate S s Display Record Length Word Display Record Length Word Sample Rate S s For the settings inside the thick frame the waveform is displayed in roll mode when the trigger mode is set to auto or auto level 1...

Страница 337: ...el Number of Displayed Channels Standard M1 10 M M2 25 M M3 50 M Record length unit Word When the Acquisition Mode Is Set to Average 1 to 22 channels 1 M 2 5 M 5 M 10 M Model Number of Displayed Channels Standard M1 10 M M2 25 M M3 50 M Record length unit Word Maximum Number of Acquisitions of History Memory The maximum number of acquisitions per model is as follows 1 k 2 5 k 5 k 10 k 25 k 50 k 10...

Страница 338: ...s Range Maximum Maximum Record Length Sample Rate 18CH or more 20 s div to 3 day div 25 MW 5 kS s 12 to 17CH 20 s div to 3 day div 50 MW 5 kS s 6 to 11CH 10 s div to 3 day div 50 MW 10 kS s 4 to 5CH 6 s div to 3 day div 100 MW 20 kS s 3CH 3 s div to 3 day div 250 MW 50 kS s 2CH 1 s div to 3 day div 500 MW 100 kS s 1CH 1 s div to 3 day div 1 GW 100 kS s Appendix 2 Relationship between the Record Le...

Страница 339: ... S1 S3 S2 Integ1XY 1 Multiple Loops S0 Start Point Stop Point Area S n S0 n Number of Loops 2 Non Closed Curve S0 Start Point Area S S0 Area Enclosed by a Curve Connecting the Start and Stop Points Stop Point 3 Loop Tracing a Figure Eight Area S S0 S1 4 Spiral Loop Area S S0 2 S1 Number of Overlaps Varies According to the Number of Loops Stop Point S0 S1 Start Point Stop Point Start Point S0 Wavef...

Страница 340: ...ea S S0 Stop Point Start Point S0 2 4 Stop Point Start Point S0 Area S S0 S1 X axis Y 0 X Axis Y 0 Area S S0 Start Point Stop Point S0 2 When the Waveform Extends into the Negative Side X Axis Y 0 S0 S1 Start Point Stop Point 2 When Two or more Y Data Correspond to X Data X Axis Y 0 S0 Start Point Stop Point Area S S0 X Axis Y 0 S0 Stop Point Start Point Area S S0 2 S1 S2 S1 S2 Area S S0 ...

Страница 341: ...7 32767 32767 32767 VMinData 32767 32767 32767 32767 HResolution 2 0000000E 04 2 0000000E 04 2 0000000E 04 2 0000000E 04 HOffset 2 0018000E 00 2 0018000E 00 2 0018000E 00 2 0018000E 00 HUnit s s s s Date 2004 1 15 2004 1 15 2004 1 15 2004 1 15 Time 14 25 38 54 14 25 38 54 14 25 38 54 14 25 38 54 Group2 TraceNumber 4 BlockNumber 1 TraceName CH5 CH6 CH7 CH8 BlockSize 10010 10010 10010 10010 VResolut...

Страница 342: ...S2 VUnit Hz Hz EU EU VPlusOverData VMinusOverData VIllegalData 32768 32768 32768 32768 VMaxData 32767 32767 32767 32767 VMinData 32767 32767 32767 32767 HResolution 2 0000000E 04 2 0000000E 04 2 0000000E 04 2 0000000E 04 HOffset 2 0018000E 00 2 0018000E 00 2 0018000E 00 2 0018000E 00 HUnit s s s s Date 2004 1 15 2004 1 15 2004 1 15 2004 1 15 Time 14 25 38 54 14 25 38 54 14 25 38 54 14 25 38 54 Gro...

Страница 343: ...00V 250 00V 25 000V 25 000V 25 000V 25 000V 5000 0Hz 5000 0Hz 4 50000E 00EU 250 000E 03EU PLowerScaleData 4 00E 00 250 0V 250 00V 250 00V 25 000V 25 000V 25 000V 25 000V 5000 0Hz 5000 0Hz 500 000E 03EU 250 000E 03EU POffsetName 0 00000V 0 00000V 0 00000V 0 00000V 0 00000V 0 00000V 0 00000V 0 00000V 0 00000Hz 0 00000Hz Note The same header file format is used by all YOKOGAWA measuring instruments s...

Страница 344: ...xis of each waveform no effect on the data VPlusOverData Error data when the binary data of each waveform is greater than or equal to this value VMinusOverData Error data when the binary data of each waveform is less than or equal to this value VMaxData Maximum value of binary data for each waveform VMinData Minimum value of binary data for each waveform HResolution Value of coefficient HResolutio...

Страница 345: ...ing Data Big Motorola 68000 family data Ltl Intel 86 family data 2 Storage Format of the Binary Waveform Data Trace Groups into blocks each block for a single waveform Block Groups into blocks each block for a given time interval Trace is used on the DL750 DL750P 3 Binary File Start Position Offset from the beginning of the file 4 Maximum Number of Blocks in the Group Maximum number of blocks appl...

Страница 346: ... 2 HighPass 4 4 4 4 3 Filter Characteristics Filter Pass band Attenuation Slope Attenuation at the Phase Ripple Stop band Gauss 0dB 1 Linear phase Sharp 0 3 dB 40 dB at 1 oct Lowpass 40 dB Linear phase 40 dB at 1oct Highpass IIR 0 dB 5 dB at 1 6 oct Lowpass Not linear phase 20 dB at 1 oct Highpass 1 For Gaussian filter 3 0 f fc 2 dB f frequency fc cutoff frequency Frequency Characteristics of Filt...

Страница 347: ...transforming a signal in the time domain the signal is transformed into the frequency domain first using the Fourier transform Next the phase of each frequency component is shifted by 90 deg if the frequency is positive and 90 deg if negative Lastly taking the inverse Fourier transform completes the Hilbert transform Application Example Hilbert transform can be used to analyze an envelope waveform...

Страница 348: ... n 4 x Equation for First Order Derivative Point x0 f0 25f0 48f1 36f2 16f3 3f4 Point x1 f1 3f0 10f1 18f2 6f3 f4 Point x2 f2 f0 8f1 8f3 f4 Point xk fk fk 2 8fk 1 8fk 1 fk 2 Point xn 2 fn 2 fn 4 8fn 3 8fn 1 fn Point xn 1 fn 1 fn 4 6fn 3 18fn 2 10fn 1 3fn Point xn fn 3fn 4 16fn 3 36fn 2 48fn 1 25fn h x is the sampling interval s example h 200 10 6 for 5 kHz 1 12h 1 12h 1 12h 1 12h 1 12h 1 12h 1 12h E...

Страница 349: ... 1 2 1 2 1 2 1 2 1 2 fn 1 fn h Equation for Second Order Integration IINTG Point x0 II0 0 Point x1 II1 I0 I1 h Point x2 II2 I0 I1 h I1 I2 h II1 II I2 h Point xn IIn IIn 1 1 2 1 2 1 2 1 2 1 2 In 1 In h Binary Conversion BIN Performs binary conversion with respect to the specified threshold level For the procedure in setting the threshold level see section 10 2 Binary Computation BIN C1 1 0 Upper th...

Страница 350: ...on Each frequency component G of a linear spectrum is represented by G R jI R real part I imaginary part Linear Spectrum Linear spectrum is a spectrum that can be directly determined with the FFT The magnitude and phase of each frequency component included in the measured waveform can be found The power spectrum and cross spectrum can also be determined from one or two linear spectrums Because the...

Страница 351: ...having a line spectrum such as sine waves The following spectrums can be determined with this instrument Item Equation Computation Magnitude PSD MAG PS MAG f for rectangular window PS MAG 1 5 f for Hanning window Log magnitude PSD LOGMAG 10 logPS MAG f for rectangular window 10 logPS MAG 1 5 f for Hanning window Log magnitude reference 0 dB 1 Vrms2 Overall Value The overall value is the total RMS ...

Страница 352: ...the ratio of the cross spectrum of the input and output Gyx and the input power spectrum Gxx Transfer Function Gy Gx Gy Gx Gx Gx Gyx Gxx Ryx jIyx Rx2 Ix2 The following items can be determined with this instrument Item Equation Computation Real part TF REAL Ryx Rx2 Ix2 Imaginary part TF IMAG Iyx Rx2 Ix2 Amplitude TF MAG Ryx2 Iyx2 2 Rx2 Ix2 Log magnitude TF LOGMAG 20 log Ryx2 Iyx2 2 Rx2 Ix2 Phase TF...

Страница 353: ...ugh impulse excitation On the DL750 DL750P the exponential window and force window are activated simultaneously Exponential Window The damping rate is set in terms of the weight of the last data point when taking the weight of the first data point in the specified number of FFT points to be 100 1 The value is set in the range of 1 to 100 1 resolution The exponential window damps the signal exponen...

Страница 354: ...nd the data outside the area is taken into account Weight Application Example on the DL750 DL750P 0 20 Source data Computed result by the exponential window Computed result by the exponential and force windows 40 60 80 100 0 0 5 1 1 5 2 Record length The data outside the area 80 to 100 of the record length is computed using an average value of the area at a constant damping rate When the damping r...

Страница 355: ...nnels can use the following FIR filters SHARP GAUSS MEAN moving average Signal Block Diagram of an FIR Filter Z 1 Z 1 Z 1 Z 1 Z 1 a1 a0 a2 a3 an 2 an 1 Z 1 ak Input Output nth order FIR number of taps n IIR IIR digital filter The signal block diagram of the computation is shown below The characteristics of IIR filters are as follows 1 Sufficient cutoff characteristics are obtained even at a relati...

Страница 356: ...hase 2 to 30 High Pass GAUSS 0 3 dB 3 0 f fc 2 dB Linear phase 2 to 30 MEAN 0 dB See characteristics diagram Linear phase moving average IIR 0dB 24 dB OCT Butterworth Low Pass 24 dB OCT Not linear phase 0 2 to 30 High Pass Group Delay Characteristics Group delay refers to the delay of the output frequency with respect to the input frequency sine wave due to the response characteristics of the filt...

Страница 357: ...ass and 1 2 high pass the cutoff frequency The attenuation in the stop band is 40 dB or greater Has linear phase characteristics and constant group delay 80 60 40 20 0 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f fc 2 fc 0 3 dB 40 dB SHARP Low pass Frequency Characteristics Example dB 80 60 40 20 0 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f fc 1 2 fc 0 3 dB 40 dB SHARP High pass Frequency Characteristics Example dB f...

Страница 358: ...s linear phase characteristics and constant group delay 80 60 40 20 0 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f fcl fcu fcus 1 2 fcl fcl 1 2 fcl fcus fcu Center frequency Passband 0 3 dB 40 dB 40 dB SHARP Band pass Frequency Characteristics Example dB f sampling frequency Hz For SHARP band pass filters the center frequency that can be specified is limited by the pass band width Selectable Range of SHARP B...

Страница 359: ...Order Pass band Width 2 Center frequency 3 4 5 6 7 8 9 10 Order 189 142 93 80 69 61 54 49 Center frequency 11 12 13 14 15 16 17 18 Order 45 41 37 34 32 27 20 18 Center frequency 24 25 26 19 20 21 22 23 Order 18 17 16 16 14 14 14 13 Center frequency 27 28 29 30 Order 13 12 13 11 SHARP Band pass Filter Order Pass band Width 5 Center frequency 5 6 7 8 9 10 11 12 Order 154 112 93 72 64 58 51 40 Center...

Страница 360: ...9 30 Order 25 24 20 Computation Delay The group delay can be derived from the following equation It is constant and depends on the filter order Group delay Filter order 1 2 Unit s Ts where Ts is the sampling frequency s The computation delay can be derived from the following equation Computation delay 4 filter order 1 2 sampling period However if the sampling frequency exceeds 100 kHz it is fixed ...

Страница 361: ...pass Frequency Characteristics dB SHARP Band pass Pass band Width 2 80 60 40 20 0 5 10 20 SHARP Band pass Frequency Characteristics Pass band Width 2 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f dB SHARP Band pass Pass band Width 5 80 60 40 20 0 5 10 20 SHARP Band pass Frequency Characteristics Pass band Width 5 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f dB f sampling frequency Hz ...

Страница 362: ... Width 10 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f dB SHARP Band pass Pass band Width 15 80 60 40 20 0 10 20 SHARP Band pass Frequency Characteristics Pass band Width 15 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f dB SHARP Band pass Pass band Width 20 80 60 40 20 0 20 SHARP Band pass Frequency Characteristics Pass band Width 20 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f dB f sampling frequency Hz ...

Страница 363: ...Order 49 33 25 21 17 17 13 13 Cutoff frequency 10 11 12 13 14 15 16 17 Order 9 9 9 9 9 9 9 5 Cutoff frequency 18 19 20 21 22 23 24 25 Order 5 5 5 5 5 5 5 5 Cutoff frequency 26 27 28 29 30 Order 5 5 5 5 5 Computation Delay The group delay can be derived from the following equation It is constant and depends on the filter order Group delay Filter order 1 2 Unit s Ts where Ts is the sampling frequenc...

Страница 364: ...IM 701210 06E Characteristics Examples 80 60 40 20 0 2 5 10 15 30 25 20 GAUSS Frequency Characteristics dB f sampling frequency Hz 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f Appendix 6 DSP Channel Computation Optional ...

Страница 365: ...cy Has non linear phase characteristics Lower frequencies can be specified as compared to other FIR filters 80 60 40 20 0 fc 3 dB 24 dB 2fc IIR Butterworth Low pass Frequency Characteristics Example 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f dB 80 60 40 20 0 fc 1 2 fc 3 dB 24 dB IIR Butterworth High pass Frequency Characteristics Example 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f dB f sampling frequency Hz Appendix...

Страница 366: ...assband Region 1 0 6 30 0 1 to 1 1 29 5 to 30 5 2 1 2 30 0 2 to 2 2 29 to 31 5 2 6 30 0 1 to 5 1 27 5 to 32 5 10 5 2 30 0 2 to 10 2 25 to 35 15 7 6 30 0 1 to 15 1 22 5 to 37 5 20 10 2 30 0 2 to 20 2 20 to 40 Computation Delay In the case of IIR filters the computation delay cannot be determined uniquely unlike FIR filters Because IIR filters do not have linear phase characteristics the delay varie...

Страница 367: ...aracteristics 0 20 2 5 10 15 20 25 30 dB 0 50 100 150 200 250 300 350 s T s IIR Butterworth Low pass Group Delay Characteristics 1 0 20 2 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 2 4 6 8 10 12 14 s T s IIR Butterworth Low pass Group Delay Characteristics 2 5 10 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz Appendix 6 DSP Channel Computation Optional ...

Страница 368: ... 0 3 f 0 4 f 0 5 f dB 0 50 100 150 200 250 300 350 s T s IIR Butterworth High pass Group Delay Characteristics 1 0 20 2 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 2 4 6 8 10 12 14 s T s IIR Butterworth High pass Group Delay Characteristics 2 5 10 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz Appendix 6 DSP Channel Computation Optional ...

Страница 369: ...0 2 f 0 3 f 0 4 f 0 5 f dB 0 50 100 150 200 250 300 350 s T s IIR Butterworth Band pass Group Delay Characteristics 1 Pass band Width 1 0 60 2 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 10 20 30 40 50 60 70 s T s IIR Butterworth Band pass Group Delay Characteristics 2 Pass band Width 1 5 10 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz Appendix 6 DSP Channel Computation Optional ...

Страница 370: ...0 3 f 0 4 f 0 5 f dB 0 20 40 60 80 100 120 140 160 s T s IIR Butterworth Band pass Group Delay Characteristics 1 Pass band Width 2 1 20 2 0f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 5 10 15 20 25 30 35 s T s IIR Butterworth Band pass Group Delay Characteristics 2 Pass band Width 2 5 10 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz Appendix 6 DSP Channel Computation Optional ...

Страница 371: ...ss band Width 5 30 25 20 15 10 5 2 6 dB 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 50 100 150 200 250 s T s IIR Butterworth Band pass Group Delay Characteristics 1 Pass band Width 5 2 6 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 2 4 6 8 10 12 14 16 18 s T s IIR Butterworth Band pass Group Delay Characteristics 2 Pass band Width 5 5 10 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz ...

Страница 372: ... Width 10 30 25 20 15 10 5 2 dB 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 20 40 60 80 100 120 140 s T s IIR Butterworth Band pass Group Delay Characteristics 1 Pass band Width 10 5 2 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 1 2 3 4 5 6 7 8 9 10 s T s IIR Butterworth Band pass Group Delay Characteristics 2 Pass band Width 10 10 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz ...

Страница 373: ... f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 50 100 150 200 250 s T s IIR Butterworth Band pass Group Delay Characteristics 1 Pass band Width 15 7 6 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 2 4 6 8 10 12 14 s T s IIR Butterworth Band pass Group Delay Characteristics 2 Pass band Width 15 10 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz Appendix 6 DSP Channel Computation Optional ...

Страница 374: ... 0 2 f 0 3 f 0 4 f 0 5 f 0 20 40 60 80 100 120 140 s T s IIR Butterworth Band pass Group Delay Characteristics 1 Pass band Width 20 10 2 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f 0 1 2 3 4 5 6 7 s T s IIR Butterworth Band pass Group Delay Characteristics 2 Pass band Width 20 15 20 25 30 0 f 0 1 f 0 2 f 0 3 f 0 4 f 0 5 f f sampling frequency Hz Appendix 6 DSP Channel Computation Optional ...

Страница 375: ...ampling frequency Hz Computation Delay The group delay can be derived from the following equation It is constant and depends on the filter order Group delay Number of moving average points 1 2 Unit s Ts where Ts is the sampling frequency s The computation delay can be derived from the following equation Computation delay 4 Number of moving average points 1 2 sampling clock cycle However if the sam...

Страница 376: ...pling frequency At higher frequencies the high frequency characteristics of the Lagrange Interpolation Formula suppress the high frequency components Computation Delay The computation delay is as follows Computation delay 4 21 sampling period 1 2 delay due to the Lagrange Interpolation However if the sampling frequency exceeds 100 kHz it is fixed to 100 kHz 10 µs It is also fixed to 100 kHz 10 µs ...

Страница 377: ... using floating point decimal format inside the DSP Example C Float A Float B Float Calculation of the 1 LSB Weight of the Output The 1 LSB weight of the output is determined from the DSP range Value DIV Since 1 DIV 2400 LSB 1 LSB weight of the output Value DIV 2400 Computation Output Conversion from Floating Point to 16 Bit Binary The output is converted into 16 bit data according to the followin...

Страница 378: ...le OFF Position 0 00 div Coupling DC BandWidth Full V Zoom 1 Offset 0 000 V Linear Scale OFF InVert OFF Label Channel number Key Soft Key Default Setting CH1 to 16 TEMP HPV 701265 V div 5 000 V div Variable OFF Position 0 00 div Coupling DC BandWidth Full V Zoom 1 Offset 0 000 V Linear Scale OFF Invert OFF Label Channel number CH1 to 16 STRAIN_NDIS 701270 STRAIN_DSUB 701271 Range Unit µSTR Range 2...

Страница 379: ... YTrace Start Point 5 div End Point 5 div Key Soft Key Default Setting MATH Mode OFF Operation Math1 OFF Operation Math2 OFF Operation Math3 OFF Operation Math4 OFF Operation Math5 OFF Operation Math6 OFF Operation Math7 OFF Operation Math8 OFF Start Point 5 div End Point 5 div Threshold Trace CH1 Threshold Upper 0 0 V Threshold Lower 0 0 V Average Mode OFF Phase Shift 0 000 msec Filter Select FIL...

Страница 380: ...File Item Setup Auto Naming Numbering PRINT MENU Print to Printer Format Normal Time Range1 5 div Time Range2 5 div LongCopy Mag 500 µs div SETUP Auto Setup 0 V Trace All CAL Auto Cal ON MISC System Config Date Time 2002 01 01 System Config Menu Language Eng System Config Message Language Eng System Config Click Sound ON SCSI ID Own ID 6 SCSI ID Internal ID 4 Others Video Out ON Others HDD Motor O...

Страница 381: ... as left SIMPLE ENHANCED menu Same as left ZOOM menu SEARCH menu CH1 menu CH2 menu CH3 menu CH4 menu DSP1 menu DSP2 menu DSP3 menu DSP4 menu CH5 menu CH6 menu CH7 menu CH8 menu DSP5 menu DSP6 menu CH9 menu CH10 menu Logic A menu Logic B menu Return Enter Select Same as left B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9 0 Enter 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1...

Страница 382: ...Down Numeric Num Lock Enter 1 2 3 4 5 Select Soft key1 Select Soft key2 Select Soft key3 Select Soft key4 Select Soft key5 Select Soft key6 Select Soft key7 Escape µ Ω Insert condition 1 Cursor to the right Cursor to the left Select Soft key6 Select Soft key6 Same as left Same as left Same as left Same as left Same as left Same as left Same as left Same as left Select Soft key1 Select Soft key2 Se...

Страница 383: ...9 menu CH10 menu Logic A menu Logic B menu Return Enter Select Same as left B C D E F G H I J K L M N O P Q R S T U V W X Y Z 1 2 3 4 5 6 7 8 9 0 Enter 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Escape MISC menu Same as left Same a...

Страница 384: ... End Page Down Numeric Num Lock Enter 1 2 3 4 5 Seletc Soft key1 Seletc Soft key2 Seletc Soft key3 Seletc Soft key4 Seletc Soft key5 Seletc Soft key6 Seletc Soft key7 Escape µ Ω Insert condition 1 Cursor to the right Cursor to the left Seletc Soft key6 Seletc Soft key6 Same as left Same as left Same as left Same as left Same as left Same as left Same as left Same as left Seletc Soft key1 Seletc So...

Страница 385: ...re When Start Mode Power On Is ON When the Backup Switch Is OFF The history memory is cleared Waveform acquisition starts regardless of whether measurement was in progress before the power failure When the Backup Switch Is ON The history memory is held If waveform acquisition was in progress before the power failure the waveform acquisition is resumed 1 Waveform acquisition starts if measurement w...

Страница 386: ...V and Strain ε of the Wheatstone Bridge 1 Gauge Method If we assume V to be the voltage measured on the bridge and E to be the voltage applied to the bridge V 1 4 E R R 4 From equation 3 R R K ε Thus V 1 4 E K ε 5 When Determining the Strain ε from the Measured Voltage V Strain Gauge 1 Gauge Method If we derive ε from equation 5 ε 4 K V E 6 When Determining the Measured Value of the Strain Gauge S...

Страница 387: ...Head 701957 701958 with shunt cal support Bridge Bridge Input Input Input Input Sense Sense Sense Sense Shuntcal Shunt resistor Shuntcal Shuntcal Shuntcal R R R 9 6 8 7 5 2 4 3 1 Shell Twist Twist Twist Shield Twist 9 6 8 7 5 2 4 3 1 Shell Bridge Bridge Input Input Sense Sense Suntcal Suntcal Floating Common Floating Common Floating Common ON OFF Shuntcal Sense Sense Sense Sense 701271 STRAIN_DSUB...

Страница 388: ...value Before execution After execution Before execution After execution Gain is corrected 1 Automatically obtained when shunt calibration is executed 1 Execution Menu of Shunt Calibration The execution menu of shunt calibration is set using channel menu Linear Scale Mode In normal shunt calibration only P2 Y is set In addition to the normal shunt calibration when the shunt calibration relay circui...

Страница 389: ...hunt calibration the shunt resistance Rs and the expected strain ε need to be calculated in advance Use ε as given in the equation below normally a negative value With the DL750 DL750P enter the value into P2 Y under the shunt calibration execution menu However when using the general method given for shunt calibration the easy method an error of 1 to 2 can be introduced as the strain value ε incre...

Страница 390: ... Shunt resistance shunt resistance you wish to derive R Combined resistance when the relay is turned ON R R Rs V0 E R1 R3 R2 R4 R1 R2 R3 R4 When shunt calibration is ON V0 E R1 R3 R R4 R1 R R3 R4 R R2 Rs R1 R2 R3 R4 R Also from the basic equation of strain V0 E K ε 4 If V0 E and R1 to R4 are cancelled out from 2 3 4 and 5 Rs R 1 K ε 2 K ε Equation B Detailed equation used to calculate the shunt re...

Страница 391: ...0 17 325 5 880 17 150 When Determining the Corresponding Strain ε from the Shunt Resistance Rs If we derive e from equation 6 and 7 Detailed equation ε 1 1 2 Rs R 8 equation B General equation ε 1 2 1 Rs R 9 Error of 1 to 2 present equation A When the Bridge Resistance R is 120 Ω RS Value Ω Strain ε µSTR Derived by Strain ε µSTR Derived by the Detailed Equation 8 the General Equation 9 60 000 999 ...

Страница 392: ... C The frequency f is calculated as 1 period t When the period of the input pulse spans over multiple measurement intervals computation is performed at the measurement interval following the interval in which the edge is detected Input pulse Measurement interval 40 µs Time T1 Time T2 A B Period t Period t T2 T1 Frequency f 1 period t 40 µs C 40 µs 2 When the input signal is greater than or equal t...

Страница 393: ...s T1 T2 and T3 in measurement intervals A and B In measurement interval C For pulse width Calculates pulse width T2 T1 For duty cycle Calculates duty cycle T2 T1 T3 T1 Input pulse Time T1 Time T2 Time T3 Pulse width T2 T1 Duty cycle T2 T1 T3 T1 Pulse width Measurement interval 40 µs A B 40 µs C 40 µs 2 When the input signal is greater than or equal to 25 kHz Measures the times of occurrences of pu...

Страница 394: ...nt value obtained using the 32 bit counter with 50 ns resolution to floating point format and determines period A using the following equation Period A float count value 50 ns Computation Various computations are performed in floating point format based on the settings Example Frequency C float 1 A float Calculation of the 1 LSB Weight of the Output The 1 LSB weight of the output is determined fro...

Страница 395: ...ter are as follows The filter is a low pass filter Pass band is flat Has linear phase characteristics and constant group delay by filter order The group delay is derived using the following equation Group delay the number of points of moving average 1 40 µs 2 Has comb shaped bandwidth characteristics See page app 43 The figure below shows the result when the smoothing filter is applied to a wavefo...

Страница 396: ...e 10 V Coupling DC Probe 1 1 Bandwidth Yes2 Threshold 2 5 V Hys Yes3 Slope Yes4 Chatter Elimination Yes5 Pull Up Yes6 ZeroCross Setup Item Setting V Range Yes7 Coupling AC Probe Yes1 Bandwidth Yes2 Threshold 0 V Hys Yes3 Slope Rising edge Chatter Elimination Yes5 Pull Up No When you select a preset the setup items are automatically set to the settings in the table The meaning of Yes and No in the ...

Страница 397: ...robe Yes1 Bandwidth Yes2 Threshold Yes9 Hys Yes3 Slope Yes4 Chatter Elimination Yes5 Pull Up No When you select a preset the setup items are automatically set to the settings in the table The meaning of Yes and No in the table is as follows Yes Item that can be set to an arbitrary value No Item that cannot be set not displayed on the menu 1 Probe type Select 1 1 or 10 1 2 Bandwidth limit Select 10...

Страница 398: ...nt 80 World Wide Web HTTP Web server and WebDAV server 515 LPR client 10001 Instrument control via the Ethernet interface UDP Port Numbers Port Number Description Function 67 Bootstrap Protocol Server DHCP client 68 Bootstrap Protocol Client receive wait port 123 Network Time Protocol SNTP client The port number when FTP passive mode see section 16 10 is turned OFF If FTP passive mode is turned ON...

Страница 399: ...in 200 2 4 M 1000 3 33 h 25 mm min 100 2 4 M 1000 6 66 h 20 mm min 50 1 5 M 1000 8 33 h 10 mm min 20 1 2 M 1000 16 6 h 5 mm min 20 2 4 M 1000 1 38 day 2 mm min 5 1 5 M 1000 3 47 day 1 mm min 5 1 5 M 500 3 47 day 100 mm h 5 1 8 M 1000 4 16 day 50 mm h 5 1 8 M 500 4 16 day 25 mm h 5 1 8 M 250 4 16 day 20 mm h 5 1 8 M 200 4 16 day 10 mm h 5 1 8 M 100 4 16 day The sample rates in the table above are t...

Страница 400: ...9 Attached Image File 16 17 Attenuation 2 9 5 9 Attenuation Weight 7 6 Author 9 28 13 51 Auto Trigger Mode 2 27 2 34 2 43 6 1 7 13 9 7 Auto Calibration 4 21 Auto Level Trigger Mode 2 27 6 1 Auto Naming 7 17 13 24 13 29 13 41 Auto OFF 17 6 Auto Print 9 18 Auto Scroll 2 54 11 13 11 15 Auto Setup 2 62 4 18 Automated Measurement of Waveform Parameter2 56 11 31 Auxiliary I O Section 19 10 Average 10 21...

Страница 401: ... 3 Display Bits 5 56 5 58 Display Format 8 1 Display Format of Logic Waveforms 11 28 Display Interpolation 2 37 DISPLAY Key 1 8 Displayed Record Length 2 31 Displaying Waveforms on a Full Screen 8 22 Div Page 9 28 Dividing 10 1 Division 2 47 Division DSP Channel 15 3 Division with Coefficient DSP Channel 15 13 DNS 16 6 DNS Server 16 6 Document Information 9 28 13 51 Domain Suffix 16 6 Dot Display ...

Страница 402: ...el 14 2 High Voltage Differential Probe 3 20 High Speed 10 MS s 12 Bit Isolation Module 1 4 3 6 19 18 19 44 High Speed 10 MS s 12 Bit Non Isolation Module 1 4 3 6 19 22 19 44 High Speed High Resolution 1 MS s 16 Bit Isolation Module 1 4 3 6 19 20 19 44 High Speed Logic Probe 3 28 High Voltage 100 kS s 16 Bit Isolation Module with RMS 1 4 3 6 19 24 19 44 Hilbert App 15 HISTORY Key 1 8 History Memor...

Страница 403: ... Measuring Lead 3 23 3 28 Memory Test 18 15 Menu Language 17 1 Message and Corrective Action 18 2 Message Language 17 1 MISC Key 1 9 MODE Key 1 7 MODEL Part 1 v Module 3 5 19 44 Module Specification 19 18 Monitor Capture 16 33 Moving Average 2 17 7 9 App 43 Multiplication 2 47 Multiplication DSP Channel 15 3 Multiplication with Coefficient DSP Channel 15 13 Multiplying 10 1 mV V 2 14 N Page Networ...

Страница 404: ... Record Length 2 31 7 3 App 1 App 5 RECORDER Key 1 8 Recorder Mode 2 43 9 4 Recording Format 9 8 Recording Numeric Values 9 14 Rect Rectangular 2 47 10 9 Rectangular App 21 Reference Cycle 6 43 Reference Junction Compensation 2 13 Release Arm 12 2 Repeat 2 44 9 7 Reprinting 9 21 9 23 9 24 Reprinting on the Built in Printer 2 46 RESET Key 1 8 Resolution 6 9 12 17 12 19 Right Side Panel 1 3 RJC 2 13...

Страница 405: ... Setting App 1 Time Base 2 3 5 25 Time of Satisfaction 6 36 Time Out 16 11 16 22 Time Print 9 11 12 11 13 50 Time Reference Mark 6 4 Time Window 10 9 App 21 TIME DIV Knob 1 7 Timer Trigger 2 20 6 13 Title 9 28 13 51 Top Panel 1 1 Transducer Output 2 14 Translucent Mode 8 16 Translucent Mode Display 2 38 Transmission Interval 16 17 Transmission Time 16 17 Transmitting E mail Message 2 60 TRIG IN 14...

Страница 406: ... 8 Web Server 2 60 16 23 Web Server Window 16 27 WebDAV 16 52 Width 6 39 9 10 9 19 12 11 Window 6 39 Window Trigger 2 25 6 37 X Page X Y Recorder Mode 2 46 9 5 X Y Waveform 8 12 X Y Waveform Display 2 40 X Y Waveform Recording 9 17 Z Page Zip Disk 13 2 Zip Drive 19 9 Zone Number 11 47 Zoom 2 41 ZOOM Key 1 8 Zoom Position 5 13 8 11 15 2 Zoom Print 12 9 Zoom Rate 5 13 8 10 Zooming 8 8 Zooming Horizo...