YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
715
□ Able to transmit segmented messages / Window Size:
□ Able to receive segmented messages / Window Size:
•
Standard Object Types Supported:
Object Types
Descriptions
Device Object
Optional Writeable:
–
Max_Info_Frames
–
Max_Master
Analog Input Object
Optional properties supported:
–
COV_Increment
Optional Writeable:
–
COV_Increment - supported on various instances
Analog Output Object
-
Analog Value Object
Optional properties supported:
–
COV_Increment
Optional Writeable:
–
COV_Increment - supported on various instances
Binary Input Object
-
Binary Output Object
-
Binary Value Object
-
•
Data Link Layer Options:
□ ARCNET (ATA 878.1), 2.5 Mb. (Clause 8)
□ ARCNET (ATA 878.1), EIA-485 (Clause 8), baud rate(s):
□ BACnet IP, (Annex J)
□ BACnet IP, (Annex J), BACnet Broadcast Management Device (BBMD)
□ BACnet IP, (Annex J), Network Address Translation (NAT Traversal)
□ BACnet IPv6, (Annex U)
□ BACnet IPv6, (Annex U), BACnet Broadcast Management Device (BBMD)
□ BACnet/ZigBee (Annex O)
□ Ethernet, ISO 8802-3 (Clause 7)
□ LonTalk, ISO/IEC 14908.1 (Clause 11), medium:
■ MS/TP master (Clause 9), baud rate(s): 9600, 19200, 38400, 76800
□ MS/TP slave (Clause 9), baud rate(s)
□ Point-To-Point, EIA 232 (Clause 10), baud rate(s):
□ Point-To-Point, modem, (Clause 10), baud rate(s):
□ Other:
•
Device Address Binding:
Is static device binding supported? (This is currently necessary for two-way communication with MS/TP slaves and
certain other devices.) □Yes ■No
•
Networking Options:
□ Router, Clause 6 - List all routing configurations, e.g., ARCNET-Ethernet, Ethernet-MS/TP, etc.
□ Annex H, BACnet Tunneling Router over IP
•
Character Sets Supported:
Indicating support for multiple character sets does not imply that they can all be supported simultaneously.
■ ISO 10646 (UTF-8)
□ IBM/Microsoft DBCS
□ ISO 8859-1
□ ISO 10646 (UCS-2)
□ ISO 10646 (UCS-4)
□ JIS X 0208
•
Gateway Options:
If this product is a communication gateway, describe the types of non-BACnet equipment/networks(s) that the
gateway supports:
Not supported
Содержание H6B1A002
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...