YASKAWA
SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference
661
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
Y4-42
(3D23)
Output Disconnect
Detection Sel
This parameter applies only when in Drive Mode. It sets the drive response if the
connection between the drive and the motor is disconnected.
0 : Disabled
1 : Alarm - Speed Search
2 : Alarm - Start at Zero
3 : Fault
Note:
1.
Loss Of Load
[Z1-31 to Z1-36]
, Load Verify
[Z1-53]
, and Bypass Energy Savings
[Z1-16]
can interfere with the correct operation of Output Disconnect Detection.
2.
When the Output Disconnect is active, the drive internally disables Output Phase
Loss Detection of more than one phase.
0
(0 - 3)
Y4-43
(3D24)
Output Disconnect Inject
Current
Sets the level of DC injection current during output disconnect as a percentage of the drive
rated current.
30%
(5 - 50%)
◆
YA: Preset Setpoint
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
YA-01
(3E58)
RUN
Setpoint 1
Sets the PID Setpoint when
b1-01 = 0 [Frequency Reference Selection 1 = Keypad or
Multi-Speed Selection]
.
Note:
Parameters
b5-46 [PID Unit Display Selection]
,
b5-38 [PID User Unit Display
Scaling]
, and
b5-39 [PID User Unit Display Digits]
set the unit, range, and resolution.
0.00
(0.00 - 600.00)
YA-02
(3E59)
RUN
Setpoint 2
Sets the PID Setpoint as specified by the Multi-Setpoint digital inputs.
Note:
Parameters
b5-46 [PID Unit Display Selection]
,
b5-38 [PID User Unit Display
Scaling]
, and
b5-39 [PID User Unit Display Digits]
set the unit, range, and resolution.
0.00
(0.00 - 600.00)
YA-03
(3E5A)
RUN
Setpoint 3
Sets the PID Setpoint as specified by the Multi-Setpoint digital inputs.
Note:
Parameters
b5-46 [PID Unit Display Selection]
,
b5-38 [PID User Unit Display
Scaling]
, and
b5-39 [PID User Unit Display Digits]
set the unit, range, and resolution.
0.00
(0.00 - 600.00)
YA-04
(3E5B)
RUN
Setpoint 4
Sets the PID Setpoint as specified by the Multi-Setpoint digital inputs.
Note:
Parameters
b5-46 [PID Unit Display Selection]
,
b5-38 [PID User Unit Display
Scaling]
, and
b5-39 [PID User Unit Display Digits]
set the unit, range, and resolution.
0.00
(0.00 - 600.00)
◆
YC: Foldback Features
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
YC-01
(3EBC)
Output Current Limit
Select
Sets the function to enable or disable the output current regulator.
0 : Disabled
1 : Enabled
0
(0, 1)
YC-02
(3EBD)
RUN
Current Limit
Sets the current limit.
Note:
Value is internally limited to 300% of the drive rated current set in
n9-01 [Inverter
Rated Current]
.
0.0 A
(0.0 - 1000.0 A)
◆
YF: PI Auxiliary Control
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
YF-01
(3F50)
PI Aux Control Selection
Sets the PI Auxiliary Control function.
0 : Disabled
1 : Enabled
0
(0, 1)
YF-02
(3F51)
RUN
PI Aux Control
Transducer Scale
Sets the full scale (10 V or 20 mA) output of the pressure transducer connected to the
analog input terminal programmed for
H3-xx = 27 [PI Aux Control Feedback Level]
.
Note:
Parameters
YF-21 [PI Aux Ctrl Level Unit Selection]
and
YF-22 [PI Aux Level
Decimal Place Pos]
set the unit and resolution.
145.0
(1.0 - 6000.0)
Содержание H6B1A002
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 12: ...12 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 30: ...1 2 Catalog Code and Nameplate Check 30 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 68: ...2 9 Knock Out Hole Dimensions 68 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 74: ...Page Intentionally Blank...
Страница 76: ...Page Intentionally Blank...
Страница 454: ...5 14 Z Bypass Parameters 454 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 590: ...8 6 Storage Guidelines 590 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 694: ...9 19 Defaults by Bypass and Drive Model 694 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 768: ...10 6 MEMOBUS Modbus Communications 768 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...
Страница 780: ...11 3 European Standards 780 YASKAWA SIEPYAIH6B01A HV600 AC Drive Bypass Technical Reference...