For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
56/273
(11) Teaching Start
Put the double-sided tape onto the required material "BARON PCB" as shown in the
photo and set it on the transfer supply position. Then, press the teaching start button
on the window. The automatic adjustment will be started.
Note:
Before putting the double-sided tape, clean the surface of "BARON PCB" using soft cloth. After the
cleaning, check that there is no dirt on the PEC recognition mark. If there is any debris, dust or dirt,
a
measurement error might be caused.
When the double-sided tape is to be put, put it so that any bubble is not left between the board and
the
tape. Such bubble might cause a measurement error.
Fig. A52
Fig. A53