For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
178/273
4.16.4. Cutter Unit Operation Check
(1)
Start up the machine and connect the feeder cart to the machine using the connectors.
(2)
Select
"
Maint.
"
and
"
Engineer
"
to display the initial maintenance window.
(3)
Touching the window in the order as shown in the following figure, the use of the
"
Debug
"
window is enabled.
* Refer to the following figure for the
"
Debug
"
display procedure.
Fig.D103
"Debug" is displayed and when the "Unit
Adj." is selected, the functions in the red
frame become available.
Normally, only "Noz Chng" and "Line
Meas" functions are available.
①
. Hold the section
①
. down until a single green
circle appears in the area
⑥
.
②
. After the green circle has appeared, hold the
section
②
down until three green circles
appear in the area
⑥
.
③
. When three green circles appear, hold the
section
③
down. Then,
④
will appear.
④
. After
④
has appeared, touch the area
⑤
.
The debug mode will be displayed.