For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
47/273
1.4.5.13.
Self-Calibration Placement Condition
Set the placement pattern to the optimum condition placement and adjust the head offset.
<Placement Accuracy Standard Values>
(1) 90,000 CPH Operations (For High-Speed Head)
(
ⅰ
) X/Y Standard Value (Placement Deviation) <General results of Two High-Speed Heads>
Total
For Each Angle (0,90,180,270)
3σ
:
40
(μm) or less
40
(μm) or less
CPK
:
1.0 or more (±SL
:
40
μm)
1.0 or more (±SL
:
4
0μm)
MAX/MIN
:
40
(μm) or less
40
(μm) or less
(
ⅱ
)
θ Standard Value (Inclined Placement) <Results of Two High-Speed Heads>
Total
For Each Angle (0,90,180,270)
3σ
:
5.0 (deg) or less
CPK
:
1.0 or more (±SL
:
5.0deg)
MAX/MIN
:
5.0 (deg) or less
<Placement Conditions>
(1)
PCB Finishing Position: Downstream Position
(2)
Self-Calibration Function Description for Each machine
No
Large Item
Item
Σ-G5S
Σ-G5S
II
Σ-F8
1
Self-Calibration Applicable
Head
High-Speed head
○
○
○
Multi-functional head
×
×
-
2
Head Offset Preparation
(Only for High-Speed Head)
Head offset A
○
○
○
Head offset B
○
○
○
For each head offset angle
○
○
○
For each head offset NL speed reduction
○
○
○
Offset automatic correction function
×
×
×
3
CPK Placement Result
Display
Screen Display
○
○
○
Placement Result Save Function
×
×
×
4
Machine Configuration
PP Automatic Switching
○
○
○
5
PP Preparation List for Each
Self-Calibration Machine
Option
Single Transfer Front Reference LR
○
○
○
Single Transfer Front Reference RL
○
○
○
Single Transfer Rear Reference LR
○
○
○
Single Transfer Rear Reference RL
○
○
○
Dual Transfer Front Reference LR
×
×
-
Dual Transfer Front Reference RL
×
×
-
Dual Transfer Rear Reference LR
×
×
-
Dual Transfer Rear Reference RL
×
×
-
Long PCB Transfer Front Reference LR
×
×
-
Long PCB Transfer Front Reference RL
×
×
-
Long PCB Transfer Rear Reference LR
×
×
-
Long PCB Transfer Rear Reference RL
×
×
-
6
Linkage with NT-100
Placement Result Captured by NT
×
×
×
Offset Correction in NT-100
×
×
×
7
Additionally Requested
Function
NG point manual measurement
Management Information Message in Offset Clear
Operation
Change of Component to be placed