For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
163/273
(10) After cleaning is completed, wipe off alcohol or give it time to air dry. Then, apply
grease (Daphne Eponex No. 1) the retainer section (one location, 2 lines) so that the
grease amount as much as half size (0.03g) of a match head is applied to each
location. (Grease should be applied to all 15 locations).
* When the air is blown into the retainer inside to dry it, take care not to lose the V-
packing.
* Use something like a bamboo skewer as a tool for applying grease. Do not use an
cotton applicator or tooth pick which leaves fiber residue or small piece of wood.
Fig.D78