For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
157/273
(2) Remove the linear measure sensor light projector.
Remove the two M1 and 6L4 bolts (shown in the yellow section in the following figure)
and pull out the linear measure.
* Because the bolt to be removed has been fixed using Screw Lock (1401B), the
greatest care is required.
* Do not reuse any removed screw.
Fig.D68
Separate the linear measure sensor from the pulled out linear measure sensor
connector section.
* When the linear measures are pulled out, confirm the direction of each of the linear
measures.
This is because they are returned in the direction same as before when they are
attached.