For the Head Section Selected Axis Home Return
When the NS-axis or DD-axis is to be zeroed, make sure to zero the NL-axis first. In the case that the
NL-axis is not at the home position and the NS-axis or DD-axis is moved, the machine might be broken.
2.3. Nozzle Change Procedure
There are two ways for the nozzle change.
[1] Select "Setup" and "No2. Chg." in this order and perform the nozzle change in the
"NOZ.CHG" window.
: For All Nozzle Attachment based on the pattern program or All Nozzle Housing
[2] Select "Maint. ", "Unit Adj." and "NOZ.CHG" in this order and perform the
nozzle change in the "NOZ.CHG" window.
: For Individual Nozzle Attachment or Housing selected and decided by the
operator. Each way is described in details as follows.
2.3.1. Nozzle Change Procedure in the "Setup" window.
(1)
Housing the Nozzle in the Stocker
In the "Setup" window, select
"Change". Then, select the subject
head and "Reset" and press the
"Move" button and press the
[START] button on the operation
panel.
(2)
Placing the Nozzle onto the Head
Select the subject head and
"Change"
and press the
"Move" button and
press the [START] button on the
operation panel.
Do not move the NS or DD-axis.
The NL-axis is not at the home position!