For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
37/273
1.4.5.8. Head Rotation Center/Base Mark Position Teaching
Under each of the following conditions, this teaching is required.
It affects the placement accuracy directly.
The in-house adjustment is to be performed.
The offset teaching is to be performed when
the machine is delivered.
The head has been changed.
The PEC recognition camera is to be changed.
The component recognition camera is to be changed.
X-axis or Y-axis linear scale and scale head are to be changed.
Required Jig and Tool
QFP Glass Jig
: JG-0188 1 unit
Vacuum Nozzle : HA19C 1 unit
Purpose (Head Rotation Center Offset)
The deviation from the designed value for the distance from the head rotation center to
the PEC recognition camera center is adjusted.
Fig.A32-1
QFP Glass Jig
JG-0188
Fig. A32-2