For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
108/273
(6)
After the position adjustment, check the following items and if there is no problem,
tighten the setscrews completely.
Scale Head Adjusting Jig (t = 0.3mm): It can pass through.
Scale Head Adjusting Jig (t = 0.5mm): It cannot pass through.
Note:
Basically, the position adjustment is performed only at one location.
(It is because the final adjustment is performed using the software (PC)).
Note:
Finally, check the following items and if
there is no problem, fix it. Then, adjust the
parameters.
1. The scale head jig with thickness
0.3mm can be entered without problem.
2. The scale head jig with thickness
0.5mm can not be entered.
Fig.C46