For Service Engineer
Service Information
SI1705004E-00=SIGMA-G5SII Service Manual
88/273
3.1.4.4. Multi - None - High - High
The nozzle stockers for high-speed nozzle are added to the nozzle stocker unit for multi-
functional nozzle.
Note:
(1) Connect the nozzle stockers as shown in the following figure.
Set the Up-Status Detection Sensor for the Nozzle Stocker Unit for Multi-Functional Nozzle to
"
AND
"
.
(2) Because the print mark for the connectors for the nozzle stocker addition valves is only
"
XUP
"
,
mark
"
3
" and "4" additionally
on the connectors using a magic pen, etc., as shown in the
following figure.
(3) The shutter valve (for addition) for the nozzle stocker for high-speed nozzle functions for the shutter
open/close operation for the high-speed nozzle stocker for to be added.
Fig.C9