background image

Accublock Digital Dry Bath 

User Manual

Copyright 2017

D1301 D1301-230V

D1302 D1302-230V

D1304 D1304-230V

Содержание Accublock D1301

Страница 1: ...Accublock Digital Dry Bath User Manual Copyright 2017 D1301 D1301 230V D1302 D1302 230V D1304 D1304 230V...

Страница 2: ...Italian Portuguese and Spanish on our website at www labnetinternational com Labnet International s single and dual Dry Bath Incubators provide comprehensive designs for a wide variety of life scienc...

Страница 3: ...1 3 0 Getting Started 2 3 1 Unpacking 2 3 2 Initial Operation 2 4 0 Controls 2 4 1 Keypad Function 2 5 0 Operation 3 6 0 Calibration 4 7 0 USB Interface 5 8 0 Troubleshooting Guide Service 5 8 1 Servi...

Страница 4: ...If the digital dry bath is used in a manner not specified by the manufacturer the protection provided by the centrifuge may be impaired...

Страница 5: ...ct in any manner not specified by this instruction manual may cause injury and or may void the warranty If the equipment is used in a manner not specified by the manufacturer the protection provided b...

Страница 6: ...grounded outlet Using the lifter insert the block s into the well The unit is now ready for use 4 0 Controls On Off rocker switch Located on back of unit Turns primary power on and off Start Stop LED...

Страница 7: ...tor 4 Turn the AC power ON 5 Run temperature calibration procedure when using the instrument for the first time 6 Press or Key to adjust to the desired temperature 7 Press or Key to adjust to the desi...

Страница 8: ...ch If not repeat the calibration procedure 7 Upon completion of the calibration procedure turn unit off and on again to re set desired time or continuous time Thermometers used for calibration purpose...

Страница 9: ...ermometer making good contact 5 Follow calibration procedure e Factory Reset User can long press two temperature buttons for factory reset unit will display message once completed if reset successfull...

Страница 10: ...unit upside down to minimize liquid contact with the internal components Remove the bottom cover and inspect to assure liquid has not contacted heater elements electronic controls or connectors Have q...

Страница 11: ...AccuBlock Digital Dry Bath 7...

Страница 12: ...tor brushes fuses light bulbs batteries or damage to paint or finish Claims for transit damage should be filed with the transportation carrier ALL WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANT...

Страница 13: ...Corning Incorporated 271 County Route 64 Big Flats NY 14814 www labnetinternational com labnetinfo corning com...

Отзывы: