726
JD700B Series User’s Guide
3
Press the
MEASURE SETUP
hot key.
4
Toggle the
Select RRH
soft key between
Port1
and
Port2
to select a RRH to check the
spectrum.
5
To set the Rx parameters, complete the following steps:
Press the
Rx Parameters
soft key.
Press the
Rx Carrier
soft key, and then select the carrier of your choice.
Only carriers that are currently available have the active soft keys.
Up to 12 selections for carriers are available based upon configuration.
Press the
Rx Container
soft key, and then select the Rx container of your choice.
Up to 4 selections for containers are available based upon configuration.
Optional.
To set the bandwidth, press the
Bandwidth
soft key, and then select the
bandwidth option from:
1.4 MHz
,
3 MHz
,
5 MHz
,
10 MHz
,
15 MHz
,
15 MHz (4AxC)
,
20 MHz
,
or
20 MHz (6 AxC)
.
6
To set the CPRI source, complete the following steps:
Press the
CPRI Source
soft key.
Select the Tx number from: Tx1 Parameters, Tx2 Parameters, Tx3 Parameters, or Tx4
Parameters.
Press the
Tx Carrier
soft key, and then select the carrier of your choice.
Only carriers that are currently available have the active soft keys.
Up to 12 selections for carriers are available based upon configuration.
Press the
Tx Container
soft key, and then select the Tx container of your choice.
Up to 4 selections for containers are available based upon configuration.
Optional.
To set the gain, press the
Gain
soft key, and then enter a value by using the
rotary knob or the numeric keys.
Optional.
To set the waveform to be generated, press the
Waveforms
soft key, select a
signal from the Waveform dialog box, and then tap the
Apply
button or press the
ENTER
hard key.
Optional.
To set the power level, press the
Power Level
soft key, enter a value by using the
numeric keys or the rotary knob, and then press the
Enter
soft key or the
ENTER
hard key.
To start injecting the signal, toggle the
CPRI Source
to
On
.
7
To clear current (C) and history (H) status of CPRI alarm on LOS and LOF, press the
MEASURE
SETUP
hot key, the
More (1/2)
soft key, and then the
Clear History
soft key.
Checking flatness
The flatness in Wideband Mode PIM analysis is an elevation angel that two points create, resulting from the
difference in power level at the two ends.
Procedure
1
Press the
BBU Emulation > Alcatel-Lucent
soft key.
2
Select PIM Analysis > Multi Port Wideband Mode.
3
Press the
MEASURE SETUP
hot key.
4
Select the
Flatness
soft key.
5
To set the bandwidth for the flatness calculation, complete the following steps:
Press the
Bandwidth
soft key.
Enter a value that is smaller than the transmission bandwidth to prevent the spectrum data
points from being at the edges of the chart.
6
Toggle the
Flatness
soft key to
On
.
7
To turn it off, toggle the
Flatness
soft key to
Off
.
Setting sweep mode
You can select various sweep settings for better measurement, including the sweep run mode (
Single
,
Continuous
) and the sweep speed mode (
Normal
,
Fast
).
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...