Chapter 9
Using LTE-TDD Signal Analyzer
JD700B Series User’s Guide
323
2
Press the
Settings
soft key and then set the following;
Press the
Bandwidth
soft key and then select the nominal channel bandwidth to be
measured from the choices:
1.4 MHz
,
3 MHz
,
5 MHz
,
10 MHz
,
15 MHz
, and
20 MHz
.
Press the
MIMO
soft key, and then select the antenna number option:
2x2
or
4x4
.
This MIMO (Multiple Input Multiple Output) setting is activated only if the option 031 LTE-
Advanced TDD is installed with a license number. If not, the instrument sets this option to
2x2 by default. A 2x1 or 4x1 RF combiner is also required to able to test on MIMO
channels.
Toggle the
Physical Cell ID
soft key and select
Auto
or
Manual
as desired:
Auto:
Lets the instrument detect the Physical Cell ID for the LTE signal automatically.
Manual:
Sets a specific Physical Cell ID for the LTE signal manually in order to speed
up the synchronization with a BTS.
Press the
Antenna Port
soft key, and then select the option:
Auto
,
0
,
1
,
2
, or
3
.
If the option 031 LTE-Advanced TDD is not installed or if the MIMO is set to 2x2, the
antenna ports 2 and 3 are disabled.
Toggle the
External Offset
soft key and select
On
to set the external offset value.
To turn the Multimedia Broadcast Multicast Service (MBMS) feature on or off, toggle the
MBMS
soft key and select
On
or
Off
.
To set the Multicast Broadcast Single Frequency Network (MBSFN) detection automatically
or manually for MBMS testing, toggle the
MBSFN
soft key and select
Auto
or
Manual
. An
automatically detected or manually entered MBSFN ID appears on the screen.
3
To save your settings, go to
SAVE/LOAD > Save > Save Setup
and then perform functions as
you desire. See “Using save” on page 35 for more information.
4
Press the
Continue
soft key to do the reference test first or press the
Skip Reference Test
soft
key if you already saved test results from the radio band under test.
5
Press the
FREQ/DIST
hard key and then set the frequency to be measured. See “Setting
frequency” on page 284 for more information.
6
Press the
PREV
hard key.
7
Press the
Limit
soft key and then set the limits and allowed percentage change for each test
item. See “Maintenance test” on page 319 for more information on setting limits.
8
Keep pressing the
PREV
hard key until you see the Run Test soft key.
9
Press the
Run Test
soft key.
The instrument runs specified tests to gather reference measurement values. The measurement
table appears when the reference test is done.
10
Press the
Continue
soft key to run the testing on an antenna (Ant 1).
11
Optional
. To change the settings such as
External Offset
, press the
Settings
and then change
the settings as needed.
12
Press the
Continue
soft key.
The instrument runs the testing on Ant 1. The Ant 1 tab appears with the updated result table
when the test is done.
13
To run the testing on the next antenna (Ant 2), press the
Run Test
soft key and then repeat the
steps
11-12
. You can do the testing on up to 10 distributed antennas for one radio band.
14
To view test results for each antenna, press the
Select Antenna
soft key and then select the
antenna tab number to display on the screen.
15
Optional
. Press the
Delete
Test soft key to delete the selected antenna tab.
16
Optional
. Press the
Retest Reference
soft key to obtain reference measurement values again.
17
Optional
. To save your measurement results, go to
SAVE/LOAD > Save
and then perform
functions as you desire. See “Using save” on page 35 for more information.
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...