Chapter 19
Using Channel Scanner
744
JD700B Series User’s Guide
Analyzing measurements
Setting limit for channel scanner
Procedure
To use the display line:
1
Press the
LIMIT
hot key.
2
Press the
Display Line
soft key to set a threshold for the limit line and Pass/Fail indication.
3
Enter a value, and then press the
dBm
unit soft key.
4
Toggle the
Display Line
soft key between
On
and
Off
to display or dismiss the limit line.
To use the channel limit:
1
Press the
LIMIT
hot key.
2
Press the
Channel Limit
soft key to set the limits for each channel index.
3
Press the
Index
soft key, and then select the channel/frequency index number by turning the
rotary knob or using the numeric keys.
4
Toggle the
Limit
soft key between
On
and
Off
to enable or disable the Pass/Fail indication.
5
Set the upper threshold:
Press the
High Limit
soft key.
Enter a value for the upper limit.
Press the
dBm
unit soft key.
6
Set the lower threshold:
Press the
Low Limit
soft key.
Enter a value for the lower limit.
Press the
dBm
unit soft key.
7
Optional
. Go to
SAVE/LOAD > Save
, and then select the save option from the choices available
for your measurement mode. See “Using save” on page 35 for more information.
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...