NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See “Setting limit for RF tests” on page 401 for more
information.
Multi-ACPR
The Multi-ACPR measurement is used to perform multi-channel ACPR measurements with as many
channels as possible. It helps you to measure ACPR in multi-channel transmitting Base Station environment.
Setting frequency for Multi-ACPR
You can set the frequency with either frequency or channel number.
Procedure
1
Press the
MEASURE SETUP
hot key.
2
To set the frequency, do one of the following:
To set the center frequency, complete the following steps:
Toggle the
Unit
soft key and select
Freq
.
Press the
Lowest Frequency
soft key to set the starting center frequency.
Enter a value by using the numeric keys. You can also use the rotary knob.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
Press the
Highest Frequency
soft key to set the stopping center frequency.
Enter a value by using the numeric keys. You can also use the rotary knob.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
To set the channel number, complete the following steps:
Toggle the
Unit
soft key and select
Channel
.
To select the standard channel, press the
Channel Std
soft key and then select the
band to be measured.
Press the
Lowest Channel
soft key to set the starting channel.
Enter a value by using the numeric keys. You can also use the rotary knob.
Press the
Enter
soft key.
Press the
Highest Channel
soft key to set the stopping channel.
Enter a value by using the numeric keys. You can also use the rotary knob.
Press the
Enter
soft key.
After configuring the test parameters, your measurement result is displayed on the screen as like the
following example,
Содержание CellAdvisor JD700B Series
Страница 2: ...CellAdvisorTM JD700B Series FW3 120 User s Guide ...
Страница 105: ...Chapter 4 Using Spectrum Analyzer 104 JD700B Series User s Guide Figure 44 PIM detection for multiple carriers ...
Страница 406: ...Chapter 11 Using EV DO Signal Analyzer JD700B Series User s Guide 405 3 Pilot 4 MAC 64 5 MAC 128 ...
Страница 734: ...Chapter 18 Perfroming BBU Emulation JD700B Series User s Guide 733 Figure 441 Example of verification of link status ...
Страница 763: ...Chapter 21 Performing Fiber Inspection 762 JD700B Series User s Guide Figure 461 Fiber inspection report ...
Страница 808: ...Appendix JD700B Series User s Guide 807 JD740B series ...
Страница 811: ...Appendix 810 JD700B Series User s Guide Figure 470 Append keywords window ...